2.1 For the purpose of this Section, the following definitions shall apply.
2.1.1 Access Panel — Removable panel mounted in a frame, normally secured with screws and mounted in a wall or ceiling, to provide access to concealed appurtenances or items which may require maintenance.
2.1.2 Air Gap — The distance between the lowest point of a water inlet or feed pipe to an appliance and the spill-over level (or the overflowing level) of the appliance.
2.1.3 Air Valve — A valve that releases air from a pipeline automatically without loss of water, or introduce air into a line automatically if the internal pressure becomes less than that of the atmosphere.
2.1.4 Authority Having Jurisdiction — The Authority which has been created by a statute and which for the purpose of administering the Code/Part may authorize a committee or an official to act on its behalf; hereinafter called the ‘Authority’.
2.1.5 Available Head — The head of water available at the point of consideration due to mains’ pressure or overhead tank or any other source of pressure.
2.1.6 Back Siphonage — The flowing back of used, contaminated, or polluted water from a plumbing fixture or vessel into a water supply due to a reduced pressure in such pipe (see Backflow).
2.1.7 Back Up — A condition where the wastewater may flow back into another fixture or compartment but not back into the potable water system.
2.1.15Branch
a) Special form of sewer pipe used for making connections to a sewer or water main. The various types are called ‘T’, ‘Y’, ‘T–Y’, double Y and V branches, according to their respective shapes.
b) Any part of a piping system other than a main or stack.
2.1.16 Branch Soil Pipe (BSP) — A pipe connecting one or more soil appliances to the main soil pipe.
2.1.17 Branch Soil Waste Pipe (BSWP) — A pipe connecting one or more soil and/or waste appliances to the main soil waste pipe (one pipe system).
2.1.18 Branch Ventilating Pipe (BVP) — A pipe, one end of which is connected to the system adjacent to the trap of an appliance and the other to a main ventilating pipe or a drain-ventilating pipe. It is fitted to prevent loss of water seal from a trap owing to partial vacuum, back-pressure, or surging caused by air movement within the pipe system. It also provides ventilation for the branch waste pipe.
2.1.19 Branch Waste Pipe (BWP) — A pipe connecting one or more waste appliances to the main waste pipe.
2.1.20 Building Drain, Combined — A building drain which conveys both sewage and storm water or other drainage.
2.1.21 Building Drain, Sanitary — A building drain which conveys sewage and sullage only.
2.1.22 Building Drain, Storm — A building drain which conveys storm water or other drainage but no sewage.
2.1.23 Building Sewer — That part of the horizontal piping of a drainage system which extends from the end of the building drain and which receives the discharge of the building drain and conveys it to a public sewer, private sewer, individual sewagedisposal system or approved point of disposal.
2.1.24 Building Sub-Drain — That portion of a drainage system which cannot drain by gravity in the building sewer.
2.1.25 Building Trap — A device, fitting or assembly of fittings installed in the building drain to prevent
circulation of air between the drainage of the building and the building sewer. It is usually installed as running trap.
2.1.8Backflow
a) The flow of water or other liquids, mixtures or substances into the distributing pipes of a system of supply of potable water from any source or sources other than its intended source.
b) The flow of a liquid in a direction reverse of that intended.
2.1.9 Backflow Prevention Device — Any approved measure or fitting or combination of fittings specifically designed to prevent backflow or backsiphonage in a water service.
2.1.10 Barrel — This portion of a pipe in which the diameter and wall thickness remain uniform throughout.
2.1.11 Base — The lowest portion or lowest point of a stack of vertical pipe.
2.1.12 Battery of Fixtures — Any group of two or more similar adjacent fixtures which discharge into a common horizontal waste or soil pipe.
2.1.13 Bedding — The material on which the pipe is laid and which provides support for the pipe. Bedding can be concrete, granular material or the prepared trench bottom.
2.1.14 Benching — Slopping surfaces constructed on
either side of channels at the base of a manhole or inspection chamber for the purpose of confining the flow of sewage, avoiding the accumulation of deposits and providing a safe working platform.
1Scope
1.1 This Section covers the basic requirements of water supply for residential, business and other types of buildings, including traffic terminal stations. This Section also deals with general requirements of plumbing connected to public water supply and design of water supply systems.
1.1.1 This Section does not take into consideration the requirements of water supply for industrial plants and processes, which have to be provided for separately. It also does not provide the requirements of water supply for other purposes, such as fire fighting, and street cleaning.
