3.1 General
The materials used in masonry construction shall be in accordance with Part 5 ‘Building Materials’.
3.2 Masonry Units
Masonry units used in construction shall conform to accepted standards [6-4(1)].
3.2.1 Masonry units may be of the following types:
a) Common burnt clay building bricks,
b) Burnt clay fly ash building bricks,
c) Pulverized fuel ash lime bricks,
d) Stones (in regular sized units),
e) Sand-lime bricks,
f) Concrete blocks (solid and hollow),
g) Lime based blocks,
h) Burnt clay hollow blocks,
j) Gypsum partition blocks,
k) Autoclaved cellular concrete blocks, and
m) Concrete stone masonry blocks.
1 Gypsum partition blocks are used only for construction of non-load bearing partition walls.
2 Use of other masonry units, such as, precise stone blocks, fly-ash-lime-gypsum bricks, stabilized mud blocks and other bricks/blocks not covered by the above specifications may also be permitted based on test results.
3.2.2 Masonry units that have been previously used shall not be re-used in brickwork or blockwork construction, unless they have been thoroughly cleaned
and conform to this Section for similar new masonry units.
3.3 Mortar
Mortar for masonry shall conform to accepted standard [6-4(2)].
3.3.1 Mix proportions and compressive strengths of some of the commonly used mortars are given in Table 1.
| Sl No. | Grade of Mortar | Mix Proportions (by Loose Volume) | Minimum Compressive Strength at 28 Days in N/mm ² | ||||
| Cement | Lime | Lime Pozzolana Mixture | Pozzolana | Sand | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
| 1 | H1 | 1 | (1)/(4) C or B | 0 | 0 | 3 | 10 |
| 2(a) | H2 | 1 | (1)/(4) C or B | 0 | 0 | 4 | 7.5 |
| 2(b) | 1 | (1)/(2) C or B | 0 | 0 | 4(1)/(2) | 6.0 | |
| 3(a) | M1 | 1 | 0 | 0 | 5 | 5.0 | |
| 3(b) | 1 | 1 C or B | 0 | 0 | 6 | 3.0 | |
| 3(c) | 0 | 0 | 1 (LP-40) | 0 | 1(1)/(2) | 3.0 | |
| 4(a) | M2 | 1 | 0 | 0 | 0 | 6 | 3.0 |
| 4(b) | 1 | 2 B | 0 | 0 | 9 | 2.0 | |
| 4(c) | 0 | 1 A | 0 | 0 | 2 | 2.0 | |
| 4(d) | 0 | 1 B | 0 | 1 | 1 | 2.0 | |
| 4(e) | 0 | 1 C or B | 0 | 2 | 0 | 2.0 | |
| 4(f) | 0 | 0 | 1 (LP-40) | 0 | 1(3)/(4) | 2.0 | |
| 5(a) | M3 | 1 | 0 | 0 | 0 | 7 | 1.5 |
| 5(b) | 1 | 3 B | 0 | 0 | 12 | 1.5 | |
| 5(c) | 0 | 1 A | 0 | 0 | 3 | 1.5 | |
| 5(d) | 0 | 1 B | 0 | 2 | 1 | 1.5 | |
| 5(e) | 0 | 1 C or B | 0 | 3 | 0 | 1.5 | |
| 5(f) | 0 | 0 | 1 (LP-40) | 0 | 2 | 1.5 | |
| 6(a) | L1 | 1 | 0 | 0 | 0 | 8 | 0.7 |
| 6(b) | 0 | 1 B | 0 | 1 | 2 | 0.7 | |
| 6(c) | 0 | 1 C or B | 0 | 2 | 1 | 0.7 | |
| 6(d) | 0 | 0 | 1 (LP-40) | 0 | 2(1)/(4) | 0.7 | |
| 6(e) | 0 | 0 | 1 (LP-20) | 0 | 1(1)/(2) | 0.7 | |
| 7(a) | L2 | 0 | 1 B | 0 | 0 | 3 | 0.5 |
| 7(b) | 0 | 1 C or B | 0 | 1 | 2 | 0.5 | |
| 7(c) | 0 | 0 | 1 (LP-7) | 0 | 1(1)/(2) | 0.5 | |
1 Sand for making mortar should be well graded. In case sand is not well graded, its proportion shall be reduced in order to achieve the minimum specified strength.
2 For mixes in Sl No. 1 and 2, use of lime is not essential from consideration of strength as it does not result in increase in strength. However, its use is highly recommended since it improves workability.
3 For mixes in Sl No. 3(a), 4(a), 5(a) and 6(a), either lime C or B to the extent of ¼ part of cement (by volume) or some plasticizer should be added for improving workability.
4 For mixes in Sl No. 4(b) and 5(b), lime and sand should first be ground in mortar mill and then cement added to coarse stuff.
5 It is essential that mixes in Sl No. 4(c), 4(d), 4(e), 5(d), 5(e), 6(b), 6(c), 7(a) and 7(b) are prepared by grinding in a mortar mill.
6 Mix in Sl No. 2(b) has been classified to be of same grade as that of Sl No. 2(a), mixes in Sl No. 3(b) and 3(c) same as that in Sl No. 3(a), mixes in Sl No. 4(b) to 4(f) same as that in Sl No. 4(a), even though their compressive strength is less. This is from consideration of strength of masonry using different mix proportions.
7 A, B and C denote eminently hydraulic lime, semi-hydraulic lime and fat lime respectively, as specified in appropriate standards listed in Part 5 ‘Building Materials’.