MOS mentioned in column No. 4, 5 and 6 are minimum. In case of industrial building of more than one floor, Front MOS shall be equal to half of the proposed height of building, similarly side MOS shall be equal to one third of the proposed height of building.
The State Government may relax above norms on the recommendation of the Industries Department after considering the merits of case.
Hazardous Industries / Polluting Industries or Industries which require sanction under Factory Act, clearances shall have to obtained under Industrial Health and Safety and/or under Environment Protection Act as the case may be.
1[4. Development norms for standalone Industrial buildings shall be as follows:-
Norms for Standalone Industrial buildings
Sr. No.
Land Area
Max. Ground Coverage in %
Minimum MOS in meters
Max. Floor Area Ratio (FAR)
Front
Side/Side
Rear
(1)
(2)
(3)
(4)
(5)
(6)
(7)
1
0.50 Hect. and upto 0.75 Hect.
75
10.00
4.50/4.50
4.50
1.00
2
More than 0.75 Hect. and upto 1.00Hect.
75
12.00
5.00/5.00
6.00
1.00
3
More than 1.00 Hect. and upto 1.25 Hect.
75
15.00
6.00/6.00
7.50
1 00
4
More than 1.25 Hect. and upto 2.00 He Ct.
75
15.00
7.50/7.50
7.50
1.00
5
More than 2.00 Hect.
75
21.00
9.00/9.00
9.00
1.00
For Flatted Industries
6
Minimum Land Area 1500 sq.m. (0 15 Hect.)
50
12.00
6.00/6.00
6.00
2.00
1Inserted by Notification No. F. UDH-3/0002/18-5/2024 dated 0 6 t h March 2025.
Published in M.P. Rajpatra (Asadharan) S.N. 72 dated 06th March 2025 at pages 144-144(2).
Rule 49
65
Note :-
The Note mentioned in sub-rule (3) of rule 48 shall be applicable here.]
Other Amenities.- (1) In addition to common open spaces, the layouts shall provide for the minimum community facilities as laid down in Table 6 :-
TABLE 6
[See Rule 49(1)]
COMMUNITY FACILITIES AND OTHER SUB-DIVISIONAL REQUIREMENTS
S. No.
Facilities required
Scale of minimum provision
Minimum land area required and remark
Main type
Sub-type
(1)
(2)
(3)
(4)
(5)
1.
Educational Facilities
Nursery School (3 to 5 age group)
1 for population of 4000
1.0 hectare.
Primary School (5 to 11 age group)
1 for population of 4000
0.6 hectare for density up to 250 persons per hectare
0.5 hectare for density from 251 to 500 persons per hectare
0.4 hectare for density of 501 persons per hectare and above
Educational Facilities
High School (11 to 16 age group)
1 for population of 16,000
2.0 hectares for density up to 250 persons per hectare
1.8 hectares for density from 251 to 500 persons per hectare
Degree College
1 for population of 80,000
4 to 6 hectares
Rule 49
2.
Health Facilities
Health Center
1 for population of 16,000
1.0 hectare with residential staff quarters
General Hospital
1 for population of 80,000
4.0 hectare for 200 beds with ancillaries and staff quarters
3.
Commercial facilities including shopping facilities
Convenience shop
1 for a population of every 100
0.05 to 0.1 hectare
Local shopping centre
1 for population of 16,000
0.4 hectare
Zonal shopping centre
1 for population of 80,000
2.5 hectare
4.
Communicat ion facilities and essential services
Sub-post office
1 for population of 10,000
100 square meters
Post and Telegraph Office cum Delivery and Booking including Telephone exchange of 1000 lines.
1 for population of 10,000
1.0 hectare
Electric Sub-station
1 in all shopping centers
12 meters x 12 meters
Communicat ion facilities and essential services
Police Station with Staff quarters
1 for population of 50,000
0.8 hectare
Police post with staff quarters
1 for population of every 20,000
0.4 hectare
Fire Station with staff quarters
1 for every 5 kilo-meter radial distance
0.8 hectare
Rule 49
67
5.
Social and Cultural Facilities
Religious building
1 for population of every 15,000
0.8 hectare location not on a intersection of roads and 60 meters away from junctions.
Community Hall and library
1 for population of every 15,000
0.3 hectare
Cinemas
1 for population of every 25,000
0.3 hectare with parking location in Zonal shopping centers, business and commercial area not in residential zone or at the rate of 3 sq.m. per seat whichever is more.
6.
