IS 1893-2002 Criteria for Earthquake Resistant Design of Structures (Fifth Revision)
-
IS 13920-1993 : Ductile Detailing of Reinforced Concrete Structures subjected to Seismic Forces Code of Practice.
-
IS 4326-1993 : Earthquake Resistant Design and Construction of Buildings-Code of Practice (Second Revision)
-
IS 13828-1993 : Improving Earthquake Resistance of Low Strength Masonry Buildings- Guidelines.
-
IS 13827-1993 : Improving Earthquake Resistance of Earthen Buildings-Guidelines
-
IS 13935-1993 : Repair and Seismic Strengthening of Buildings-Guidelines.
For Protection of Landslide Hazard
-
IS 14458 (Part 1) 1998 Guidelines for Retaining Wall for Hill Area: Part1: Selection of Type of Wall.
-
IS 14458 (Part 2) 1997 Guidelines for Retaining Wall for Hill Area: Part 2 Design of Retaining/ Breast Walls.
-
IS 14458 (Part 3) 1998 Guidelines for Retaining Wall for Hill Area: Part 3 Construction of Dry Stone Walls.
-
IS 14496 (Part 2) 1998 Guidelines for Preparation of Landslide-Hazard Zonation Maps in Mountainous Terrains: Part 2 Macro-Zonation.
NEXURE -
(Regulation 39 of the Aizawl Municipal Council Building Regulations, 2012) REQUIREMENTS OF SANITARY FITTINGS IN PUBLIC BUILDINGS
(a)Requirements of sanitary fittings for Office buildings:
| S l .N o. | F itm e nts | For Ma les | For Fem a les |
|---|---|---|---|
| 1 | Water Closet | 1 for every 25 persons or part the reof | 1 for every 1 5 persons part the reof exceed ing 1 0 |
| 2 | Abl ution Ta ps | 1 i n each Water Closet | 1 in each Water Closet |
| 3 | U rina ls | N il u pto 6 pe rsons 1 for 7 - 20 persons 2 for 2 1 - 45 persons 3 for 46- 70 persons 4 for 7 1 - 1 00 persons from 1 0 1 -200 persons added at the rate of 3% above 200 persons added at the rate of 2 .5% | |
| 4 | Wash Basin | 1 for every 25 persons or part the reof the reof exceed ing 1 0 . | 1 for every 25 persons or part |
AIZAWL MUNICIPAL COUNCIL BUILDING REGULATIONS,2012
(b)Requirements of Sanitary fittings in Shops and Commercial Offices.
| S l .N o. | F itm e nts | For Person ne l |
|---|---|---|
| 1 . | Water closet | One for eve ry 25 persons or part thereof exceed ing 1 5 (inclu d ing employees and customers) . For fema le person nel 1 for every 1 5 persons or part the reof exceed ing 1 0 . |
| 2 . | Drin king water fou ntai n | One for every 1 00 pe rsons with a mi n imu m of one on each floor. |
| 3 . | Wash basin | One for eve ry 25 persons or part thereof. |
| 4 . | U ri na l | N il u p to 6 pe rsons One for 7 - 20 persons 2 for 2 1 - 45 persons 3 for 46 - 70 persons 4 for 7 1 - 1 00 persons For 1 0 1 to 200 persons, add @ 3% For over 200 persons, add @ 2% |
| 5 . | Clea ne r's Si n k | One per floor min im u m , preferable in or adjacent to san itary rooms . |
:1 may be assum persons in the premises for a time interval of one hour during the peak period. For male-female calculation a ratio Number of customers for the purpose of the above calculation shall be the average number of Note :
AIZAWL MUNICIPAL COUNCIL BUILDING REGULATIONS,2012
(d)Requirements of Sanitary fittings for Special Residentials :
| Sl.No. | Fitments | For Residential Public & Staff | For Public Rooms | For Non-Residential Staff | ||
| For Male | For Female | For Male | For Female | |||
| 1. | Water Closet | One per 8 persons omitting occupants of the room with attached water closet. Minimum of 2 if both sexes are lodged | One per 100 persons upto 400 persons; for over 400 add @ 1 per 250 persons or part therof. | 2 for 100 persons upto 200 persons; over 200 add @ 1 per 100 persons | 1 for 1-15 persons2 for 16-35 persons3 for 36-65 persons4 for 66-100 persons | 1 for 1-12 persons2 for 13-25 persons3 for 26-40 persons4 for 41-57 persons |
| 2. | Ablution | One in each water closet | One in each water closet | One in each water closet | One in each water closet | One in each water closet |
| 1 water tap with drainage arrangements shall be provided for every 50 persons or part therof in the vicinity of water closet and urinals | ||||||
| 3. | Urinals | One for 50 persons or part thereof | Nil upto 6 persons1 for 7-20 persons2 for 21-45 persons3 for 46-70 persons4 for 71-100 persons | |||
| 4. | Wash Basins | One per 10 persons omitting the wash basins installed in the room suits | One per water closet and urinal provided | One per water closet provided | 1 for 1-15 persons2 for 16-35 persons3 for 36-65 persons4 for 66-100 persons5 for 58-77 persons | 1 for 1-12 persons2 for 13-25 persons3 for 26-40 persons4 for 41-57 persons5 for 58-100 persons |
| 5. | Baths | One per 10 persons omitting occupants of the room with bath in suits | ||||