1.2 This Section also covers the design, layout, construction and maintenance of drains for foul water, surface water and subsoil water and sewage; together with all ancillary works, such as connections, manholes and inspection chambers used within the building and from building to the connection to a public sewer, private sewer, individual sewage-disposal system, cesspool, soakaway or to other approved point of disposal/ treatment work.
NOTE — A sanitary drainage system consists of a building sewer, a building drain, a soil and/or waste stack, horizontal branches or fixture drain, and vents. The sanitary drainage of a large building may have a number of primary and secondary branches, and several soil and/or waste stacks, each of them in turn may have a number of horizontal branches.
2.1.26Cesspool
a) An underground chamber for the reception and storage of foul water, the contents of which are periodically removed for disposal.
b) A box-shaped receiver constructed in a roof or gutter for collecting rainwater which then passes into a rainwater pipe connected thereto.
2.1.27 Chair — A bed of concrete or other suitable material on the trench floor to provide a support for the pipes at intervals.
2.1.28 Channel — The open waterway through which sewage, storm water or other liquid wastes flow at the invert of a manhole or an inspection chamber.
2.1.29 Chute — A vertical pipe system passing from floor to floor provided with ventilation and inlet openings for receiving refuse from successive floors and ending at the ground floor on the top of the collecting chambers.
2.1.30 Cistern — A fixed container for water in which water is at atmospheric pressure. The water is usually supplied through a float operated valve.
2.1.31 Cleaning Eye — An access opening in a pipe or pipe fitting arranged to facilitate the cleaning of obstructions and fitted with removable cover.
2.1.32 Clear Waste Water — Cooling water and condensate drainage from refrigeration and air conditioning equipment, cooled condensate from steam heating systems, cooled boiler blow-down water, waste water drainage from equipment rooms and other areas where water is used without an appreciable addition of oil, gasoline, solvent, acid, etc, and treated effluent in which impurities have been reduced below a minimum concentration considered harmful.
2.1.33 Collection Chamber — A compartment situated at the lower end of the chute for collecting and housing the refuse during the period between two successive cleanings.
2.1.34 Communication Pipe — That part of a service pipe which vests in the water undertakes. It starts at the water main and terminate at a point which differs according to the circumstances of the case.
2.1.35 Connection — The junction of a foul water drain, surface water drain or sewer from building or
NOTE — The illustration is not intended to indicate recommended positions of underground storage tank (where provided), pipes, etc and this will depend on local situations.
FIG. 1 TYPICAL SKETCH FOR IDENTIFICATION OF DIFFERENT TYPES OF WATER SUPPLY PIPES
building with public sewer treatment works, public sewer, private sewer, individual sewage-disposal system, cess pool, soakaway or to other approved point of disposal/treatment work.
2.1.36 Consumer — Any person who uses or is supplied water or on whose application such water is supplied by the Authority.
2.1.37 Consumer’s Pipe — The portion of service pipe
used for supply of water and which is not the property of the Authority (see Fig. 1).
2.1.91Plumbing
a) The pipes, fixtures and other apparatus inside a building for bringing in the water supply and removing the liquid and water borne wastes.
b) The installation of the foregoing pipes, fixtures and other apparatus.
2.1.92 Plumbing System — The plumbing system shall include the water supply and distribution pipes; plumbing fittings and traps; soil, waste, vent pipes and anti-siphonage pipes; building drains and building sewers including their respective connections, devices
FIG. 3 DIAGRAM OF ONE-PIPE SYSTEM
FIG. 4 DIAGRAM OF TWO-PIPE SYSTEM
and appurtenances within the property lines of the premises; and water-treating or water-using equipment.
2.1.93 Potable Water — Water which is satisfactory for drinking, culinary and domestic purposes and meets the requirements of the Authority.
2.1.94 Premises — Premises shall include passages, buildings and lands of any tenure, whether open or enclosed, whether built on or not, and whether public or private in respect of which a water rate or charge is payable to the Authority or for which an application is made for supply of water.
2.1.95 Puff Ventilation — The ventilation provided for waste traps in two-pipe system, in order to preserve the water seal.
2.1.96 Residual Head — The head available at any particular point in the distribution system.
2.1.97 Saddle — A purpose made fitting, so shaped as to fit over a hole cut in a sewer or drain used to form connections.