Facilities for industrial area
Labour Welfare Center
1 for every 40 hectare
0.2 hectare
Convenience shops
5 shops of 10 square meters each
0.2 hectare
Health center
1 for every 200 hectare
0.6 hectare
Post Office
0.04 hectare
Telephone exchanges
0.06 hectare
Bank
200 square meters
Petrol pump cum-service-station
30 meters x 35 meters
Police Station with Staff quarters
0.4 hectare
Fire station with staff quarters
0.8 hectare
Note: (1) The minimum land required for various amenities mentioned in column 5 above is only indicative. The size of the plot shall be, as may be prescribed, by the administrative department or any regulatory authority or any other authority competent to prescribe the minimum size of plot. This table shall stand modified accordingly.
Rule 50
68
(2) The requirements of essential amenities for EWS and Low Income Group Housing shall be as given in Appendix-J.
(3) Table 6 shall be the guideline to workout different requirements of sub division or layout plan. The density proposed in the Development Plan shall determine the actual population of an area. In areas where a Development Plan or a Zonal Plan has not been prepared, the density pattern for that area shall be determined by the Director.
(4) An application can be made to the Authority on prescribed form as given in Appendix - G to obtain proposals of Development Plan or Zoning Plan for the land to which an applicant may be interested. The Authority shall within thirty days from the date of receipt of such application, supply to the applicant such information, as may be necessary for him to prepare a sub-division or layout plan for his land in accordance with the Development Plan or zoning plan or any proposed land use or density pattern, as the case may be.
Requirements of Site.- No piece of land shall be used as a site for the construction of building, if the,-
(a) Authority considers that the site is insanitary or that it is dangerous to construct a building on it;
(b) site is within a distance of 9 meters of the highest water level of a water body/water course and 15 mtrs. in case of river or as prescribed in the development plan;
(c) owner/applicant of the building has not shown to the satisfaction of the Authority all the measures required to safeguard the construction from constantly getting damp;
(d) building is for assembly use like cinemas/theaters/public worship, and the applicant has not obtained necessary license or clearance from the competent officer of the concerned Authority;
(e) building is proposed in an area filled up with carcasses, excreta filthy and offensive matter till the production of certificate from local authority to the effect that it is safe from the health and sanitary point of view and is fit to be built upon;
(f) site is not drained properly or is incapable of being well drained;
(g) site will be used for the purpose which in the opinion of the Authority will be a source of annoyance to the health and comfort of the inhabitants of the neighborhood;
(h) plot has not been approved as a building site;
Rule 51-52
69
(i) proposed occupancy of the building on the site does not conform to the land use proposals in the development plans or zoning regulations;
(j) building adversely affects any public utility like a Municipal drain/sewer line or water main line or transmission line.
1[(k) If the site is within 30 meters of the railway premises, then the restricted distance shall apply only with reference to the railway station or railway limit along railway line. This may be relaxed with prior consent of the Railway Department.]
Surface Water Drains.- (1) Any land passage or other area within the cartilage of a building shall, if the Authority so requires, be effectively drained by surface water drain or other means.
(2) The written approval of the Authority shall be obtained for connecting any sub-soil drain to a sewer.
Distance from electric lines.- (1) The minimum distance between the building and any overhead electric supply line shall be as mentioned herein below or that mentioned in the applicable Electricity Rules, whichever is more. No verandah, balcony or the like shall be allowed to be erected or re-erected or any additions or alterations made to a building which violates this rule.
S.No.
Particulars
Vertically meters
Horizontally meters
(1)
(2)
(3)
(4)
(a)
Low and Medium voltage lines and service lines
2.5
1.2
(b)
High voltage lines up to and including 33000 volts
3.7
1.2
(c)
Extra high voltage lines beyond 33000 volts
(see note)
Note: For building close to extra high voltage lines beyond 33000 volts, clear horizontal corridor of 15 meters (7.5 meter open both side of centre line), or as specified in the applicable Electricity Rules, whichever is more, shall be provided.
(2) The minimum clearance specified in sub-rule (1) above shall be measured from the maximum sag for vertical clearance and from maximum deflection due to wind pressure for horizontal clearance.
Inserted by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025.
Published in M.P. Rajpatra (Asadharan) S.N. 73 dated 06th March 2025 at pages 145-146(1).
Rule 53
70
Part IVDevelopment Control
Land use classification.- The land uses shall be broadly classified as indicated below :-
S.N.
Land Use Zone
Land Use Sub-Zones
Nomenclature
(1)
(2)
(3)
(4)
1.
Residential
Residential
(R1)
Residential with shop lines at Ground Floor medium density low density
(R2)(R3)(R4)
2.
Commercial Zone
City centre
(C1)
Sub city centre
(C2)
Community Centre
(C3)
Local Shopping Centre
(C4)
Convenience Shopping Centre
(C5)
Mandi
(C6)
Categorized Markets
(C7)
3.
Industrial Zone
Service Markets
(I1)
General Industries
(I2)
Special Industries
(I3)
Rule 36
4.
