9.2.1 Size and Dimension of Habitable Rooms
Size and dimension of habitable rooms, shall be as per requirement and convenience of the owner.
9.2.2 Height of Habitable Rooms
The minimum and maximum height of a habitable room shall be given in Table No.9A hereunder:
| Table No. 9 A | |||
| No. | Occupancy | Minimum Height (m) | Maximum Height (m) |
| (1) | (2) | (3) | (4) |
| 1 | Flat Roof - | ||
| a) Any habitable room | 2.75 | 4.5 | |
| a1) Habitable room in EWS / LIG Housing. | 2.75 | 4.2 | |
| b) Air-conditioned habitable room | 2.4 | 4.5 | |
| c) Assembly Halls, Residential Hotels of 3 star category and above, Institutional, Educational, Industrial, Hazardous or storage occupancies, Departmental Stores, Malls, IT Buildings, Office Buildings, Exhibition Centre, Convention Hall, Theatre, Film Studio, Entrance Halls and Lobbies to these buildings. | 3.0(2.40 m. in case of Air conditioned room) | 6.00 or higher according to the requirement of occupancy. | |
| d) Shops | 3.00 | 4.5 | |
| 2 | Pitched roof- | |||
| a) Any habitable room | 2.75 (average with 2.0 m. at the lowest point) | 4.5 (average with 3.2 m. at the lowest point) | ||
| b) Habitable room in EWS / LIG Housing. | 2.6 (average with 2.0 m. at the lowest point) | 4.2 (average with 3.2 m. at the lowest point) | ||
| Provided that the minimum head-way under any beam shall be 2.4 m.Provided further that height more than that specified above, if required for particular occupancy, shall not be counted towards calculation of FSI. | ||||
| 9.3 | KITCHEN | |||
| 9.3.1 | Size of KitchenThe size of kitchen or a cooking alcove serving as cooking space shall be as per requirement and convenience of the owner. | |||
| 9.3.2 | Height of KitchenThe height of a kitchen measured from the surface of the floor, to the lowest point in the ceiling (bottom of slab) shall not be less than 2.75 m. except for the portion to accommodate floor trap of the upper floor. | |||
| 9.4 | BATH ROOMS, WATER CLOSETS, COMBINED BATH ROOM AND WATER CLOSET | |||
| 9.4.1 | Size of bath room and water closetMinimum size shall be as underi) Independent Bath room 1.00 m. x 1.20 m.ii) Independent Water closet 0.9 m. x 0.9 m.iii) Combined bath room and water closet 1.50 Sq.m. with minimum width or 1.00m. | |||
| 9.4.2 | Height of bath room and water closetThe height of a bathroom or water closet measured from the surface of the floor to the lowest point in the ceiling (bottom of slab) shall be not less than 2.1m. | |||
| 9.4.3 | Other requirements of bath room and water closetEvery bathroom or water-closet shall -i) be so situated that it derives ventilation from ventilation shaft or external air,ii) have a window or ventilator, opening to a shaft or open space, of area not less than 0.3sq.m. with side not less than 0.3m.iii) all the sewerage outlets shall be connected to the sewerage system. Where no such systems exist, a septic tank shall be provided within the plot conforming to the requirements of Regulation No.9.25 | |||