Reporting of Contravention of Building Regulations 47
Relaxation 47
ANNEXURE -A.... 48
ANNEXURE -A-I.... 49
ANNEXURE -B.... 50
ANNEXURE -B-I.... 54
ANNEXURE -C.... 56
ANNEXURE -C-I.... 57
ANNEXURE -C-II.... 58
ANNEXURE -D.... 59
ANNEXURE -E.... 60
ANNEXURE -F.... 62
ANNEXURE -G.... 65
ANNEXURE -H.... 76
CHAPTER - I
Definitions and Administration
1 Short title, extent and commencement:—
(1) These regulations may be called the Aizawl Municipal Council Building Regulations, 2011.
(2) They shall apply to all the areas covered by the Aizawl Municipal Council.
(3) They shall come into force on such date as the Aizawl Municipal Council may notify by notification in the Official Gazette.
2 Applicability: — They shall apply to the building activities given below, namely:
(1) when a building is newly erected, to the design and construction of the building;
(2) where the whole or any part of a building is dismantled / repaired;
(3) where the whole or any part of a building is demolished, and
(4) where alteration or addition to a building is made.
15Responsibilities and powers of Local Councils:—
It shall be the responsibility of the concerned Local Council to ensure general compliance with the provisions of these Regulations by everybody in its jurisdiction. In particular, the Local Council shall ensure that no person constructs a house or modifies or alters it without obtaining permission from the Aizawl Municipal Council and that the requirements of set backs for front, sides and rear of a building are strictly observed. The concerned Local Council is, by virtue of this provision, empowered to give a stay of construction of a building for any violation of the provisions of these Regulations or the Master Plan/Zonal Development Plan or violation of the conditions of the building permission. If a stay is given by the Local Council, a copy of the stay order shall immediately be forwarded to the Aizawl Municipal Council which may confirm or cancel the stay after necessary enquiry and verification.
16 Completion Certificate :—
On completion of the building, the owner through the licensed engineer, registered architect etc., who has supervised the construction shall give completion certificate to the Aizawl Municipal Council in the form as given in Annexure E.
17 Offences and Penalties:—
Contravention of any of these regulations shall be dealt with as per the provisions of Sections 137, 374 and 386 of the Act’.
4Application for building/demolition permission:—
(1) Every person, including Central and State Government Departments and Semi-Government Departments/ Organisations excluding the Defence Ministry, who intends to erect, re-erect or make material/structural alterations (except internal alterations which do not affect the safety of the building) shall obtain a building permit by giving an application to the Aizawl Municipal Council in the prescribed form given in Annexure A to be purchased from the office of the Aizawl Municipal Council. The application shall be accompanied by the prescribed fees and three copies each of the documents mentioned in regulations 5(1) to 5(4) below. One copy each of these documents shall be returned to the applicant after issue of permission or refusal.
(2) In the case of proposal for demolition of any building, application may be submitted to the Aizawl Municipal Council on plain paper. The application shall contain proof of ownership, reason for the proposed demolition, location of the building, the date of the proposed demolition, the possible danger which the proposed demolition is likely to cause to the adjoining areas, if any, the over-all effect of the demolition on the locality, and No Objection Certificate (NOC) from the Local Council within whose jurisdiction the building is situated and other relevant information.
(3) In regard to vertical extension of a building, for erection/ construction of mumty, overhead water tank, greenhouse or other building services within the prescribed set backs, no permission is required if the height of the proposed erection/ construction is up to a maximum of 3 metres.”
(4) In the case of horizontal extension of a building, for addition/ extension of building/building services up to a maximum of 1.82m (6 ft.) between two adjacent columns within the prescribed set backs, application may be made on plain paper enclosing NOC from the concerned Local Council and an attested copy of land lease;
Provided that, if the proposed extension is likely to affect the structural safety of the building, the Aizawl Municipal Council shall have the power to require submission of application for building permission in the usual/prescribed manner or demand a certificate of structural safety.
Provided that in case of emergency when a building is required to be immediately demolished or dismantled due to landslide etc., the Local Council concerned may give permission for demolition of the building with an intimation to the Aizawl Municipal Council.
Provided further that no permission for demolition of a building shall be necessary in case of ordinary buildings except those situated along the motorable (black top) road.
