Means the quotient of the ratio of the combined gross built-up area of all floors, to the total area of the Building-unit.
Floor Space Index = Total built-up area of all floors/ Area of the Building-unit
1. Permissible F.S.I.
Means the basic F.S.I. permitted by the Competent Authority as a matter of right.
2. Base F.S.I.
Means the base F.S.I. permitted in a given zone by the Competent Authority as a matter of right.
3. Chargeable F.S.I.
Means the F.S.I. available by payment
4. Maximum Permissible F.S.I.
Means the maximum permissible F.S.I. which includes permissible F.S.I. and Chargeable F.S.I.
5. Utilised Chargeable F.S.I.
Means the amount of F.S.I.used, that is paid for and purchased by the applicant.
6. Total Utilised F.S.I.
Means the total Utilized F.S.I.
Provided that the following shall not be counted towards computation of F.S.I.
-
All interior open‐to‐sky spaces such as courtyards and chowk, utility ducts in any form, shape and size required by Regulations.
-
Area used for parking at basement or hollow‐plinth.
-
Basement exclusively used for parking shall have minimum height of 2.80 m and maximum height of 3.80 m, measured from finished basement floor level to finished plinth level. Only in case of mechanised parking, there is no restriction on maximum height or number of basement floors used for parking purpose.
-
For basement provided exclusively for parking, other permissible uses shall be permitted up to a maximum area of 25% of the total built‐up area of the basement floor. This non parking area shall be calculated towards the computation of F.S.I.
-
Hollow plinth provided for parking with the following conditions:
(a) Such hollow plinth shall be provided within the building‐unit except on road‐side facade.
(b) Hollow plinth provided for the purpose of parking shall have maximum height of 3.50 m from finished ground level to finished first floor level and a minimum height of 3.00 m from finished ground level to finished first floor level.
(c) Hollow Plinth can have provision for electric meter room, room for telephone distribution board, bathroom, water room, servant room, and security cabin and entrance foyer if the total area does not exceed 15 sq.m. This area shall not be considered towards computation of F.S.I.
-
Loft provided as per up to a maximum of 30% of the enclosing space.
-
Staircase and stair cabin provided as per the following conditions :
(a) Staircase with maximum intermediate landing width equal to the width of stair,
(b) Maximum landing width at floor level shall be three times the width of stair (x m) including additional space (0.5x m) provided at either side of the stair landing as common area.
- Lift, lift well with lift cabin, stair cabin, lift landing of lift well and water tank, including the walls provided as per Performance the following conditions:
a. The width of the lift landing shall be considered equal to the maximum width of the lift well including walls (x m) with an additional space (0.5x m) at either side of the lift provided as common area.
b. The depth of the lift landing shall be two times the maximum width of the lift well including walls (x m).
-
The width of the lift landing shall be considered twice the width of the lift well including walls including additional space provided at either side of the landing, and the depth shall be of twice the width of the lift well.
-
Vehicular ramps and pedestrian ramps provided.
-
Electric room and electric substation as specified by Competent Electric Company.
-
Open‐to‐sky space used for solar‐water heating system, outdoor units for air‐conditioners or mechanical ventilation shall be exempt from F.S.I.
Means a foundation unit constructed in brick work, stone masonry or concrete under the base of a wall column for the purpose of distributing the load over a large area.
2.57 Foundation
Means the part of the structure which is in direct contact with and transmitting loads to the ground.
2.58 Front
Means the main frontage of a Building-unit on the road-side. For Building-units abutting two or more roads, the side along the wider road shall be considered as the front.
2.59 Fuelling Station
Means a place for retail business engaged in supplying and dispensing of fuel products to consumers, essential for the normal operation of automobiles.
2.60 Gamtal
Means all land that has been included by the Government/ Collector within the site of village, town or city on or before the date of declaration of intention to make a Town Planning Scheme or publication of Draft Development Plan-2035 under section 13 of the Act. Such land shall not include any other land which may subsequently be included within the site of any village by the Government/Collector under the provisions of Land Revenue Code.
2.61 Garage-private
Garage-Private means a building or a portion thereof designed and used for the parking of vehicles.
2.62 Garage-public
Garage-Public means a building or portion thereof, designed other than as a private garage, operated for gain, designed and/or used for repairing, servicing, hiring, selling or storing or parking motor-driven or other vehicles.
2.63 Garden
Means a public recreation area or park usually ornamented with plants and trees along with landscape furniture.
2.64 Ground Coverage
Means the ground area covered by a building including cantilevered portion on any floor, excluding cut-out (open-to-sky) if any.
2.65 Ground Level
Means the level of the crown of the existing adjacent constructed road or the existing ground level or the high flood level, whichever is higher as may be decided by Competent Authority.
High flood level shall be decided by Competent Authority.
2.66 Guiding Floor Material
Means flooring material used to give the directional effect or warn a person at critical places and attract the attention of visually impaired persons. The material may be guiding by colour and brightness that is conspicuously different from that of the surrounding floor material or by texture that emits different sounds.
2.67 Habitableroom
Means a room occupied or designed for occupancy for human habitation and uses incidental thereto, including a kitchen if used as a living room, but excluding a bath-room, water closet compartment, laundry, serving and storing, pantry, corridor, cellar, attic, store-room, poojaroom and spaces not frequently used.
2.68 Hazardous Building or Industry
Means a building or place or part thereof used for:
-
Storage, handling, manufacture or processing of radio-active substances or of highly combustible or explosive materials or products which are liable to burn with extreme rapidity and/or producing poisonous fumes.
-
Storage, handling, manufacture or processing of, which involves highly corrosive, toxic obnoxious alkalis, acids, or other liquids, gases or chemicals producing flame, fumes, and explosive mixtures or which result in division of matter into fine particles and capable of spontaneous ignition.
2.69 Hazardous Material
Means any of the following materials: Radioactive substances, Inflammable, combustible or explosive materials that may produce poisonous fumes or explosions on storage, handling, processing or manufacturing. Corrosive, toxic, obnoxious alkalis or acids, Chemicals which may produce irritant, corrosive or poisonous gases on explosion or spontaneous combustion.