2.1.98 Sanitary Appliances — The appliances for the collection and discharge of soil or waste matter.
2.1.99 Service Laterine — A laterine from which the excreta are removed by manual agency and not by water carriage.
2.1.100 Service Pipe — Pipe that runs between the distribution main in the street and the riser in case of a multi-storeyed building or the water meter in the case of an individual house and is subject to water pressure from such main.
2.1.101 Sewer — A pipe or conduit, generally closed, but normally not flowing full for carrying sewage and/ or other waste liquids.
2.1.38Cover
a) A removable plate for permitting access to a pipe, fitting, vessel or appliance.
b) The vertical distance between the top of the barrel of a buried pipe or other construction and the surface of the ground.
2.1.39 Cross-Connection — A connection between two normally independent pipelines which permits flow from either pipeline into the other.
2.1.40 Crown of Trap — The topmost point of the inside of a trap outlet.
2.1.41 Deep Manhole — A manhole of such depth that an access shaft is required in addition to the working chamber.
2.1.42 Depth of Manhole — The vertical distance from the top of the manhole cover to the outgoing invert of the main drain channel.
2.1.43 Diameter — The nominal internal diameter of pipes and fittings.
2.1.44 Direct Tap — A tap which is connected to a supply pipe and is subject to pressure from the water main.
2.1.45 Downtake Tap — A tap connected to a system of piping not subject to water pressure from the water main.
2.1.46 Drain — A conduit, channel or pipe for the carriage of storm water, sewage, waste water or other water-borne wastes in a building drainage system.
2.1.47 Drain Ventilating Pipe (DVP) — A pipe installed to provide flow of air to or from a drain to prevent undue concentration of foul air in the drain. The main soil pipe or main waste pipe may serve as drain ventilating pipe wherever their upper portions, which do not receive discharges, are extended to the roof level and let open to air.
2.1.48 Drainage — The removal of any liquid by a system constructed for the purpose.
2.1.49 Drainage Work — The design and construction of a system of drainage.
2.1.50 Drop Connection — A length of conduit installed vertically immediately before its connection to a sewer or to another drain.
2.1.51 Drop Manhole — A manhole installed in a sewer where the elevation of the incoming sewer considerably exceeds that of the outgoing sewer; a vertical waterway outside the manhole is provided to divert the waste from the upper to the lower level so that it does not fall freely into the manhole except at peak rate of flow.
2.1.52 Effective Opening — The minimum cross-sectional area at the point of water supply, measured or expressed in terms of:
a) the diameter of a circle; and
b) the diameter of a circle of equivalent cross-sectional area, if the opening is not circular.
2.1.53 Feed Cistern — A storage vessel used for supplying cold water to a hot water apparatus, cylinder or tanks.
3General
3.1 Basic Principles
3.1.1 Potable Water
All premises intended for human habitation, occupancy, or use shall be provided with supply of potable water. This water supply shall not be connected with unsafe water resources, nor shall it be subject to the hazards of backflow.
3.1.2 Water Provision
Plumbing fixtures, devices and appurtenances shall be provided with water in sufficient volume and at pressures adequate to enable them to function properly and without undue noise under normal conditions of use.
There should be at least a residual head of 0.018 N/mm2 at the consumer’s tap.
NOTE — The residual head shall be taken at the highest/farthest outlets in the building.
3.1.3 Water Conservation
Plumbing system shall be designed, installed and adjusted to use the optimum quantity of water consistent with proper performance and cleaning.
3.1.4 Safety Devices
Plumbing system shall be designed and installed with safety devices to safeguard against dangers from contamination, explosion, overheating, etc.
3.1.5 Plumbing Fixtures
It is recommended that each family dwelling unit should have at least one water closet, one lavatory, one kitchen wash place or a sink, and one bathing wash place or shower to meet the basic requirements of sanitation and personal hygiene.
3.1.6 Drainage System
The drainage system shall be designed, installed and maintained to guard against fouling, deposit of solids
and clogging and with adequate cleanouts so arranged that the pipes may be readily cleaned.
3.1.7 Materials and Workmanship
The plumbing system shall have durable material, free from defective workmanship and so designed and installed as to give satisfactory service for its reasonable expected life.