5Information accompanying application for building permission:—
(1) In the case of ordinary building, the following information shall accompany the application for building permission:
(i) Ownership Title.
(ii) NOC from the concerned Local Council.
(iii) A certificate of structural soundness of the existing building in case of proposed addition.
(iv) Receipt of Latest Property Tax paid.
(2) In the case of semi-permanent building, the following information shall accompany application for building permission:
(i) Ownership Title;
(ii) NOC from the concerned Local Council.
(iii) Sketch plan and undertaking of structural safety prepared by Aizawl Municipal Council and Technical License Holder registered under AMC.
(iv) A certificate of structural soundness of existing building in case of proposed addition.
(v) Receipt of Latest Property Tax paid.
(3) In the case of concrete building, the following information shall accompany the application for building permission:
(i) Site Plan
(ii) Ownership title;
(iii) Building Plans;
(iv) NOC from the concerned Local Council;
(v) Structural drawing, and
(vi) Specifications.
(vii) A certificate of structural soundness of the existing building in case of proposed addition.
(viii) Receipt of Latest Property Tax paid.
(ix) NOC shall be obtained from the Local Fire Station for building above 15m.
Provided that in the case of building up to G+2 or 10 metres in height, (v) and (vi) above shall not be necessary if an undertaking of structural safety by Design Cell, Aizawl Municipal Council or by a competent technical person registered under Aizawl Municipal Council is enclosed with the application.
Provided that if the applicant and the LSC holder is not same, then NOC from the LSC holder countersigned by concerned Local Council shall be enclosed. In case, if the LSC holder is a deceased then Heirship Certificate shall be enclosed.
(4) If a Local Council refuses to issue No Objection Certificate to any person for building construction as indicated in regulations 5(1) to 5(3) above, and if such person is aggrieved by such refusal, he may approach the Aizawl Municipal Council by submitting an application on plain paper. On receipt of such application, the Aizawl Municipal Council shall ascertain from the concerned Local Council the reason or reasons for refusing the No Objection Certificate and make necessary investigation. Thereafter, the Aizawl Municipal Council shall take a decision as to whether or not construction of building is permissible.
(5) Site Plan shall be drawn to scales as shown below :
Sl.No.
Size of Plot (in sq.m)
Scale
1
Up to 150
1:50, 1:75, 1:100
2
From 151 to 250
1:100, 1:150, 1:200
3
From 251 to 500
1:200, 1:250, 1:300
4
Above 500
1:300, 1:350, 1:400, 1:500
and shall show :-
(i) boundaries of plot with dimensions;
(ii) position of the plot in relation to the neighbouring streets;
(iii) position of the proposed building in relation to north direction of the site;
(iv) plot area, coverage and F.A.R;
(v) sewerage and surface drains, position and sizes of septic tank and soak pit;
(vi) set backs of the building;
(vii) all existing structures on the plot, and
(viii) any other particular as may be prescribed by the Aizawl Municipal Council;
(6) Building plans accompanying the application shall be drawn to a scales of 1:50, 1:75, 1:100, 1:125 or 1:150. In case of exceptionally large buildings, a key plan to a scale of 1:200 shall also accompany the drawings. The Building Plans shall :
(i) include floor plans of all floors indicating the use of each floor of the building;
(ii) indicate height of the building and parapet;
(iii) give dimensions of the projected portions;
(iv) include a roof plan indicating drainage and roof slope in case of building proposal having pitch roof(s);
(v) specify the total floor area of the building;
(vi) include one elevation and sectional elevation in longitudinal directions indicating staircases, fire escape, lift well etc., and ground profile;
(vii provide for parking space, where necessary;
(viii) include site development and permanent structures like retaining wall, surface drain, approach road, steps etc., pertaining to the building, and
(ix) include provision for a suitable rain water harvesting facility.
(7) Specifications:- General specifications shall indicate the types and grades of materials to be used.
(8) Structural Drawings:- The structural drawings shall be prepared by a competent engineer/structural engineer as per the relevant provisions of the Indian Standard Code of Practice as given in ANNEXURE - F.
(9) Ownership Title:- An attested copy of land settlement certificate (LSC) or house pass or sale/lease deed shall also accompany the application.
