In ULB the building height shall not normally be more than 14.50 meters (fourteen and half). But in the case of any building exceeding 14.50 meters in height, the ULB, for reasons to be recorded in writing and with the previous approval of the State Government with the support of the Technical Appraisal Committee (TAC) constituted as per sub-rule 8 of this rule, may sanction such proposal(s) as special case if not otherwise covered by any law for the time being in force. In such cases the following special rules shall be applicable in addition to other rules under the Act:-
(1) no building exceeding 14.5 (fourteen and half) meters height shall be allowed on private or public street of less than 15.00 meters in width;
(2) for every category of building referred to in rule 49(2) and exceeding 14.5 (fourteen and half) meters in height shall have a front open space of not less than 20% of the height of the building or 6 meters at its narrowest part, whichever is less subject to minimum as specified in rule 48(2).
(3) (a) every building exceeding fourteen and half meters but not exceeding 18.0 (eighteen) meters in height shall have a rear open space at ground along the entire width of the building forming an integral part of site of a minimum width of five meters;
(b) every building exceeding 18.0 (eighteen) meters in height shall have a rear open space at ground along the entire width of the building forming an integral part of the site of 20% of the height of the building subject to the minimum of five meters;
(4) (a) the minimum side open space of a building exceeding 14.5(fourteen and half) meters but not exceeding 18.0(eighteen) meters in height shall be 3 meters and 50 centimeters on either side or more;
(b) the minimum side open space of a building exceeding eighteen meters in height shall be 20% of the height of the building subject to the minimum of five meters and fifty centimeters on either side;
(c) in the case of a building of more than 24 meters in depth and not exceeding 18 meters in height one of the side shall be at least 4 meters in width;
(5) (a) in case the whole of one side or part of at least two sides of every room excepting bath, water-closets and store-room, is not abutting either the front,
rear or side open spaces, it shall abut an inner courtyard whose minimum width shall be 20% of the height of the building or 3 meters, which ever is more;
(b) for ventilating water closet in bathroom such water closet or bathroom or kitchen or any room not intended for human habitation, if not opening on to front, rear, side or interior open space, shall be up to a ventilation shaft, the size of which shall not be less than the values given below :
| Height of building (meters) | Area of ventilation shaft (sq. meters) | Minimum width of shaft (meters) |
|---|---|---|
| Above 14.00 but not more than 18.00 | 6.00 | 2.40 |
| Above 18.00 | 8.00 | 2.40 |
For building of height of more than 14.50 meters in height a mechanical ventilation system shall be installed besides the provision of ventilation shaft;
(c) if there be building other than boundary wall of not more than three sides of a court yard, the minimum width shall be 20% of the height of the building or 2.50 meters which ever is more;
(6) (a) for every building exceeding fourteen and half meters in height, the Floor Area Ratio shall be as specified in the table below :
TABLE
Maximum Permissible Floor Area Ratio (FAR)
| Width of means of Access (meters) | Residential Building | Institutional, Business and other Buildings | |
| Commercial Zone, if any | Other Zone | ||
| 1. Above 14.5 to 20.00 | 2.50 | 2.75 | 2.50 |
| 2. Above 20.00 | 2.75 | 3.00 | 2.75 |
(b) while calculating the floor area under this Chapter, the following shall be excluded namely :-
(i) stair cover not exceeding 2.4 meters in height,
(ii) lift machine room as per latest edition of the National Building code,
(iii) roof tanks with their support, the height shall not exceeding 1.8 meters,
(iv) chimney, ventilating, air-conditioning and service equipment attached to the building:
Provided that the aggregate area of these structures mentioned at (i) to (iv) above shall not exceed one-third area of the roof upon which these are erected,
(v) the area of covered car parking spaces as may have been provided for the required number of car parking, spaces in accordance with rule 50, and for this calculation the area required for one car parking space shall be taken as 20 sq. meters inclusive of all circulation spaces.
(7) for construction of steel towers, the criteria specified for buildings above 14.5 meters in height shall be followed.
(8) A Technical Appraisal Committee (TAC) as provided in rule 50 shall be constituted by the Urban Development Department which will support the State Government in giving approval of building plan having height more than 14.5 meter.
PART-V Regulation for more than one building in one plot
- Regulation for more than one building in one plot, existing building and the buildings under Govt. approved schemes:-
(1) (a) Every building on a plot containing more than 1(one) building shall abut an internal road connecting the means of access of the plot.
(b) The minimum width of such internal roads shall be 3.50 meters where internal road of 3.50 meters in width is not possible to be provided due to an existing building constructed prior to the enforcement of these rules, a building of not more than 8.0 meters in height may be allowed, provided that the width of the internal road shall not be less than 1.20 meters.
(c) The maximum permissible height of any building on a plot shall be determined by the width of the means of access on which the plot abuts according to the table given in sub-rule(3) of rule - 48.
(d) The minimum width and the maximum length of all such internal roads shall be as prescribed in the table below:
| Width of means of access | Maximum length of the means of access | |
| For means of access closed at one end | For means of access open to street at both ends | |
| (i) 3.50 meters and above but not more than 7.00 meters | 25.00 meters | 75.00 meters |
| (ii) Above 7.00 meters but not more than 10.00 meters | 50.00 meters | 150.00 meters |
| (iii) Above 10.00 meters | No restriction | No restriction |
(e) In case the buildings within a plot which are not of the same occupancy, an individual building of any particular occupancy shall comply with the rules governing such occupancy except the provisions regarding ground coverage which shall be in accordance with sub-rule(2) of this rule.
(2) Ground Coverage shall be as laid down below :-
for plots measuring 5,000 sq. mts or more in area, the maximum permissible ground coverage shall be 45% for residential or education buildings and 35% for buildings of other use groups or for buildings with mixed occupancies :
provided that the provisions of rule 47 shall be applicable to plots measuring less than 5,000 sq. meters.
(3) open space for Building shall be as laid down below :-
(a) every building shall have minimum external open space prescribed in Rule 49, provided that on these open spaces internal roads may be constructed.
(b) for plots measuring more than 5000 sq. meters in area, provision of 8% of the total area of the plot is to be kept as public open space. The width of each such open space shall not be less than 10.00 meters and each such open space shall abut a street having a width not less than 7.00 meters. The minimum area of each of such open space in one parcel shall be 400 sq. meters This open space shall be in addition to the land required for providing the means of access to the individual plots as prescribed in rule 46.
(c) for plot measuring more than 25000 sq. meters in area provision of 7% of the total area of the plot shall be reserved for use for facilities like School, Health
Centres, Market, Police Outpost with both Post Office, Power Sub-station, Transport Terminal water Treatment plant, Sewerage Treatment plant and the like, such land shall abut a street having a width of not less than 10.00 meters in addition to the land necessary for means of access and for open spaces sanctioned in clause(b) of this sub-rule.
(4) The parking provision shall be the same as stipulated in rule 49.