| Sl.No. | Fixtures | Public Rooms | Non-Residential Staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Toilet suite comprising one WC, washbasin with shower or a bath tub | Individual guest rooms with attached toilets | - | ||
| Guest Rooms with Common Facilities | |||||
| (ii) | Water-closets | 1 per 100 persons upto 400 Over 400 add at 1 per 250 or part there of | 2 per 100 persons upto 200 Over 200 add at 1 per 100 or part there of | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 |
| (iii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part there of in the vicinity of water-closets and urinals | |||||
| (iv) | Urinals | 1 per 50 persons or part there of | - | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | - |
| (v) | Washbasins | 1 per WC/ Urinal | 1 per WC | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-57 |
| (vi) | Bath (Showers) | 1 per 10 persons or part thereof | - | - | |
| (vii) | Cleaner's sink | 1 per 30 rooms, minimum 1 per floor | |||
| (viii) | Kitchen sink | 1 per kitchen | |||
NOTE: (1) Some W.C.'s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
(3) Provision for additional and special fittings where required shall be made.
PART-I]
277
10. RESTAURANTS
| Sl.No. | Fixtures | Public Rooms | Non-Residential Staff | ||
| Male | Female | Male | Female | ||
| (1) | (2) | (3) | (4) | (5) | (6) |
| (i) | Water-closets | 1 per 50 seats upto 200Over 200 add at 1 per 100 or part thereof | 2 per 50 seats upto 200Over 200 add at 1 per 100 or part thereof | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| (iii) | Urinals | 1 per 50 persons or part thereof | - | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | - |
| (iv) | Washbasins | 1 per W.C. | 1 per W.C. | 1 per W.C. | 1 per W.C. |
| (v) | Cleaner's sink | 1 per each restaurant | |||
| (vi) | Kitchen sink / Dish washer | 1 per kitchen | |||
Note: (1) Some W.C.'s may be European style if desired.
(2) Male population may be assumed as two-third and female population as one-third.
(3) Provision for additional and special fitting where required shall be made.
[ PART-I]
- SCHOOLS AND EDUCATIONAL INSTITUTIONS
| Sl.No. | Fixtures | Nursery School | Non-Residential | Residential | ||
| Boys | Girls | Boys | Girls | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) |
| (i) | Water-closet | 1 per 15 pupils or part thereof | 1 per 40 pupils or part thereof | 1 per 25 pupils or part thereof | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | ||||||
| (iii) | Urinals | - | 1 per 20 pupils or part thereof | - | 1 per 25 pupils or part thereof | - |
| (iv) | Washbasins | 1 per 15 pupils or part thereof | 1 per 60 pupils or part thereof | 1 per 40 pupils or part thereof | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| (v) | Bath/Showers | 1 per 40 pupils or part thereof | - | - | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| (vi) | Drinking water Fountain or taps | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof |
| (vii) | Cleaner's sink | 1 per each floor | ||||
Note: (1) Some W.C.'s may be European style if desired.
(2) For teaching staff, the schedule of fixtures to be provided shall be the same as in case of office building.
12. HOSTELS
| Sl.No. | Fixtures | Resident | Non-Resident | Visitor / Common Rooms | |||
| Males | females | Males | females | Males | females | ||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
| (i) | Water-closet | 1 per 8 or part thereof | 1 per 6 or part thereof | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 Per 100upto 400Over 400add at 1 per 250 | 2 Per 100upto 200Over 200add at 1 per 100 |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||||
| (iii) | Urinals | 1 per 25 or part thereof | - | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | - | 1 per 50 or part thereof | - |
| (iv) | Wash basins | 1 per 8 persons or part thereof | 1 per 6 persons or part thereof | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 per WC / Urinal | 1 per WC |
| (v) | Bath / Showers | 1 per 8 persons or part thereof | 1 per 6 persons or part thereof | - | - | - | - |
| (vi) | Cleaner's sink | 1 per each floor | |||||
NOTE: (1) Some W.C.'s may be European style if desired.
PART-I
279
13. SHOPS, FRUIT AND VEGETABLE MARKETS
| Sl.No. | Fixtures | Shop Owners | Common Toilets in Market Building | Public Toilet for floating population | |||
| Males | females | Males | females | Males | females | ||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
| (i) | Water-closet | 1 per 8 or part thereof | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 Per 50 (Minimum 2) | 1 Per 50 (Minimum 2) | |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided in receiving / sale area of each shop and for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||||
| (iii) | Urinals | - | - | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | - | 1 per 50 | - |
| (iv) | Washbasins | 1 per 8 persons or part thereof | 1 for upto 152 for 16-353 for 36-654 for 66-100 | 1 for upto 122 for 13-253 for 26-404 for 41-57 | - | - | |
| (v) | Bath/Showers | 1 per 8 persons or part thereof | 1 per 6 persons or part thereof | - | - | 1 per 50 persons | 1 per 50 persons |
NOTE:
(1) Toilet facilities for individual buildings in a market should be taken same as that for office buildings.
(2) Common toilets in the market buildings provide facilities for persons working in shops and their regular visitors.
(3) Special toilet facilities for a large floating population of out of town buyers / sellers, labour, drivers of vehicles for whom special toilet (public toilets).
[ PART-I]
14. AIRPORTS AND RAILWAY STATIONS
| Sl.No. | Fixtures | Junction Stations, Intermediate Stations and Bus Stations | Terminal Railway and Bus Stations | Domestic and International Airports | |||
| Males | females | Males | females | Males | females | ||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) |
| (i) | Water-closet | 3 for up to 1000 Add 1 per additional 1000 or part thereof | 4 for up to 1000 Add 1 per additional 1000 or part thereof | 4 for up to 1000 Add 1 per additional 1000 or part thereof | 5 for up to 1000 Add 1 per additional 1000 or part thereof | Minimum 2 For 200-5 For 400 -9 For 600 -12 For 800 -16 For 1000-18 | Minimum 2 For 200-8 For 400 -15 For 600- 20 For 800- 26 For 1000-29 |
| (ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||||
| (iii) | Urinals | 4 for up to 1000 Add 1 per additional 1000 | - | 6 for up to 1000 Add 1 per additional 1000 | - | 1 per 40 or part thereof | - |
| (iv) | Washbasins | 1 per Wc/ Urinal | 1 per Wc | 1 per Wc/Urinal | 1 per Wc | 1 per Wc/Urinal | 1 per Wc |
| (v) | Bath/ Showers | 2 per 1000 | 3 per 1000 | 4 per | 1000 | ||
| (vi) | Drinking water fountain or taps (in common lobby for male / female) | 2 per 1000 or part thereof | 3 per 1000 or part thereof | 4 per 1000 or part thereof | |||
| (vii) | Cleaner's sink | 1 per toilet compartment with 3 WC's | 1 per toilet compartment with 3 WC's | 1 per toilet compartment with 3 WC's | 1 per toilet compartment with 3 WC's | 1 per toilet compartment with 3 WC's | 1 per toilet compartment with 3 WC's |
| (viii) | Toilet for Disable | 1 per 4000 | 1 per 4000 | ||||