3.1.8 Fixture Traps and Vent Pipes
Each fixture directly connected to the drainage system shall be equipped with a liquid seal trap. Trap seals shall be maintained to prevent sewer gas, other potentially dangerous or noxious fumes, or vemin from entering the building. Further, the drainage system shall be designed to provide an adequate circulation of air in all pipes with no danger of siphonage, aspiration, or forcing of trap seals under conditions of ordinary use by providing vent pipes throughout the system.
2.1.102 Slop Hopper (Slop Sink) — A hopper shaped sink, with a flushing run and outlet similar to those of a WC pan, for the reception and discharge of human excreta.
2.1.103 Soakaway — A pit, dug into permeable ground lined to form a covered perforated chamber or filled with hard-core, to which liquid is led, and from which it may soak away into the ground.
2.1.104 Soffit (Crown) — The highest point of the internal surface of a sewer or culvert at any cross-section.
2.1.105 Soil Appliances — A sanitary appliance for the collection and discharge of excretory matter.
2.1.106 Soil Pipe — A pipe that conveys the discharge of water closets or fixtures having similar functions, with or without the discharges from other fixtures.
2.1.107 Soil Waste — The discharge from water closets, urinals, slop hooper, stable yard or cowshed gullies and similar appliances.
2.1.108 Stop-Cock — A cock fitted in a pipe line for controlling the flow of water.
2.1.109 Stop Tap — Stop tap includes stop-cock, stop valve or any other device for stopping the flow of water in a line or system of pipes at will.
2.1.110 Storage Tank — A container used for storage of water which is connected to the water main or tubewell by means of supply pipe.
2.1.111 Sub-Soil Water — Water occurring naturally in the sub-soil.
2.1.112 Sub-Soil Water Drain
a) A drain intended to collect and carry away sub-soil water.
b) A drain intended to disperse into the sub-soil from a septic tank.
2.1.113 Sub-Zero Temperature Regions — Regions where temperatures fall below 0°C and freezing conditions occur.
2.1.114 Sullage — See 2.1.129.
2.1.115 Supply Pipe — So much of any service pipe as is not a communication pipe.
2.1.116 Supports — Hangers and anchors or devices for supporting and securing pipe and fittings to walls, ceilings, floors or structural members.
2.1.117 Surface Water — Natural water from the ground surface, paved areas and roofs.
2.1.118 Surface Water Drain — A drain conveying surface water including storm water.
2.1.119 Systems of Drainage
a) Combined system — A system in which foul water (sewage) and surface water are conveyed by the same sewers and drains.
b) Separate system — A system in which foul water (sewage) and surface water are conveyed by the separate sewers and drains.
c) Partially separate system — A modification of the separate system in which part of the surface water is conveyed by the foul (sanitary) sewers and drains.
2.1.120 Trade Effluent — Any liquid either with or without particles of matter in suspension which is wholly or in part produced in the course of any trade or industry, at trade premise. It includes farm wastes but does not include domestic sewage.
2.1.121 Trap — A fittings or device so designed and constructed as to provide, when properly vented, a liquid seal which will prevent the back passage of air without materially affecting the flow of sewage or waste water through it.
2.1.122 Vertical Pipe — Any pipe or fitting which is installed in a vertical position or which makes an angle or not more than 45° with the vertical.
2.1.123 Vent Stack/Vent Pipe — A vertical vent pipe installed primarily for the purpose of proving circulation of air to and from any part of the drainage system. It also protects trap seals from excessive pressure fluctuation.
2.1.124 Vent System — A pipe or pipes installed to provide a flow of air to or from a drainage system or to provide a circulation of air with in such system to protect traps seals from siphonage and back-pressure.
2.1.125 Warning Pipe — An overflow pipe so fixed that its outlet, whether inside or outside a building, is in a conspicuous position where the discharge of any water therefrom can be readily seen.
2.1.126 Wash-Out Valve — A device located at the bottom of the tank for the purpose of draining a tank for cleaning, maintenance, etc.
2.1.127 Waste Appliance — A sanitary appliance for the collection and discharge of water after use for ablutionary, culinary and other domestic purpose.
2.1.128 Waste Pipe — In plumbing, any pipe that receives the discharge of any fixtures, except waterclosets or similar fixtures and conveys the same to the house drain or soil or waste stack. When such pipe does not connect directly with a house drain or soil stack, it is called an indirect waste pipe.
2.1.129 Waste-Water (Sullage) — The discharge from wash basins, sinks and similar appliances, which does not contain human or animal excreta.
