For the purpose of calculating FAR, cantilevered, permitted roof projections, lift room, mumty, balcony, basement or any floor if used for parking, services and storage, stilt area (unenclosed) proposed to be used for parking/ pedestrian plaza only, open staircase (without mumty), terrace with or without access, fire staircase, atrium, water tank, open courtyard of permitted size shall not be counted towards FAR:
Provided, area under shaft, chutes, lift well and staircase from stilt to next floor shall be counted towards FAR only at once on ground floor:
Provided in case the ventilation shaft area is more than 3 square metres, it shall not be counted in FAR;
(xlii) “form” means a form appended to this Code;
(xliii) “footwear manufacturing industry” means the industrial units primarily engaged in the design, cutting, assembly and manufacturing of footwear from finished leather, fabric, rubber and their variants and shall include other similar products such as belts, purses, bags, suit-cases, brief cases etc. but shall not include the processing and tanning of leather and its variants;
(xliv) “foundation” means a part of a structure which is below the lower most floor and which provides support for superstructure and which transmit load of the superstructure to the bearing surface;
(xlv) “framed building” shall mean a building, the external walls of which are constructed of a frame of timber, iron, reinforced cement concrete or steel and such framing consisting of posts or columns and beams, filled in, wholly or partially covered with bricks, stones, iron plates or other materials and the stability of which depends upon such framing;
(xlvi) “front” as applied to a building shall mean generally the portion facing the street from which it has access and in case of doubt as determined by the Competent Authority;
(xlvii) “garage” shall mean a building or portion thereof used or intended to be used for shelter, storage or parking of a wheeled vehicle;
(xlviii) “ground coverage” means built up area covered at ground level:
For the purpose of calculating ground coverage area under shaft, chute, lift well and staircase shall be counted towards ground coverage: Provided ventilation shaft area more than 3 square metres, fire staircase, atrium and open courtyard of permitted size, shall not be counted in ground coverage;
(xlix) “group housing” means a building designed and developed in the form of flats for residential purpose or any building ancillary to group housing;
(l) “habitable room” means a room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, but not including bathrooms, water-closet compartments, laundries, serving and store pantries, corridors, cellars, attics, and spaces that are not used frequently or during extended periods.
(li) “height” as applied to a building means vertical measurement of the building measured from the finished mean level of the street where such street exists or from the mean level of the ground adjoining the outside of the external walls to half the height of the roof in the case of sloping roofs and to the highest level of the building in case of building with flat roof, excluding the projected portions of mumties, flues, ducts, building maintenance unit, machine room,
minarets, water tank and parapets not exceeding 1.2 metre in height. Architectural features serving no other functions except that of the decoration shall be excluded for the purpose of taking heights. Height as applied to a room shall mean the vertical measurement from the top surface of the floor to the lowest surface of the ceiling of the same room, joist and beams being allowed to project beneath the ceiling, and in the case of a sloping ceiling, the height shall be the mean height of any such room;
(lii) “integrated commercial complex” means building containing apartments sharing common services and facilities and having their undivided share in the land and meant to be used for office or for practicing of any profession or for carrying on any occupation, trade, business or such other type of independent use as may be prescribed;
(liii) “layout plan” means a plan of the entire site showing location of plots/ building blocks, roads, open spaces, entry/ exit, parking, landscaping etc. indicating activity of all land or partial;
(liv) “load” includes,-
(a) ‘dead load’ i.e. weight of all permanent stationary construction becoming a part of the structure; and
(b) ‘live load’ i.e. all load except dead load that may be imposed on a structure including wind loads shall be considered as live upon it;
(lv) “loft” shall mean an intermediate space between two floors on a residual space with maximum height of 1.5 metres and which is constructed or adopted for storage purposes only;
(lvi) “material change of use” shall mean a change from one class building to another;
(lvii) “mean level of street” means the average level of all points on the surface of the street from which the site derives its access measured at the centre line of street;
(lviii) “mezzanine floor” means an intermediate floor, between two floors, with area restricted to 1/2(half) of the area of the lower floor and with a minimum clear height of 2.3 metres and shall not be lower than 2.3 metres (clear height) above floor level;
(lix) “mumti” means a small structure erected on the roof of a building to protect such staircase from weather;
(lx) "non-nuisance professional consultancy services" shall include Doctors (without nursing home), Lawyers, Tax Consultants, Architects & Town Planners (without studio), Contractor Consultants, Chartered Accountants, Company Secretaries,
Property Consultants, Ayurvedic and Homeopathic Practitioner, Psychiatrist, Clinical Psychologist and Tourist Guides;
(lxi) “occupancy” means the main purpose for which a building or a part of building is used or intended to be used;
(lxii) “open space” means a space forming an integral part of the plot left open to sky;
(lxiii) “parapet” means a low wall built along the edge of a roof or a floor not more than 1.2 metre in height for buildings upto 15 metres and 1.5 metres for buildings above 15 metres;
(lxiv) “parking” means a space enclosed or unenclosed, to park vehicles together with a driveway connecting the parking space with a street permitting ingress and egress of the vehicles;
(lxv) “partition” means a wall which bears no load other than its own weight;
(lxvi) “party wall” means a common wall partly constructed on the plot of land, and partly on the adjoining plot and serving both structurally or otherwise;
(lxvii) “plinth” means the portion or structure between the surface of the surrounding ground and surface of the floor immediately above the ground;
(lxviii) “plinth area” means the built up covered area measured at floor level on the basement or of any storey;
(lxix) “plinth height” means the level of ground floor above the street level surface of the surrounding ground and surface of the floor immediately above the ground;
(lxx) “plinth level” means the level of the ground floor of building;
(lxxi) “plot” means piece of land or site enclosed by definite boundaries;
(lxxii) “porch” means a covered surface supported on pillars or otherwise for the purpose of pedestrian or vehicular approach to a building.