Recreation
Parks
(G1)
Green Belts or Afforested area
(G2)
Regional Parks (Zoological or Botanical Parks)
(G3)
Preservation of Natural Areas or Landscape Areas
(G4)
Play Grounds
(G5)
Stadiums
(G6)
Lake Front Development
(G7)
Exhibition Grounds
(G8)
5.
Public & Semi-public
Public Institutions and Administrative Area / Education and Research / Health / Social / Cultural Institutional activities
(P)
6.
Special Purpose
Tourism Promotion Zone
(SP1)
Conservation Zone
(SP2)
Dry Port or Container Depots
(SP3)
Oil Depots or Inflammables goods Depots
(SP4)
Building Material Yards
(SP5)
Obnoxious Industries
(SP6)
SEZ
(SP7)
Mining Areas
(SP8)
Reserved Forest or National Parks or Wild Life Sanctuaries
(SP9)
Others
(SP10)
Rule 36
7.
Transportation
Bus-Stands or Terminus
(T1)
Bus Pick-up Stations
(T2)
Roads
(T3)
Railway Stations
(T4)
Railway Lines
(T5)
Bus Depot
(T6)
Transport Nagar
(T7)
Helipads / Airport
(T8)
Metro Rail Stations
(T9)
8.
Public Utilities and Facilities
Water Treatment Plants
(PUF1)
Sewerage Treatment Plant / Oxidation ponds
(PUF2)
Electric Sub-stations
(PUF3)
Trenching Grounds
(PUF4)
Trunk line Corridor Water/Sewer/Extra Voltage Electric Lines/Gas or Oil Pipe Lines and related structures
(PUF5)
Radio / TV Stations
(PUF6)
Telephone Exchange
(PUF7)
Fire Control Stations
(PUF8)
Solid waste Disposal Plants / Decomposition Plans
(PUF9)
9.
Water bodies
River
(W1)
Lakes / Ponds / Reservoirs
(W2)
Nallah / Canal
(W3)
Flood affected areas
(W4)
10.
Agriculture
Agriculture lands
(A1)
Village abaadi extension
(A2)
Rule 37-38
55
(1) Use premises permitted in land use classifications.- Subject to other provisions of this rule following Industries are permitted in Residential R 1 , R 2 Zone and Commercial Zones,-
(i) Industries listed in Part-1 Appendix-F may be allowed in Zone R l :
Provided that not more than 5 workers at a time are employed in such industry and it does not employ or use any steam, electricity, oil, water or any other mechanical power:
Provided further that the industries listed at Serial Number 1 to 38 of Appendix-F may be permitted with the use of electric power load of maximum 1.00 K.W.
(ii) Industries listed in Part I and II of Appendix-F may be allowed in R 2 . Zone:
Provided that an industry in Part II uses only electricity with a maximum load of power indicated against each and as per conditions laid down therein;
(iii) Industries listed in Part III of Appendix-F with a maximum power load of 5 K.W. may be allowed in commercial zone, in addition to industries listed in Part I and Part II.
(2) Building use and occupancies to be according to Development plan.- The various building uses and occupancies permitted in the various zones shall be as given in the development plan.
(3) Uses to be in conformity with the zone.- Where the use of building or premises is not specifically designated in the development plan, it shall be in conformity with the zone in which they fall.
(4) Uses as specifically designated in development plan.- Where the use of a site is specifically designated in the Development plan, it shall be used only for the purpose so designated.
(5) Non-conforming uses.- No plot shall be used for any use, occupancy or premises other than that are permitted under these rules or the development plan.
Means of access.- (1) No Building to deprive any other building of means of access.- No building shall be erected so as to deprive any other building of the means of access.
(2) Building/plot to abut on a public/private means of Access.- Every building/plot shall, as far as may be possible, abut on a public/private means of access like streets/roads.
Rule 38
56
(3) Construction of building not to encroach upon an area set apart as means of access.- Every person who erects a building shall not at any time erect or cause or permit to be erected any building which in any way encroaches upon or diminishes the area set apart as means of access required under these rules.
(4) Width of means of Access:
(a) The residential plots shall abut on a public means of access like streets or road. Plots, which do not abut on a street or road, shall have access from spaces directly connected from the street or road. The minimum width for various lengths of means of access shall be as given in Table-3. No development on plots or land shall be permitted unless it is accessible by a public street of width not less than 7.5 meters. Public means of access for economically weaker sections or low-income groups shall be as mentioned in Appendix-J.
TABLE 3WIDTH AND LENGTH OF MEANS OF ACCESS [See Rule 38(4)(a)]
S.No.
Width of means of access in meters
Length of means of access in meters
(1)
(2)
(3)
1.
7.5
150
2.
9.0
250
3.
12.0
400
4.
18.0
1000
5.