(10) Colour Code:- The plans accompanying the applications shall have the colour scheme as specified in the Table given below and such colour scheme shall be indicated it in the legend of the plan.
Colouring Notation for Building Work
Sl.No.
Item
Notational Colouring
1
Plot lines
Thick black continuous line
2
Proposed Work
Red continuous lines
3
a) Existing Work(to be demolised)
Green dash-dot line
b) Existing Work(to be retained)
Green continuous line
4
Drainage & Sewerage Work
Blue continuous line
(11) Planning, Designing and Supervision of Building Works and signing of plans: - Every building work for which permission is sought under these Regulations, except building works relating to ordinary buildings, shall be planned, designed and supervised by licensed/registered technical personnel. All plans and drawing shall be duly signed by the applicant and by the licensed/registered technical person who has planned and designed the same.
The technical person/group/firm who signs the plans and drawings shall be responsible for supervision of the work till its completion.
(12) Qualifications and Competence of Technical Personnel:- The qualifications and competence of the technical personnel and licence fees shall be as given in Annexure B.
(13) A fine ranging from rupees one thousand to rupees five thousand may be imposed on a technical person by any person authorized by the Aizawl Municipal Council on this behalf for any of the following reasons:
(i) failure to supervise construction of a building in respect of which he signs the plans and drawings;
(ii) failure to give completion certificate in the form as prescribed under Regulation 12 read with Annexure D;
(iii) failure to report deviation from the sanctioned plan as required under Regulation 13;
(iv) failure to give commencement certificate in the form as prescribed under Regulation 16 read with Annexure E;
(v) preparation, on more than two occasions, of plans and drawings of a project which are not in conformity with the requirements of the Regulations, and
(vi) Failure to comply with any of the Duties & Responsibilities of Technical persons as stated in ANNEXURE B- 1.
Provided that the technical person concerned shall be given a reasonable opportunity to explain why such fine shall not be imposed on him/her.
(16) Every technical person, including a Group or Firm except Architects registered under Council of Architecture (COA), shall make a security deposit with the Aizawl Municipal Council as follows:
(a) Group/Firm 30,000.00
(b) Structural Engineer 15,000.00
(c) Engineer 10,000.00
(d) Town Planner 10,000.00
(e) Supervisor 5,000.00
However, any of the enlisted Architect under Aizawl Municipal Council found to contravene Regulation 5(13) of Aizawl Municipal Council Building Regulation shall be informed to the Council of Architecture (COA) for cancellation/suspension of his/her registration.
Technical person or Group/Firm from outside the State of Mizoram/Non Tribal shall possess valid Inner Line Permit (ILP) with atleast 2 years validity and other necessary documents which includes valid registration under AMC, work permit from the concerned Department etc. in order to provide professional expertise within the Aizawl Municipal Council Area. In addition , Technical person or Group/Firm from outside the State of Mizoram/Non Tribal shall pay the double of the entire License fee and security.
The security deposit, or the balance thereof after deduction of fine, if any, shall be reimbursed to the technical person concerned at the expiry of his/her license/registration.
(17) Duties and responsibilities of technical personnel and applicant/owner: - The duties and responsibilities of technical personnel and the applicant/owner shall be as in ANNEXURE B-I.
Submission of Application and Payment of Fees:— Application in the prescribed form and complete in all respects shall be submitted to the office of the Aizawl Municipal Council. If the application is found to be in order and complete in all respects, the amount of fee payable shall be calculated under Regulation 20 of the Aizawl Municipal Council Building Regulations, 2012 and the same shall be paid to the Aizawl Municipal Council by the applicant for which two copies of receipt shall be issued. The applicant shall enclose the duplicate copy of the receipt with his application which is to be submitted to the Aizawl Municipal Council. If the application is found to be not in order, the same shall be returned to the applicant.
7Grant of Building Permission :—
(a) The Aizawl Municipal Council may grant permission or may grant permission after modification(s), based on conformity or otherwise with these regulations and shall communicate its decision to the applicant. Grant of permission shall be communicated to the applicant in the prescribed form given in ANNEXURE C. A copy thereof shall be endorsed to the concerned Local Council and the concerned technical person.