2.1.130 Water Main (Street Main) — A pipe laid by the water undertakers for the purpose of giving a general supply of water as distinct from a supply to individual consumers and includes any apparatus used in connection with such a pipe.
2.1.131 Water Outlet — A water outlet, as used in connection with the water distributing system, is the discharge opening for the water (a) to a fitting; (b) to atmospheric pressure (except into an open tank which is part of the water supply system); and (c) to any wateroperated device or equipment requiring water to operate.
2.1.132 Water Seal — The water in a trap, which acts as a barrier to the passage of air through the trap.
2.1.133 Water Supply System — Water supply system of a building or premises consists of the water service pipe, the water distribution pipes, and the necessary connecting pipes, fittings, control valves, and all appurtenances in or adjacent to the building or premises.
2.1.134 Waterworks — Waterworks for public water supply include a lake, river, spring, well, pump with or without motor and accessories, reservoir, cistern, tank, duct whether covered or open, sluice, water main, pipe, culvert, engine and any machinery, land, building or a thing used for storage, treatment and supply of water.
2.1.54 Fittings — Fittings shall mean coupling, flange, branch, bend, tees, elbows, unions, waste with plug, P or S trap with vent, stop ferrule, stop tap, bib tap, pillar tap, globe tap, ball valve, cistern storage tank, baths, water-closets, boiler, geyser, pumping set with motor and accessories, meter, hydrant, valve and any other article used in connection with water supply, drainage and sanitation.
2.1.55 Fixture Unit — A quantity in terms of which the load producing effects on the plumbing system of different kinds of plumbing fixtures is expressed on some arbitrarily chosen scale.
2.1.56 Fixture Unit Drainage — A measure of probable discharge into the drainage system by various types of plumbing fixtures. The drainage fixture unit value for a particular fixture depends on its volume rate of drainage discharge, on the time duration of a single drainage operation and on the average time between successive operations.
2.1.57 Float Operated Valve — Ball valves or ball taps and equilibrium valves operated by means of a float.
2.1.58 Flushing Cistern — A cistern provided with a device for rapidly discharging the contained water and used in connection with a sanitary appliance for the purpose of cleaning the appliance and carrying away its contents into a drain.
NOTE — The nominal size of a cistern is the quantity of water discharged per flush.
2.1.59 Formation — The finished level of the excavation at the bottom of a trench or heading prepared to receive the permanent work.
2.1.60 French Drain or Rubble Drain — A shallow trench filled with coarse rubble, clinker, or similar material with or without field drain pipes.
2.1.61 Frost Line — The line joining the points of greatest depths below ground level up to which the moisture in the soil freezes.
2.1.62 General Washing Place — A washing place provided with necessary sanitary arrangement and common to more than one tenement.
2.1.63 Geyser — An apparatus for heating water with supply control on the inlet side and delivering it from an outlet.
2.1.64 Gully Chamber — The chamber built of masonry round a gully trap for housing the same.
2.1.65 Gully Trap — A trap provided in a drainage system with a water seal fixed in a suitable position to collect waste-water from the scullery, kitchen sink, wash basins, baths and rain water pipes.
2.1.66 Haunching — Outward sloping concrete support to the sides of a pipe or channel above the concrete bedding.
2.1.67 Heel Rest Bend or Duck-Foot Bend — A bend, having a foot formed integrally in its base, used to receive a vertical pipe.
2.1.68 High Altitudes — Elevations higher than 1 500 m above mean sea level (MSL).
2.1.69 Highway Authority — The public body in which is vested, or which is the owner of, a highway repairable by the inhabitants collectively; otherwise the body or persons responsible for the upkeep of the highway.
2.1.70 Horizontal Pipe — Any pipe of fitting which makes an angle of more than 45° with the vertical.
2.1.71 Hot Water Tank — A vessel for storing hot water under pressure greater than atmospheric pressure.
2.1.72 Inlet Hopper — A receptacle fitting for receiving refuse from each floor and dropping it into the chute.
2.1.73 Inspection Chamber — A water-tight chamber constructed in any house-drainage system which takes wastes from gully traps and disposes of to manhole with access for inspection and maintenance.
2.1.74 Interceptor — A device designed and installed so as to separate and retain deleterious, hazardous or undesirable matter from normal wastes and permit normal sewage or liquid wastes to discharge into the disposal terminal by gravity.
2.1.75 Interceptor Manhole or Interceptor Chamber — A manhole incorporating an intercepting trap and providing means of access thereto.