24.0
Above 1000
Note: (1) The means of access shall be clear of marginal open spaces.
(2) If the development is only on one side of means of access, the prescribed width of the means of access may be reduced by 0.5 meters.
(b) Other Buildings: For all industrial buildings, theatres, cinema houses, assembly halls, stadium, educational buildings, markets other buildings which attract large crowd, the means of access shall not be less than the following:-
Width of means of
Length of means of
access in meters
access in meters
(1)
(2)
12.0
200
15.0
400
18.0
600
24.0
above 600
Rule 39-40
57
(5) Pathways: The approach to the buildings from road/street or internal means of access shall, as far as may be, through paved pathway which shall not be less than 1.5 meters where the length of such pathway is not more than 30 meters.
(6) Length of means of access: Length of main means of access shall be determined by the distance from the farthest plot (building) to the public street. The length of the subsidiary access way shall be measured from the point of its origin to the next wider road on which it meets.
(7) Authority may require larger width of means of access in general interest. In the interest of general development of an area, the Authority may require the means of access to be of larger width than that required under sub-rule (4).
(8) Boundary of plots in existing built up area to be shifted with reference to control line of street. In areas which are already built up and where the plots face street/means of access less than 4.5 meters in width, the plot boundary shall be shifted from the central line of the street/means of access so as to ensure that the street/means of access achieves a width of 4.5 meters.
Leveling etc. of means of access.- (1) Means of access shall be levelled, metalled, flagged, paved, sewered, drained, channelled, lighted, laid with water supply line and provided with trees for shade to the satisfaction of the Authority. It should be free of encroachment by any structure or fixture so as not to reduce its width below the minimum requirement under sub-rule (4) of rule 38 and shall be maintained to the satisfaction of the Authority
(2) If any private street or any other means of access to a building is not levelled, metalled, flagged or paved, sewered, drained, channeled, lighted or laid with water supply line or provided with trees for shade to the satisfaction of the Authority, it may by written notice require the owner or applicant or occupier of the premises situated in front of or adjoining the said street or other means of access or abutting thereon or to which access is obtained through such street or other means of access to fulfil the aforesaid requirements in such manner, as directed.
(3) If any structure or fixture is set upon a means of access reducing its width below the minimum required, the Authority may remove or cause it to be removed further and recover the expenses so incurred from the owner or owners or occupier.
Access from Highways/Important Roads.- No premises other than highway amenities like fuel pumps, motels shall have an access direct from highways and such other roads as may be specified, from time to time, by the Authority. The portion of such roads on which direct access may be permitted shall be as identified in the development plan. However, this clause shall not be applicable in case of existing development on highways/other roads referred above. These provisions shall however be subject to the
Rule 41-42
58
provisions of the Madhya Pradesh Highway Act, 1936 (XXXIV of 1936) and National Highway Act, 1956 (48 of 1956).
Additional provisions for buildings other than residential buildings.- For building other than residential buildings the following additional provisions of means of access shall be ensured :-
(a) the width of the main street, on which the building abuts shall not be less than 12 meters and one end of this street shall join another street of width not less than 12 meters;
(b) the approach to the building and open spaces on its sides shall be hard surfaced capable of taking the weight of fire engine. The side open space shall be kept free of obstructions and shall be motor-able;
(c) main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5 meters. The entrance gate shall fold back against the compound wall of the premises leaving the exterior access way within the plot free for movement of fire service vehicles. If main entrance at boundary wall is built over, the minimum clearance shall be 4.5 meters.
Additional provisions for buildings with height above 12.5 meters.- (1) Planning Norms for the buildings having height above 12.5 meters and up to 30 meters shall be as given in Table No 4.
TABLE No. 4
[See Rule 42(1)]
12.5 M AND UPTO 30 M IS PROPOSED:
S. No.
Road Width in meters
Minimum plot/land (area in sq.m.)
Frontage in meters
FAR
<sup>1</sup>[GroundCoverage per-centage
Building Height in meters
Front M.O.S. in meters
Sides/ rear in MOS in meters
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
1.
12.0 m. and above
1000 sq. m.
18 m.
1:1.50
-
Up to 18 meters
7.5
6.0
2.
18 m. & above
1500 sq. m.
21 m.
1:1.75
-
Up to 24 meters
9.0
6.0
3.
24 m. & above
2000 sq. m.
30 m.
1:2.0
-]
Up to 30 meters
12.00m.
7.5 m.
Note: [*Deleted*]
In Rule 42, Column no. 6 and Note (1) of Table 4 of sub-rule (1) deleted by MP Rajpatra (Asadharan) No. 74 dated 06-03-2025 at page 147-148(5).
Rule 42
59
(2) For High Rise Buildings as defined in rule 2(38). For high rise building Planning Norms shall be as given in Table No 5.