Provided that if, within 30 days of receipt of the application complete in all respects along with a duplicate copy of receipt for payment of the prescribed fee, the Aizawl Municipal Council fails to intimate to the applicant its refusal or sanction or any intimation, the application with its plans and specifications shall be deemed to have been sanctioned provided the fact is brought to the notice of the Aizawl Municipal Council in writing by the applicant within seven days.
(b) Refusal of Building Permission: If permission is to be refused, the applicant shall be given an opportunity to show cause why permission as sought for should not be refused in the form prescribed in ANNEXURE C-I. A copy thereof shall be endorsed to the concerned Local Council and the concerned technical person.
Provided that if the applicant did not complied to the show cause notice given within a specific period. The application shall be refused in the form prescribed in ANNEXURE C-II.
8 Duration of Validity of Building Permission : —
The building permission once accorded shall remain valid up to one year. Fees for extension every year, which may for a period up to one year, shall be one-fourth of the original fees paid earlier.
9 Withdrawal of Application : —
The applicant may withdraw his application at any time prior to sanction, and such withdrawal shall terminate all proceedings with respect to such application, but the fees paid shall not be refunded.
10 Cancellation of Permit : —
If, at any time after the issuance of the permit, if the Aizawl Municipal Council is satisfied that such permit was granted in consequence of any material misrepresentation or fraudulent statement contained in the application given or information furnished, the Aizawl Municipal Council has the right to cancel the permit and any work done or rendered shall be deemed to have been done without permission.
11 Suspension of Permit : —
Building permit granted under these Regulations shall be deemed to be suspended in case of resignation by the technical person who supervises the building work till new technical person is engaged and the Aizawl Municipal Council is informed of such engagement by the permit holder. Any work done during the period of suspension shall be treated as unauthorised construction.
12 Notice for commencement of building work :—
Before the commencement of the work the owner shall give notice to the Aizawl Municipal Council in the prescribed proforma given in Annexure D indicating the date on which he proposes to commence the work and the Aizawl Municipal Council shall inspect the work within fourteen days from the date on which the work is to commence as indicated in the proforma.
13 Deviation during building construction :—
For any deviation from the sanctioned plan during any stage of construction, permission of the Aizawl Municipal Council shall be obtained by the person who has obtained permission for building construction and if the construction is not according to the approved plan; action shall be taken as per the provisions of the Act. Any deviation from the sanctioned plan shall be immediately reported to the Aizawl Municipal Council by the technical person who supervises the work of building construction.
14 Inspection : —
The Aizawl Municipal Council shall carry out inspection of the construction works, from the receipt of commencement of work to the receipt of completion certificate, at various stages of construction to ascertain whether the work is proceeding as per the provisions of these Regulations and the sanctioned plan.
3Definitions :— For the purpose of these regulations,
(1) ‘Act’ means the Mizoram Municipalities Act, 2007 (Act No. 6 of 2007);
(2) ‘Advertising Sign’ means any surface or structure with characters, letters or illustrations applied thereto and displayed in any manner whatsoever out of doors for the purpose of advertising or to give information or to attract the public to any place, person, public performance, article or merchandise whatsoever, and which surface or structure is attached to or forms part of or is connected with any building, or is fixed to a tree or to the ground or to any pole, screen, fence or hoarding or displayed in space;
(3) ‘Alteration’ means a change from one occupancy to another, or a structural change or change of any component of the buildings;
(4) ‘Apartment’ means a building arranged/intended /designed for occupation by families independent of each other for the purpose of sale or lease to individual families;
(5) ‘Approved’ means approved by the Aizawl Municipal Council or any officer or person to whom appropriate power has been delegated by the Aizawl Municipal Council;
(6) ‘Applicant’ means every person who applies to the Aizawl Municipal Council for permission under these regulations;
(7) ‘Area’ in relation to a building means the superficies of a horizontal section thereof made at the plinth level inclusive of the external walls and of such portions of the party walls as belong to the building;
(8) ‘Balcony’ means a horizontal projection of a building including hand-rail, balustrade or a parapet to serve as a passage or a sitting out place;
(9) ‘Basement or Cellar’ means the lower storey of building below or partly below ground level;
(10) ‘Building’ means any structure constructed for whatsoever purpose and of whatsoever materials and every part thereof, whether used as human habitation or not and includes foundations, plinths, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms, verandah, balcony, cornice or projection, part of a building or anything affixed thereto or any wall enclosing or intended to enclose any land or space and signs and outdoor display structures, monuments, memorials or any contrivance of permanent nature/stability built under or over ground.