| 6. | Stop sinks | One per 30 bed rooms(one per floor min.) | ||||
| 7. | Kitchen sinks | One in each Kitchen | One in each Kitchen | One in each Kitchen | One in each Kitchen | One in each Kitchen |
Requirements of Sanitary fittings for Educational Occupancy
| Sl.No. | Fitments | Nursery School | Boarding Institution | Boarding Institution | Other Educational Institution | Other Educational Institution |
| 1. | Water Closet | One per 15 pupils and part thereof | For BoysOne per 8 pupils and part thereof | For GirlsOne per 6 pupils and part thereof | For BoysOne/40 pupils and part | For GirlsOne/25 pupils and part |
| 2. | Ablution Taps | One in each water closet | One in each water closet | One in each water closet | One in each water closet | One in each water closet |
| 2. | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals |
| 3. | Urinals | One per every 25 pupils or part thereof | One per every 20 pupils or part thereof | |||
| 4. | Wash Basins | One per every 15 pupils or part thereof | One per every 8 pupils or part thereof | One per every 6 pupils or part thereof | One per every 40 pupils or part thereof | One per every 40 pupils or part thereof |
| 5. | Basins | One bath sink per 40 pupils or part thereof | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | ||
| 6. | Drinking Water fountains | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof |
| 7. | Cleaner's sink | One per floor (minimum) | One per floor (minimum) | One per floor (minimum) | One per floor |
Requirements of Sanitary fittings for Institutional Medical Occupancy (Staff Quarters and Hostels)
| S l . N o . | F i t m e n ts | D octo r' s D o r F o r M a le Staff | m i to r i e s F o r Fe m a l e Staff | N u rse H ote l s |
|---|---|---|---|---|
| 1 . | Water C loset | On e fo r 4 perso ns | On e fo r 4 perso ns | On e for 4 perso ns an d pa rt th ereof |
| 2 . | Abl utio n Taps | O ne i n each wate r closet | O ne i n each wate r closet | O ne i n each wate r closet |
| 3 . | Wash Basi n s | O ne fo r every 8 person s or pa rt th ereof | O ne fo r every 8 person s or pa rt th ereof | O ne fo r every 8 person s or pa rt th ereof |
| 4 . | Bath s (with s h owe r) | O ne fo r every 4 person s o r pa rt th ereof | O ne fo r every 4 person s o r pa rt th ereof | O n e fo r eve ry 4-6 perso ns o r pa rt th ereof |
| 5 . | C l ea n e r' s s i n k | On e pe r fl oo r (m i n i m u m ) | On e pe r fl oo r (m i n i m u m ) | On e pe r fl oo r (m i n i m u m ) |
Public Business Occupancies and Offices Requirements of Sanitary fittings for Governmental and
| Sl.No. | Fitments | Other Educational Institution | |
| For Males Personnel | For Females Personnel | ||
| 1. | Water Closet | One for every 25 persons or part thereof | One for every 15 persons or part thereof |
| 2. | Ablution Taps | One in each water closet | One in each water closet |
| 3. | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals. | ||
| Urinals | Nil upto 6 persons1 for 7-20 persons2 for 21-45 persons3 for 46-70 persons4 for 71-100 personsfrom 101 to 200 persons add @ of 3%; for over 200 persons add @ of 2.5% | ||
| 4. | Wash Basins | One for every 25 persons or part thereof | |
| 5. | Drinking water fountains | One for 100 persons with a minimum on each floor | |
| 6. | Baths | Preferably one on each floor | |
| 7. | Cleaner's sink | One per floor (minimum) preferably in or adjacent to sanitary rooms | |
ma, Theatres, Auditori Requirements of Sanitary fittings for Assembly Occupancy Buildings
| SI.No. | Fitments | For Public | For Staff | ||
| Males | Females | Males | Females | ||
| 1. | Water Closet | One per 100 persons upto 400 persons. For over 400 persons, add @ of 1 per 250 persons or part thereof | Two per 100 persons upto 200 persons. For over 200 persons, add @ of 1 per 100 persons or part thereof | One for every 1-15 persons Two for 16-35 persons | One for every 1-12 persons Two for 13-25 persons |
| 2. | Ablution Taps | One in each water closet | One in each water closet | One in each water closet | One in each water closet |
| One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals. | |||||
| 3. | Urinals | One for every persons or part thereof | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons | ||
| 4. | Wash Basins | One for every 200 persons or part thereof | One for every 200 persons or part thereof | 1 for 1-15 persons 2 for 16-35 persons | 1 for 1-12 persons 2 for 13-25 persons |
Note : It may be assumed that two-third of the number are males and one-third females.