TABLE No. 5
[See Rule 42(2) above]
DEVELOPMENT NORMS FOR PLOTS / LANDS ON WHICH HIGH RISE BUILDING(S) IS PROPOSED
S. No.
Road Width
Minimum plot/land size (area in sq.m.)
Frontage in meters
FAR
Ground Coverage per-centage
Building Height in meters
M.O.S. Front side in meters
MOS Sides/ rear
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
1.
30 m. and above
2500
30 m.
1:2.25
30
Up to 45 meters
15.00 m.
7.5 m.
2.
36 m. and above
3000
40 m.
1:2.50
30
Up to 60 meters
18.00 m.
9.0 m.
3.
45 m. and above
3500
45 m.
1:2.75
30
Up to 75 meters
21 m.
9 m.
4.
60 m. and above
4000
50 m.
1:3.0
30
Up to 90 meters
24.00
10 m.
5.
75 m. and above
4500
60 m.
1:3.0
30
Above90meters
30.00
12 m.
1[Note:
In commercial use premises of planning areas, the authority may allow maximum FAR of 1:5.0 through utilization of TDR FAR and Premium FAR for serial no. 4 and 5 mentioned in above table.
In commercial use premises under Central Business District and Transit Oriented Development Corridor, the authority may allow maximum FAR of 1:7.0 through utilization of TDR FAR and Premium FAR for serial no. 5 mentioned in above table. Central Business District and Transit Oriented Development Corridor shall be as mentioned in respective development plan.
The rate of premium FAR shall be as may be decided by the State Government.]
1Inserted by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025.
Published in M.P. Rajpatra (Asadharan) S.N. 72 dated 06th March 2025 at pages 143-144(1).
Rule 42
60
(3) For building having height more than 12.5 meters the necessary drawings and details shall be submitted to the Authority incorporating all the fire fighting measures recommended in National Building Code Part-IV. The occupancy permit shall be issued only after ensuring that all fire fighting measures are physically in place.
(4) For all high rise buildings site clearance from Site clearance committee under sub-rule (2) of Rule 12 shall be necessary. After site clearance by the committee, planning permission from the Town and Country Planning and building permission from the Authority shall be necessary.
(5) The approach to the building and open spaces on its all sides shall be as hard as is required to bear the weight of fire engine. The said open space shall be kept free of obstruction and shall be motor-able.
(6) Main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5 meters. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If the main entrance at the boundary wall is built over, the minimum clearance shall be 4.5 meters,
1[42A. Norms for Information Technology.- Information Technology (IT), Information Technology Enables Services (ITES) and Electronic System Design and Manufacturing shall be called Information Technology.
(1) Land required for plot :- Minimum area of plot shall be 3000 sq.m.
(2) Information Technology (Investment) Planning Area :- Such area shall be termed as Information Technology Investment Area which bears a minimum area of 2 Hectare (5 acre) and such area which shall be notified by Science and Technology Department, Madhya Pradesh Government.
(3) Floor Area Ratio (FAR):- Plots for Information and Technology, and in Information and Technology Investment Area shall have maximum FAR of 1:2.50 or maximum FAR permissible in the relevant development plan, whichever is higher :
Provided that if the plot/building situated in the Information Technology Investment Area is being used for non IT purposes in excess of the percentage
Ins. by Notification No. F-3-48/2017/18-5, dated 13th December, 2017. Published in M.P. Rajpatra Part 4(Ga) dated 22nd December, 2017 at pages 666-667.
Rule 43-45
61
mentioned in the following table-5 A, then the FAR and land use of whole plot/building shall be accepted as per the relevant development plan.
TABLE 5-A
[See Rule 42(a)]
Percentage of Plots/Building under MPIT, ITES and ESDM
S. No.
Type of application
Type of Development
Percentage of Plots/F.A.R.
Plots used Minimum IT/ ITES/ESDM
Plots used Maximum Ancillary/ Commercial other Industry/ Residential
1.
IT unit/ITES/Unit
Plotted Development
85%
15%
IT unit/ITES
Building Construction
60%
40%
2.
ESDM Units
Plotted Development
85%
15%
3.
Developers of an IT Investment Area
Building Construction
85%
15%
Developers of an IT Investment Area
Building Construction
60%
40%]
Cul-De-Sacs.- Cul-de-sacs giving access to plots will be allowed provided that cul-de-sacs would be permissible only on straight roads and the turning space shall not be less than 121 square meters in area with no dimension being less than 11 meters.
Alley.- Alley may be provided where required. The width of the alley where provided shall not be less than 3 meters and no dead end alley shall be permitted unless provided with an adequate turn around facilities.
Intersection of roads.- (1) The layout for junctions of roads shall be in such a way that as far as possible all roads meet at right angle. Roads meeting at less than 30° should be avoided.
