29. Basement. –
The condition of basement shall be as follows :–
(a) no portion of the basement shall be allowed to encroach upon the mandatory open spaces;
(b) the portion of the basement beyond the building profile shall flush with the ground level if the same is not taken in the ground coverage. The structure of such basement should be so designed that it should be capable of taking the load of heavy vehicles like fire engines etc.;
(c) every basement shall be in every part at least 2.5 meters in height from the floor to underside of the roof slab or beam or ceiling and with maximum height not more than 4.75 meter;
(d) adequate ventilation shall be provided for the basement. The standard of ventilation shall be of acceptable limit. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans [one exhaust fan (300 mm dia, 1400 rpm, heavy duty) for 50 square meters basement area], air conditioning system, etc.;
(e) the minimum height of the ceiling of any basement shall be 0.9 meter and maximum of 1.2 meter above the average road level on the front side of the building, if not flushed with the ground level;
(f ) adequate arrangement shall be made such that surface water does not enter the basement;
(g) the walls and floors of the basement shall be watertight and be so designed that the effect of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given;
(h) all the staircases from the basement shall be segregated on the ground floor level.
(i) In case the Development Authority allows the partitions in the basements, no compartment shall be less than 50.0 square meters in area and each compartment shall have ventilation standards as laid down in subclause (d) above separately and independently. The basement partition shall however, confirm to the norms laid down by West Bengal Fire and Emergency Services.
(j) The other provisions of prevailing National Building Code shall be used for guidance.
30. Miscellaneous.–
(1) The construction of advertising signs and outdoor display structures shall be in accordance with the provisions of Signs and Outdoor Display Structure of the provisions of the National Building Code of India, and orders issued by the Development Authority from to time.
(2) Every building shall display, in a prominent place on the front side, the premises number and the road or street name or number as assigned to it by the planning authority, so as to be conveniently visible from the road or street as per the specifications laid down by the Development Authority.
(3) All construction materials shall be stored within the plot. As soon as the construction of any building is completed, all rubbish, refuse or debris of any description shall be removed to the satisfaction of the Development Authority by the Owner from the site or sites on which erection of building have taken place or from any adjoining land which may have been used for deposition of materials or debris.
(4) All buildings in plot sizes of 1 acres or more, shall have close circuit television facilities along with security alarm for safety and security reasons. Such installations whether provided will be checked before issuance of occupancy/partial occupancy certificate.
31. Boundary wall or compound wall and compound gate.–
(1) Except with the special permission of the Development Authority, the maximum height of the compound wall shall not be 1.5 meter above the centre line of the Means of access. Compound wall up to 2.4 meter height may be permitted if the top 0.9 meter is of open type constructions.
Provided that the provisions of this sub-rule are not applicable to boundary walls of jails, electric sub-stations, transformer stations, institutional buildings like sanatorium, hospitals, industrial buildings like workshops, factories, storage buildings, educational buildings like schools, colleges,
including hostels, and other uses of public-utility undertakings. Provided further that the height of the compound wall of the buildings mentioned hereinabove provision may be permitted up to 2.4 meters.
(2) Provided further that the height of compound walls for jails, electric sub-stations, transformer stations, sanatorium, hospitals, workshops, factories, storage buildings, army institutions etc. shall be as per their own norms or subject to approval of the Development Authority;
32. Master plan of plots –
(a) In case of plots above 1 hectare in area Master Plan for the entire plot shall be submitted for approval by the Planning Authority or Development Authority. Building plans for the entire plot or a part of it will be submitted for sanction on approval of the Master plan.
(b) Master plan shall contain:
(i) Layout of the plot showing –
(a) building outline (b) basement boundary (c) internal roads and their connectivity with means of access (d) marginal open spaces (e) green open spaces
(ii) water supply, sewerage and drainage connection points to the plot.
(iii) written statement indicating height of each building, total floor area, FAR and ground coverage.
33. Special Provisions for Rehabilitation and Resettlement Schemes.
(1) The owner of Rehabilitation and Resettlement Plots shall apply in plain paper to the sanctioning authority along with the Architectural drawing signed by him, as per the rules set under the guidelines for the Rehabilitation and Resettlement Plots.
(2) Notwithstanding anything contained in any other provisions of these rules, the concerned technical person shall have at least a Diploma in Architecture for Rehabilitation and Resettlement Plots;
(3) A sum of Rs. 200.00 per floor shall be levied from the owner of the Rehabilitation and Resettlement Plots as building sanction fees.
(4) Maximum size of R.R. Plot is 67 square meters.
(5) Minimum width of means of access to the Rehabilitation and Resettlement Plots shall not be less than 3.5 meters.
(6) Plinth height shall not be less than 450 mm.
(7) Open spaces for the building :–
(a) minimum front open space is 0.8 meter;
(b) minimum rear open space is 1.2 meter;
(c) minimum side open spaces are –
(i) side 1 - 0.8 meter,
(ii) side 2 - 1.2 meter
(8) Maximum height of the building is 7 meters.
(9) Stair cover or mumpty room shall not exceed 2.6 meters in height.
(10) Support of roof tank shall not exceed 1 meter in height.
(11) Parapet shall not exceed 1meter in height.