Requirements of Sanitary fittings for Assembly Buildings (Art Galleries, Libraries and Museums).
| SI.No. | Fitments | For Public | For Staff | ||
| Males | Females | Males | Females | ||
| 1. | Water Closet | One per 200 persons upto 450 persons. For over 400 persons, add @ of 1 per 250 persons or part thereof | One per 100 persons upto 200 persons. For over 200 persons, add @ of 1 per 150 persons or part thereof | One for every 1-15 persons Two for 16-35 persons | One for every 1-12persons Two for 13-25 persons |
| 2. | Aublution Taps | One in each water closet | One in each water closet | One in each water closet | One in each water |
| One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinals | |||||
| 3. | Urinals | One for every 50 persons | Nil upto 6 persons1 for 7-20 persons2 for 21-45 persons | ||
| 4. | Wash Basins | One for every 200 persons or part thereof. For over 200 persons, add @ of 1 per 250 persons or part thereof | One to every 200 persons or part thereof. For over 200 persons, add @ of 1 per 150 persons or part thereof | 1 for 1-15 persons2 for 16-35 persons | 1 for 1-12 persons2 for 13-25 persons |
| 5. | Cleaner's sink | 1 per floor minimum | |||
Note : It may be assumed that two-third of the number are males and one-third females
| Sl.No. | Fitments | For Public | For Staff | ||
| Males | Females | Males | Females | ||
| 1. | WaterCloset | One for 50 seats upto 200 seats. For over 400 seats, add @ of 1 per 100 seats of part thereof | One for 50 seats upto 200 seats. For over 200 seats, add @ of 1 per 100 seats or part thereof | One for every 1-15 personsTwo for 16-35 personsThree for every 36-65Four for every 66-100 persons | 1 for 1-12 persons2 for 13-25 persons3 for 26-40 persons4 for 41-57 persons5 for 58-77 persons6 for 78-100 persons |
| 2. | AblutionTaps | One in each water closet | One in each water closet | One in each water closet | One in each water closet |
| One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals | |||||
| 3. | Urinals | One per 50 seats | Nil upto 6 persons1 for 7-20 persons2 for 21-45 persons3 for 46-70 persons4 for 71-100 persons | ||
| 4. | Wash Basins | One for every water closet | |||
| 5. | Kitchen sinks and dish washer | One in each Kitchen | |||
| 6. | Stop or service sink | One in the Restaurant | |||
Note : It may be assumed that two-third of the number are males and one-third females
| SI.No. | Fitments | Other Educational Institution | |
| For Males Personnel | For Females Personnel | ||
| 1. | Water Closet | 1 for 1-15 persons2 for 16-35 persons3 for 36-65 persons4 for 66-100 personsFrom 101 to 200 persons add @ of 3%;from over 200 persons add @ of 2.5% | 1 for 1-12 persons2 for 16-25 persons3 for 26-45 persons4 for 41-57 persons5 for 58-77 persons6 for 78-100 persons |
| 2. | Ablution Taps | One in each water closet | From 101 to 200 persons add @ of 5%;From over 200 persons add @ of 4%One in each water closet |
| 3. | One water tap with drainage arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closet and urinals. | ||
| Urinals | Nil upto 6 persons1 for 7-20 persons2 for 21-45 persons3 for 46-70 persons4 for 71-100 personsFrom 101 to 200 persons add @ of 3%;For over 200 persons add @ of 2.5% | ||
| 4. | Wash taps | One for every 25 persons or part thereof | One for every 25 persons or part thereof |
| 5. | Drinking water fountains | One for 100 persons with a minimum of one in each floor | |
| 6. | Baths preferably showers | As required for particular trades or occupation | |
AIZAWL MUNICIPAL COUNCIL BUILDING REGULATIONS,2012