FORM I Form for Application to Erect, Re-Erect or to make material Alteration in any Place in a Building
To,
The Meghalaya Urban Development Authority
Sir/Madam,
I hereby give notice on behalf of Shri. (owner) that the owner intends to erect/demolish or make alteration the building situated at and in accordance with the building Bye-law No and I forward herewith, the following plans and specification duly signed by me and by the owner
Site plan, Building Plan, Section , Elevation
Ownership Title (lease/Conveyance/Sale Deed, etc)
Affidavit cum undertaking as per Form I(a)
Statement of Proposal and Certificate as per Form I(b) and (c)
Certificate of Undertaking as per Form I(d)
Structural Design Basis Report
Other document, as required Service Plan, Parking and circulation plan, Landscape Plan
(i) The building plan has been prepared strictly as per the approved building Byelaws. The construction shall be carried out in accordance with the building plan and I shall be completely accountable for any lapse on my part up to within 6 months after obtaining completion certificate of the building.
(ii) I am aware that in the event of building being constructed in violation of the sanctioned building plan approval, the Authority shall have the right to take fiction against me as it may deem fit and/or including referring the matter to Council of Architecture for taking disciplinary action against me.
Signature of the Owners
(Signature of Registered
Name of owner(s) ......
Architect/Engineer/Supervisor)
Address of the owner(s)
Registration No. of the
Architect/Engineer/Supervisor
Address of the Architect/Engineer/ Supervisor
Encl : A stated above
Dated .
FORM I(A)
Appendix DModel Proforma for Technical Audit Report
Design
COMMENTS
1.1. Design/Drawings available?
Y/N
Design category Type design? Specific design?
Y/N Design to be collected to refer to Design Consultant/H.O.
Drawings prepared / checked by competent Authority?
Y/N
Design drawings / details Structural detailed included Earthquake/cyclone resistant features included?
Y/NY/N
Design verified/vetted by Dept./Govt. approved agency/competent authority?
Y/N
Design changes approved by Dept./Govt. approved agency/competent authority?
Y/N
Foundation
2.1. Foundation used Existing/New
2.2.1 If existing foundation used
2.2.1. Depth of foundation below ground <50cm/50-70/>70cm
2.2.2. Type of masonry Stone/brick/PCC blocks
2.2.3. Thickness of masonry (above ground): 23cm/35/>35
2.2.4. Mortar used Cement-sand/Lime/Mud
2.2.5. Mix of cement mortar 1:4/1:6/Leaner
2.2.6. Height upto plinth cm
2.2.7.If stone mason
2.2.7.1 Through stones Yes/No, if Yes Adequate/inadequate
2.2.7.2 Corner stones Yes/No, if Yes Adequate/Inadequate
2.3. If new foundation used
2.3.1. Depth of foundation below ground <50/50-70/>70cm
2.3.2. Type of masonry blocks stone/bricks/PCC
2.3.3. Thickness of masonry above plinth 23cm/35/>35cm
2.3.4. Mortar used Cement-sand/lime/mud
2.3.5. Mix cement mortar (1:4) Yes/No
2.3.6. Height up to plinth <60/>60cm
2.3.7.1 Through Stones Yes/No, if yes Adequate/Inadequate
2.3.7.2 Corner Stones Yes/No, if yes Adequate/Inadequate
2.4. Vertical reinforcement in foundation : Yes/No