For the purposes of these regulations, buildings are divided into three types, namely,
a) ‘Multi-storied building’ means a building having a height of 15 metres or more.
Coverage = Plinth area of ground floor x 100 Plot area
(15) ‘Covered Area’ means the ground area immediately above the plinth level covered by the building but does not include the space covered by -
(i) garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round tree, tank, fountain and bench;
(ii) drainage, culvert, conduit, catch-pit, gully-pit, chamber, gutter and the like, and
(iii) compound wall, gate, slide/swing door, canopy, and areas covered by chajja or similar projections and staircases which are uncovered and open at least on three sides and also open to the sky;
(16) ‘Density’ means concentration of population expressed in terms of the number of persons per hectares in a particular area;
(17) ‘Drain’ means a conduit or channel for the carriage of storm water, sewage or other used water and includes all fittings and equipments, such as manhole, inspection chambers, traps, gullies and floor traps used for the drainage of a building. It also includes open channel used for conveying surface water;
(18) ‘Demolition’ means total dismantling of an existing building;
(19) ‘Drainage’ means a system constructed for the purpose of removal of waste and surface water;
(20) ‘Dwelling’ means a building or a portion thereof which is designed or used wholly or principally for residential purposes for a family;
(21) ‘Exit’ means a passage, channel or means of egress from any building or floor area to a street or open space;
(22) ‘External Wall’ means an outer wall of a building not being a party wall even though adjoining to a wall of another building and also means a wall abutting on an interior open space of any building;
(23) ‘Floor’ means the lower surface in a storey on which one generally walks in a building, and does not include a mezzanine floor. The floor at ground level or immediately above the ground level shall be called the ‘ground floor’ and the floor above it shall be termed as the ‘first floor’ with the next higher floor being termed as the ‘second floor’ and so on;
(24) ‘Floor Area Ratio’ (F.A.R.) means the quotient obtained by dividing the total covered area (plinth area) of all floors by the area of a plot, i.e.,
F.A.R. = Total covered area of all floors Plot area
(25) ‘Footing’ means a foundation unit constructed in brick-work, stone masonry or concrete under the base of a wall or column for the purpose of distributing the load over a larger area;
(41) ‘Party Wall’ includes
(i) a wall forming part of a building and being used and constructed to be used in any part of the height or length of such wall for separation of adjoining buildings belonging to different owners or constructed or adopted to be occupied by different persons, and
(ii) a wall forming part of a building and standing in any part of the length of such wall, to a greater extent than the projection of the footing on one side or ground of different owners;
(42) ‘Permission or Permit’ means a valid permission or authorisation in writing by the Aizawl Municipal Council or any person authorised by it in this behalf to carry out development or work regulated by these regulations;
(43) ‘Plinth’ means the portion of a structure between the level of the ground and the floor immediately above the ground;
(44) ‘Plinth Area’ means the built-up covered area measured at the floor level of the ground floor or of any storey;
(45) ‘Plot or Site’ means a parcel or piece of land enclosed by definite boundaries;
(46) ‘Road/Street’ means any highway, street, land, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether a thorough-fare or over which the public have a right of passage or access or have passed and have access uninterruptedly for a specified period, whether existing or proposed in any scheme and includes all bends, channels, ditches, storm water drains, culverts, sidewalks, traffic islands, roadside trees and hedges, retaining walls, fences, barriers and railings within the street lines;
(47) ‘Room Height’ means the vertical distance measured from the finished floor surface to the finished ceiling surface;
(48) ‘Sanctioned Plan’ means a set of plans and specifications submitted under these regulations in connection with a building and duly approved and sanctioned by the Aizawl Municipal Council;
(49) ‘Set Back’ means the open space from the proposed building to the plot boundaries beyond which nothing can be constructed towards the boundaries;
(50) ‘Spiral Staircase’ means a staircase having treads forming continuous winding curve round a central point or axis provided in the open/covered/semi-covered space;
(a) Stair cover or Mumty means a structure with a roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not used for human habitation.