(lxxiii) “premises” means messuages, buildings, land easements and hereditaments of any tenure;
(lxxiv) “proof consultant” shall be a person who is a Structural Engineer or a Group/ Firm of Structural Engineers having post-graduate qualification in structural engineering with ten years experience in structural design and evaluation thereof, for multi-storeyed and specialized structure, and/ or an institute of the following type, employed for evaluation/ checking of the structural design of the buildings referred to in the relevant Form BR-V(A2) for all buildings above 15 metres height (including stilt) (Please see Appendix “A”):-
(a) Institute of Structural Engineers (India).
(b) Central Building Research Institute, Roorkee.
(c) Various engineering institutes, like
I. Indian Institute of Technology;
II. Punjab Engineering College, Chandigarh;
III. National Institute of Technology;
IV. Any other institute of repute;
(lxxv) “public sewer” means a sewer line owned and maintained by competent authority for carrying out the sewage;
(lxxvi) “public street” means any street heretofore levelled, paved, metalled, channelled, sewered or repaired out of municipal or other public funds, unless before such work was carried out, there was an agreement with the proprietor that the street shall not thereby become a public street, or unless such work was done without the implied or express consent of the proprietor.
(lxxvii) “rain water pipe” means a pipe or drain used or constructed to be used solely for carrying off rain water directly from roof surfaces;
(lxxviii) “rear” as applied to a building means that portion which is on the opposite side of the ‘front’;
(lxxix) “self-certification” means seeking approval of building plans duly prepared and certified by Architect as per relevant building Code, zoning plan and as per parameters/ policies issued by the Competent Authority from time to time;
(lxxx) “service floor” means the floor of a building with maximum height of 2.4 metres, where service equipment, utility lines and various machinery are located;
(lxxxi) “setback” means a line usually parallel to the plot boundary as laid down in each case by the Competent Authority beyond which nothing can be constructed towards the plot boundary unless specifically allowed by Competent Authority;
(lxxxii) “site” same as “plot” defined at Code 1.2(1)(lxxi);
(lxxxiii) “site plan” means a detailed plan showing the proposed placement of structures, parking areas, open space, landscaping, and other development features, on a parcel of land, as required by specific sections of the building Code;
(lxxxiv) “storage tank” means a tank or a cistern for storage of water which is connected to water main by means of a supply pipe;
(lxxxv) “storey” mean the portion of a building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it;
(lxxxvi) “stilt” means poles, posts or pillars or columns used to allow a structure or building to stand at a distance above the ground;
(lxxxvii) “street line” means the line defining the side limits of a street;
(lxxxviii) "Structural Engineer" means a person who is a post graduate in structural engineering from a recognized Indian or Foreign University or Corporate Member of Civil Engineering Division of the Institute of Engineers of India or equivalent Institute with a minimum of three years experience in structural engineering practice in designing structures and field work and/ or registered as such with the Competent Authority, employed for preparation of structural design of buildings upto 15 metres height. However, only the Structural Engineer Possessing post graduate qualification in structural engineering along with a minimum of 3 years experience in the design of multi storey and specialized structure and/ or registered with Competent Authority shall be employed to undertake and submit the structural design of buildings other than residential and commercial buildings upto 15 metres height (including stilt), as per the requirements of the relevant Form BR-V(A2) (Please see Appendix “A”).
(lxxxix) “structural wall” means a load bearing wall or wall that carries load in addition to its own load;
(xc) “sub-soil drain” mean a drain used or constructed to be used solely for conveying to any sewer (either directly or through another drain) any water that may percolate, through the subsoil;
(xci) “sun-shade” means a slope or horizontal or vertical structure over hanging, usually provided over openings on external wall to provide protection from sun and rain and shall not be used for human habitation;
(xcii) “temporary building” mean a building built of unburnt bricks, burnt bricks without mortar, corrugated iron, bamboo, thatch, wood, board or plywood but shall not include a building built of burnt bricks, cement blocks or stones laid in mortar;
(xciii) “Town Planner” means a person holding valid Associate Membership of the Institute of Town Planners or Graduate or Post-Graduate Degree in Town and Country Planning from a recognized Indian or Foreign Institute/ University.
(xciv) “verandah” means a covered area with at least one side open to the outside with the exception of 1.2 metre high parapet on the upper floors to be provided on the open side;
(xcv) “water closet” means a privy with arrangement for flushing the pan with water. It does not include a bathroom;
(xcvi) “zoning plan” mean the detailed layout plan of the sector or municipal area or a part thereof or of individual sites to whom permission for CLU has been granted, maintained in the office of the Competent Authority showing the sub division of plots, open spaces, streets and other features and in respect of each
plot, permitted land use, building lines and restrictions with regard to use and development of each plot in addition to those laid down in the building Code, further same can also be prepared/ maintained for industrial plots, if need arises.