(2) For junctions of roads meeting at right angles or otherwise the rounding off or cut off or splay or similar treatment shall be done to the satisfaction of the Authority, depending upon the width of roads, the traffic generated, the sighting angle etc.
Rule 46-47
62
Building Line.- Subject to rule 56, building line shall be set back at least 3 meters from means of access.
Community Open Spaces and Amenities.- (1) The community open spaces shall be as follows :-
(a) Commercial Zones: In any layout or sub-division of land measuring 0.2 hectare or more and situated in commercial zones, the community open spaces shall be reserved for recreational purposes. Such space shall as far as possible, be provided in one place or may be planned out in clusters or pockets for the use of the community.
(b) Community Open Spaces in Residential Zones: In any Residential layout of plotted development or sub-division of land, Group Housing or Apartment Housing the community open spaces shall be reserved for recreational purposes. As far as possible these community open spaces shall be provided in one place or planned out in clusters or pockets, for the use of the community:
Provided that the minimum open spaces required may be notified by the State Government in the official Gazette and the same shall not be less than as mentioned in sub-rule (2) below.
(2) Minimum open area: The minimum community open spaces shall be,-
(i) 10 per cent. of the area of the layout; and
(ii) in case of economically weaker sections and low income group as prescribed in Appendix-J.
(3) Minimum average dimension of recreational space: The length of such area shall generally not exceed two and half times of the average width. However, depending on the configuration of the site, common open spaces of different shapes may be permitted by the Authority as long as the open spaces provided, serve the needs of the immediate community contiguous to the open spaces.
(4) Pavilion gymnasia: In such recreational spaces, a single storied structure up to 25 square meters of built up area, which may be used as pavilion or gymnasia, may be permitted. Such area may be excluded from floor area ratio calculations. Where the area of the open space exceeds 2000 sq. mtrs. in one place, the built up area of such gymnasia may extend upto 75 sq. mtrs..
(5) Independent means of access: Each recreational area and the structure on it shall have an independent means of access. Independent means of access may not be insisted if recreational space is approachable directly from every building in the layout. Further the building line shall be at least 3 meters away from the boundary of recreational open space.
Rule 48
63
Industrial Zones.- (1) Amenity open space in Industrial use: In every industrial zone, 5 per cent of the total area shall be reserved as open space. These open space may be used for parking, banking, canteens, welfare centers and such other common purposes as approved by the Authority.
(2) Open space in Industrial plots: In industrial plots measuring 1000 square meters or more, 10 percent of the total area shall be provided as an amenity open space. Such an amenity open space shall have a means of access and shall be so located that it would be conveniently utilised by the persons working in the industry.
(3) Development norms for Industrial plot shall be as follows :-
Norm for Industrial Plots
Sr. No.
Minimum Plot Area
Max. Ground Coverage in %
Minimum MOS in meters
Max. Floor Area Ratio (FAR)
Front
Side/Side
Rear
1
2
3
4
5
6
7
1.
Upto 0.045 Hect.
60
3.20
2.10/2.10
2.10
1.25
2.
More than 0.045 Hect. and upto 0.10 Hect.
60
4.50
3.00/3.00
3.00
1.25
3.
More than 0.10 Hect. and upto 0.20 Hect.
60
7.50
3.75/3.75
4.50
1.00
4.
More than 0.20 Hect. and upto 0.50 Hect.
60
9.00
4.50/4.50
4.50
1.00
5.
More than 0.50 Hect. and upto 0.75 Hect.
60
12.0
6.00/6.00
6.00
1.00
6.
More than 0.75 Hect. and upto 1.00 Hect.
60
15
7.50/7.50
7.50
1.00
7.
More than 1.00 Hect. and upto 1.25 Hect.
60
18
9.00/9.00
9.00
1.00
8.
More than 1.25 Hect. and upto 2.00 Hect.
60
21
10.50/10.50
10.50
1.00
9.
More than 2.00 Hect.
60
24
12.00/12.00
12.00
1.00
For Flatted Industries
1[10.
Minimum Plot Area 1500 Sq.m. (0.15 Hect.)
50
12.00
6.00/6.00
6.00
2.00]
1 Subs. by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025. Published in M.P. Rajpatra (Asadharan) S.N. 72 dated 06th March 2025 at pages 144-144(1).
Rule 48
64
53Size of plots and other norms.- (1) Residential :-
(i) Each plot shall have a minimum size and frontage corresponding to the type of development as given below:-
Type of Development
Plot size (Sq. meters)
Frontage (meters)
(1)
(2)
(3)
Detached building
above 225
above 12
Semi-detached building
125-225
8 to 12
Row type building
50-225
4.5 to 12
(ii) the norms of plot size for EWS/ LIG shall be as provided in Appendix-J.