2.1.76 Invert — The lowest point of the internal surface of a pipe or channel at any cross-section.
2.1.77 Junction Pipe — A pipe incorporating one or more branches.
2.1.78 Lagging — Thermal insulation or pipes.
2.1.79 Licensed Plumber — A person licensed under the provisions of this Code.
2.1.80 Main Soil Pipe (MSP) — A pipe connecting one or more branch soil pipes to the drain.
2.1.81 Main Soil and Waste Pipe (MSWP) — A pipe connecting one or more branch soil and waste pipes to the drain.
2.1.82 Main Ventilating Pipe (MVP) — A pipe which receives a number of branch ventilating pipes.
2.1.83 Main Waste Pipe (MWP) — A pipe connecting one or more branch waste pipes to the drain.
2.1.84 Manhole — An opening by which a man may enter or leave a drain, a sewer or other closed structure for inspection, cleaning and other maintenance operations, fitted with suitable cover.
2.1.85 Manhole Chamber — A chamber constructed on a drain or sewer so as to provide access thereto for inspection, testing or clearance of obstruction.
2.1.86 Non-Service Laterine — Other than ‘service latrine’.
2.1.87 Offset — A pipe fitting used to connect two pipes whose axes are parallel but not in line.
2.1.88 Period of Supply — The period of the day or night during which water supply is made available to the consumer.
2.1.89 Pipe System — The system to be adopted will depend on the type and planning of the building in which it is to be installed and will be one of the following:
a) Single stack system (see Fig. 2) — The onepipe system in which there is no trap ventilation.
b) Single stack — Partially Vented — A via media between the one-pipe system and the single stack system (see one-pipe system, partially ventilated).
c) One-pipe system (see Fig. 3) — The system of plumbing in which the wastes from the sinks, baths and wash basins, and the soil pipe branches are all collected into one main pipe, which is connected, directly to the drainage system. Gully traps and waste pipes are completely dispersed with, but all the traps of the water closets, basins, etc, are completely ventilated to preserve the water seal.
d) One-pipe system — Partially vented (also called single stack, partially ventilated) — A system in which there is one soil pipe into which all water closets, baths, sinks, and
basins discharge. In addition, there is a relief vent, which ventilates only the traps of water closets.
e) Two-pipe system (see Fig. 4) — The system of plumbing in which soil and waste pipes are distinct and separate. The soil pipes being connected to the drain direct and waste pipes through a trapped gully. All traps of all appliances are completely ventilated in this system.
2.1.90 Pipe Work — Any installation of piping with its fittings.
3.1.9 Foul Air Exhaust
Each vent terminal shall extend to the outer air and be so installed as to minimize the possibilities of clogging and the return of foul air to the building, as it conveys potentially noxious or explosive gases to the outside atmosphere. All vent pipes shall be provided with a cowl.
3.1.10 Testing
The plumbing system shall be subjected to required tests to effectively disclose all leaks and defects in the work or the material.
3.1.11 Exclusion from Plumbing System
No substance that will clog or accentuate clogging of pipes, produce explosive mixtures, destroy the pipes or their joints, or interfere unduly with the sewage-disposal process shall be allowed to enter the drainage system.
3.1.12 Light and Ventilation
Wherever water closet or similar fixture shall be located in a room or compartment, it should be properly lighted and ventilated.
3.1.13 Individual Sewage Disposal Systems
If water closets or other plumbing fixtures are installed in buildings where connection to public sewer is not possible, suitable provision shall be made for acceptable treatment and disposal.
3.1.14 Maintenance
Plumbing systems shall be maintained in a safe and serviceable condition.
3.1.15 Accessibility
All plumbing fixtures shall be so installed with regard to spacing as to be accessible for their intended use
and for cleaning. All doors, windows and any other device needing access within the toilet shall be so located that they have proper access.
3.1.16 Fixture for Disabled
Special toilet fixtures shall be provided for the disabled with required fixtures and devices.
3.1.17 Structural Safety
Plumbing system shall be installed with due regard to preservation of the structural members and prevention of damage to walls and other surfaces.
3.1.18 Protection of Ground and Surface Water
Sewage or other waste shall not be discharged into surface or sub-surface water without acceptable form of treatment.
3.2 Water Supply Connection
3.2.1 Application for Obtaining Supply Connection
Every consumer, requiring a new supply of water or any extension or alteration to the existing supply shall apply in writing in the prescribed form (see Annex A) to the Authority.