(51) ‘Storey’ means the portion of building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it.
b) ‘Special building’ means a building such as educational, assembly, institutional, industrial, storage, hazardous and mixed occupancies with any of the aforesaid occupancies having covered area more than 500 sq. metres.
(i) ‘Ordinary building’ Ordinary building means a building constructed with first class wooden posts, RCC posts up to the skirting level of the ground floor, wooden plank floor, bamboo or tile or sheet wall and thatched or GCI (galvanized corrugated iron) sheet roof covering;
(ii) ‘Semi-Permanent (Semi-Pucca) Building’ Semi-permanent (semi-pucca) building means a building constructed with RCC (reinforced cement concrete) column footings, RCC columns and RCC beams of pre-designed dimensions and specifications upto a height not exceeding 7.5 metres having timber flooring, brick/ concrete block masonry wall up to skirting level, AC sheet or bamboo walling above skirting, timber roof truss with G.C.I. sheet roofing;
(iii) ‘Permanent Building’ Permanent building means-
(a) a building constructed with RCC foundation, column, beam, floor, roof and brick walling, or
(b) a building constructed with steel structural members.
(11) ‘Building, Height’ of’ means —
(i) in the case of flat roofs or hip type roofs, the vertical distance from the ground floor to the highest terrace level;
(ii) in case of pitched roofs, the vertical distance from the ground floor up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof;
(iii) in case of multi-storeyed buildings constructed on a slope having multiple ground floor levels, the vertical distance between any ground floor level and the corresponding highest point of the building directly above it.
(iv) Architectural features serving no other function except that of decoration shall be excluded for the purpose of taking heights. The height of the building shall be taken up to the terrace level for the purpose of fire safety requirements.
(12) ‘Canopy’ means a projection from the face of the wall over an entry to the building at the lintel or slab level provided that -
(i) it shall not project over the set back line;
(ii) it shall not be lower than 2.3 metres when measured from ground, and
(iii) there shall be no structure on it and the top shall remain open to the sky.
(13) ‘Chajja’ means a projection or horizontal structure overhang usually provided over opening of external walls to provide protection from sun and rain or from architectural consideration;
(14) ‘Coverage’ means the quotient obtained in terms of percentage by dividing the plinth areas of ground floor by plot area, i.e.,
(26) ‘Foundation’ means that part of the structure which is in direct contact with the ground and which transmits load over it;
(27) ‘Garage’ means a building or portion thereof designed and used for parking of vehicles;
(28) ‘Ground Level’ means the level of the natural ground surface or the finished surface after leveling from where erection of the building starts;
(29) ‘Habitable Room’ means a room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is used for a living room, but not including bathrooms, water closet compartment, laundries, corridors, cellars, attics and spaces that are not used frequently;
(30) ‘Licensed Structural Engineer/ Engineer/ Architect/ TownPlanner/ Supervisor/ Group or Firm’ means a qualified Structural Engineer etc., who has been given licence or recognised by the Aizawl Municipal Council. An architect who is registered as an architect by the Council of Architecture under the Architects Act, 1972 (20 of 1972) may be deemed to be licensed by the Aizawl Municipal Council by virtue of his/her registration with the Council of Architecture provided he/she enrolls himself/herself with the Aizawl Municipal Council.
(31) ‘Ledge’ means a shelf-like projection, supported in any manner whatsoever, except by means of vertical supports within a room itself but not having projection wider than one metre;
(32) ‘Lift’ means a mechanically guided car, platform for transport of persons and materials between two or more levels in a vertical or substantially vertical direction;
(33) ‘Loft’ means an intermediate floor between two floors or a residual space in a pitched roof, above normal floor level with a maximum height of 1.5 metre and which is used for storage purposes;
(34) ‘Master Plan’ means the Master Plan for Aizawl as approved by the Government under the Act which shall extend to the Aizawl Municipal Council area;
(35) ‘Mezzanine Floor’ means an intermediate floor between two floors above ground level;
(36) ‘Open Space’ means an area forming an integral part of the plot, left open to the sky;
(37) ‘Owner’ means a person or group of persons, a company, trust, institute, registered body, State or Central Government Departments and offices under them in whose name is vested the ownership dominion or title of the property and includes a receiver, executor or administrator, or a person who is legally empowered to construct or execute work on a building unit or structure or a manager appointed by any court of competent jurisdiction to have the charge of or to exercise the rights of the owner.