(2) Industrial: The size of plot shall be such as approved by the Authority.
(3) Other land uses: The minimum size of plots for buildings for other uses like business, educational, mercantile, assembly, cinema/theatre, mangal karyalaya marriage garden, fuel filling stations etc., shall be as decided by the Authority subject to the clause (i) to (iv) below :-
(i) Assembly Halls/Theatres: The Minimum size of plot for assembly building/theaters used for public entertainment with fixed seats shall be on the basis of seating capacity of the building at the rate of 3 Square meters per Seat.
(ii) Cinema Halls with one screen: The norms shall be as under :-
1. Minimum area of the plot
- 2000 Square meter or 4 Sq. mt. per seat whichever is more
2. Ground coverage
- 33 per cent. of the total plot area. (on ground)
3. Floor Area Ratio
- 1.25
4. Minimum Open Spaces
- Front - Minimum 15 mtrs. Both sides - 6 Mts. Rear - 6 Mts.
5. Minimum width of road on which Cinema Plot should abut
18 mtrs.
Note : Commercial activities which is incidental to Cinema shall be permissible on 10 per cent. of the FAR.
(iii) Marriage Garden:
Development Norms for Marriage Garden shall be as below :-
Rule 53
71
S. No.
Components
Planning area having population 2.0 to 5.0 lacs
Planning area having population above 5.0 lacs
(1)
(2)
(3)
(4)
1.
Minimum Plot / Land area
4000 Square meters
10000 Square meters
2.
Minimum Road width in front
12 meters
18 meters
3.
Minimum frontage
25 meters
40 meters
4.
Maximum FAR
0.10
0.10
5.
Maximum Ground Coverage
10 per cent.
10 per cent.
6.
Minimum Parking Area in the front
30 per cent. of plot / land area
40 per cent. of plot / land area
7.
M.O.S. : Front
6.0 meters after parking space
6.0 meters after parking space
8.
Permissibility in land use
Residential / Commercial / Agriculture / PSP
Residential / Commercial / Agriculture
(iv) Fuel filling Station :
(a) National highways : For the site of Fuel filling station situated on the National Highways, norms as decided by the Ministry of Road Transport and Highways and or Ministry of Petroleum, Government of India shall be applicable.
1[(b) Roads Other than National Highways : Norms for the site of the Fuel filling Station situated on the roads other than National Highways shall be as follows :-
S. No.
Population
Minimum Plot Size (in meters)
Frontage of the plot (in meters)
Minimum road width in front of the plot (in meters)
Permissibility in land used of approved development land
Only Fuel Filling Station (FFS)
Fuel Filling Station with Service Facilities (FFSS)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
1.
Less than 0.5 lac
20×20
35×35
20(FFS)35(FFSS)
15
Residential, Mixed, Commercial, Industrial,
Subs. by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025. Published in M.P. Rajpatra (Asadharan) S.N. 73 dated 06th March 2025 at pages 145-146(2).
Rule 53
72
2.
0.5 lac to 5 lac
20×20
35×35
20(FFS)35(FFSS)
18
Public and semi-Public, Transportation, Agriculture and Recreational. Agriculture and Recreational
3.
Above 5 lac
20×20
35×35
20(FFS)35(FFSS)
24
Note:-
(1) No fuel filling station shall be permitted within the minimum buffer area from the highest water level of the water body as specified in rule 50(b).
(2) In rural areas, the minimum size of the plot for Kisan Seva Kendra and fuel filling station shall be 20 X 20 meters and the width of the approach shall be minimum 15.00 meters.
(3) Workshop shall not be permitted in the FFS mentioned in column (3).
(4) For plot mentioned in column (4) maximum built up areas shall not exceed 15% of the total plot area which may include workshop and other services and facilities such as snacks stall, ATM, etc.
(5) In case of plot size more than that mentioned in column (4), in addition to fuel filling station with services and amenities (FFSS), multi-level parking. Electric vehicle Charging station and/or battery swapping station may also be accepted. For this, it will be necessary to follow the norms issued by Administrative Department or Regulatory Authority
For Standalone PCS:
(6) The ratio of provision of charging points (FC/SC) with respect to total parking capacity will be considered for only 20% (i.e. 20% of total parking capacity will be considered EVs & ratio will be applied on them)
(7) Land a/location is preferably to be contiguous/in close proximity to commercial land of the Mid-way Restaurant.
Rule 54-55
76
(8) "General Conditions of Siting" of Standalone PCS shall follow clause 4.1-4.4 of IRC: 12 (latest revision) except for the distance between stations which shall be as per the Guidelines issued by MoP, dated Dec, 2018.