3.2.2 Bulk Supply
In the case of large housing colonies or where new services are so situated that it will be necessary for the Authority to lay new mains or extend an existing main, full information about the proposed housing scheme shall be furnished to the Authority; information shall also be given regarding their phased requirements of water supply with full justification. Such information shall include site plans, showing the layout of roads, footpaths, building and boundaries and indicating thereon the finished line and level of the roads or footpaths and water supply lines and appurtenances.
3.2.3 Completion Certificate
On completion of the plumbing work for the water supply system, the licensed plumber shall give a completion certificate in the prescribed form (see Annex B) to the Authority for getting the water connection from the mains.
3.3 Drainage and Sanitation
3.3.1 Preparation and Submission of Plan
No person shall install or carry out any water-borne sanitary installation or drainage installation or any works in connection with anything existing or new buildings or any other premises without obtaining the previous sanction of the Authority.
The owner shall make an application in the prescribed form (see Annex C) to the Authority to carry out such a work.
3.3.2 Site Plan
A site plan of the premises on which the building is to be situated or any such work is to be carried out shall be prepared drawn to a scale not smaller than 1:500 (see Part 2 ‘Administration’). The site plan of the building premises shall show:
a) the adjoining plots and streets with their names;
b) the position of the municipal sewer and the direction of flow in it;
c) the invert level of the municipal sewer, the road level, and the connection level of the proposed drain connecting the building in relation to the sewer,
d) the angle at which the drain from the building joints the sewer; and
e) the alignment, sizes and gradients of all drains and also of surface drains, if any.
A separate site plan is not necessary if the necessary particulars to be shown in such a site plan are already shown in the drainage plan.
3.3.3 Drainage Plan
The application (3.3.1) shall be accompanied by a drainage plan drawn to a scale of not smaller than 1:100 and furnished along with the building plan (see Part 2 ‘Administration’). The plans shall show the following:
a) Every floor of the building in which the pipes or drains are to be used;
b) The position, forms, level and arrangement of the various parts of such building, including the roof thereof;
c) All new drains as proposed with their sizes and gradients;
d) Invert levels of the proposed drains with corresponding ground levels;
e) The position of every manhole, gully, soil and waste pipe, ventilating pipe, rain water pipe, water-closet, urinal, latrine, bath, lavatory, sink, trap or other appliances in the premises proposed to be connected to any drain and the following colours are recommended for indicating sewers, waste water pipes, rainwater pipes an existing work.
Description of Work
Colour
Sewers
Red
Waste water pipes and rain-water pipes
Blue
Existing work
Black
f) The position of refuse chute, inlet hopper and collection chamber.
3.3.3.1 In the case of an alteration or addition to an existing building, this clause shall be deemed to be
satisfied if the plans as furnished convey sufficient information for the proposals to be readily identified with previous sanctioned plans and provided the locations of tanks and other fittings are consistent with the structural safety of the building.
3.3.3.2 The plans for the building drainage shall in every case be accompanied by specifications for the various items of work involved. This information shall be supplied in the prescribed from given in Annex D.
3.3.4 In respect of open drains, cross-sectional details shall be prepared to a scale not smaller than 1:50 showing the ground and invert levels and any arrangement already existing or proposed for the inclusion of any or exclusion of all storm water from the sewers.
3.3.5 Completion Certificate
At the completion of the plumbing installation work, the licensed plumber shall give a completion certificate in the prescribed form, which is given in Annex E.
3.4 Licencing/Registration of Plumbers
3.4.1 Execution of Work
The work which is required to be carried out under the provisions of this Section, shall be executed only by a licensed plumber under the control of the Authority and shall be responsible to carry out all lawful directions given by the Authority. No individual shall engage in the business of plumbing unless so licensed under the provisions of this Section.
3.4.1.1 No individual, firm, partnership or corporation shall engage in the business of installing, repairing or altering plumbing unless the plumbing work performed in the course of such business is under the direct supervision of a licensed plumber.
3.4.2 Examination and Certification
The Authority shall establish standards and procedure for the qualification, examination and licensing of plumbers and shall issue licences to such persons who meet the qualifications thereof and successfully pass the examination.
3.4.3 For guidelines for registration of plumbers including the minimum standards for qualifications for the grant of licences, reference may be made to good practice [9-1(1)].