(38) (1) ‘Occupancy’ means the function or use of the building;
(2) (a) Residential A: These include any building in which sleeping accommodation is provided for normal residential purposes not exceeding 150 sq.m floor area.
(b) Residential B: These include one or two or multi-family dwellings with residential accommodation exceeding 150 sq.m floor area.
(c) Special Residentials: These include all lodging houses, dormitories, hostels and hotels with residential accommodation.
(d) Educational Buildings: These include any building or part thereof used for school, college, primary and nursery school, education or research purpose and recreation not covered under Institutional.
(e) Mercantile (Commercial) Buildings: These include any building or part of the building which is used for display or sale of merchandise such as shops, stores, markets etc., either whole-sale or retail, banking and financial institutions, private business houses and professional establishments of doctors, dentists, tailors etc. beauty parlour, barber shops, new stands, milk booth, lunch counters and restaurants.
(f) Institutional (Medical) Buildings: These include any building or part thereof, which is used for purposes such as medical or other treatment or care of persons suffering from physical or mental illness, diseases or infirmity. Buildings and structures under this use shall include hospitals, clinics, homes for the aged and infirm, convalescent homes and orphanages, mental hospitals etc.
(g) Government Buildings: These include any building or part of a building which is used for the transaction of Government business, for records keeping, accounts and similar purposes. Local Government and Semi-Government offices, court houses, public utility buildings including slaughter houses, jails and prisons etc., will be covered by this use.
Assembly Buildings: These include any building or part of a building where group of people (exceeding 100) congregate or gather for amusement, recreation, social, religious, patriotic, civil, travel and other purposes; for example, theatres, cinemas, assembly halls for educational, dramatic or theatrical presentation, auditorium, exhibition halls, art galleries, museums, libraries.
(i) Industrial Buildings: These include any building or part of building or structure in which products or materials of all kinds and properties are fabricated, assembled or processed e.g., workshops, assembly plants, laboratories, laundries, dairies, saw mills, power plants etc.
(j) Storage Buildings: These include any building or part thereof used primarily for the storage or shelter of goods, wares or merchandise and include buildings used as warehouse, cold storage, freight depot, transit shed, store house, public garage, hanger, truck terminal, grain elevator, barn and stables.
(k) Hazardous Buildings: These include any building or part of a building which is used for the storage, handling, manufacture or processing of highly combustible, explosive, poisonous, irritant, toxic or noxious materials or products or materials producing dust.
(39) ‘Parapet’ means a low wall or railing built along the edge of a floor or a roof;
(40) ‘Parking Space’ means an enclosed or unenclosed covered or open area sufficient in size to park vehicles. Parking spaces shall be served by a driveway connecting them with a street or alley and permitting ingress and egress of vehicles;
(52) ‘To make Material Alterations’ means to make any modification in any existing building by way of addition or alteration or any other change which may affect the appearance, occupancy and safety of the building.
(53) ‘Total Floor Area’ means the area of all floors of a building including habitable rooms, attic, basement and mezzanine floor;
(54) ‘Travel Distance’ means the distance an occupant has to travel to reach the exit from the remotest point;
(55) ‘Unauthorised Construction’ means the erection or re-erection, addition or alteration which is not approved or sanctioned by the Aizawl Municipal Council;
(56) ‘Verandah’ means a covered/semi-covered/open area with at least one side open to the outside and the floor of which is resting on the ground;
(57) ‘Local Council’ means a Local Council constituted under sub-section (3) of section 23 of the Mizoram Municipalities, Act 2007 (as amended in 2009);
(58) ‘Water Closet’ or ‘W.C.’ means a privy with an arrangement for flushing/cleaning the pan with water;
(59) ‘Wheel Chair’ means a device used by a disabled person for mobility;
(60) Words and expressions used but not defined in these regulations shall have the same meaning and sense as in the Mizoram Municipalities Act, 2007 (as amended in 2009) and the Rules made thereunder.