Abbreviations:
BS
Battery Swap
CCE
Climate Control Equipment
CCS
Combined Charging System
CHAdeMo
A DC fast charging standard
CNG
Compressed Natural Gas
COCO
Company Owned Company Operated
EV
Electric Vehicle
FC
Fast Charger/ Fast Charging (DC and a few AC ones)
FCB CS
Fluid Cooled battery Charging Station
LCC
Liquid Cooled Cables
MoP
Ministry of Power
PCS
Public Charging Stations
PESO
Petroleum & Explosives Safety Organization
SC
Slow Charger / Slow Charging (AC)
SP
Service Provider]
(6) Ladies and gents toilets, drinking water, equipments for fire fighting shall be necessarily provided in all fuel filling stations.]
1[(C) The development norms for Electric Vehicle (EV) Charging and service centre :
(1): Development norms for Electric Vehicle (EV) Charging and service centre shall be as per table below:-
1 Inserted by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025.
Published in M.P. Rajpatra (Asadharan) S.N. 74 dated 06th March 2025 at pages 147-148(9).
Rule 53
S.N.
Categor y
Permitted in
Land Requirement
Other Control
Type of facility
Area requirement
1
2
3
4
5
6
1
Electric Vehicle (EV) Chargi ng and service centre
Permitted in: 1. Central District 2. Sub district central 3. District Centres 4. Community Centres (Only Filling Station) 5. Residential & industrial use Zone In urban Areas. 6. Along National & Highways State 7. Villages identified as growth centres. 8. Freight Complex 9. Proposed major roads. 10.Police/Secu rity forces services (for captive use only)
Public Charging Station (PCS) (Minimum requirement as per MoP Guidelines)
Min 13.5m X 5.5 m
1. Shall not be located on road having Right of way less than 30 m. 2. Special cases in old city areas may. be considered based on the approval by statutory authorities. 3. Shall be approved by the explosives/fir e department. 4. Charging Station and all equipment layout with respect nearest dispensing unit (DU)/fuel tank to be as per PESO rules. to 5. Equipped with Climate Control Equipment (CCE) and Liquid Cooled Cables (LCC) as required in addition to requirements of Public Charging Station (PCs). 6. Optional addition to PCs by the Service Provider (SP).
Fluid Cooled battery Charging Station (FCB CS) 1 Combined Charging System (CCS) 1 CHAdeMO (ADC fast charging standard)
Min 15m X 7 m
Battery swapping station (optional)
Earmarking area for "Battery fitting"
Rule 53
74
2
Compr e ssed Natural Gas (CNG) filling centre
1. Permitted in All use(except zones in Regional Parks Developed District Parks) 2. Along National and Highways 3. Villages identified as growth centres 4. Freight Complex 5. Proposed major roads
CNG mother station (Including building component -controlroom/office/dispensingandroom/store, pantry and WC.)
1080 sqm (36m x 30m
1. Shall not be located on road having Right of Way less 30m. than 2. Shall be approved by the explosive/firedepartment
(2): Development norms for Standalone Public Charging Stations (PCS) shall be as per table below:-
S. No
Category
Population served per unit
Land Requirement
Other Control
Type of facility
Area requirement
1
2
3
4
5
6
A
Public Charging Stations
Every 25 Kms, both Sides along the highways/roads
Public Charging Station (PCS) with charger ratio (minimum requirements of PCS, as per MoP) 1 Fast Charger (FC) fol every iC EVs1SiowCharger (SC) for every 3 EVs
Additional area as per total parking capacity at theRestaurants/Eateries.
Equipped with Climate Control Equipment (CCE) and Liquid Cooled Cables (LCC), as may be required fast charging
Rule 53
75
B
Fast Charging facility / Fluid Cooled battery Charging Station (FCB CS) (for Long, Distance & Heavy Duty EVs)
Every 100 Kms, both Sides along the highways/ roads
At least 2 chargers 1 CCC type1CHAdeM O type (min100KWeach)
Min.15m x 7m
May be coupled with PCS a item A above with CCE and LCC.
C
Battery Swapping Station
Optional provisions as per MoP Guidelines.
Standalone
Min 5.5m x 2.75m
May be coupled with PCS at item A or FCB CS at item B above
Provided along with FBC charging Stations
Notes:
(1) Super Kerosene Oil/Light Diesel Oil storage for industrial uses shall be given separately.
(2) To be organized by a service provider for connection and metering, available 24x7for all users.
(3) Provision of FCB CS & BS shall not be mandatory, and will be at the discretion of the service provider.
(4) Size recommended for FCB CS is subject to variance as per technical specifications of the SP.
(5) Fuel filling stations (including COCO outlets) shall conform to specifications and safety norms as per the amendment in Petroleum Rules or, PESO Act and obtain clearances as maybe necessary from the 'Competent Authority', for adding PCS to Retail outlets/ Fuel filling stations.