Up to 235 sqm. of plot and building ht. not exceeding 10m. -70%
Up to 1000 sqm. of plot and building ht. up to 16.4m. -60%
Above 1000 sqm. of plot area or building ht. of more than 16.4m. -50%
For commercial uses ground coverage is 50% of the plot area.
38. General Conditions for Setback
38.1 In case of more than one block of buildings are constructed on the same the plot, the minimum distance between the two blocks shall be 6m. (Six meter) or 1.5 times side setback required for the taller block whichever is higher.
Basement can be constructed in this open area in between the buildings, top of which may be used as passage and garden and if used
X
38.2
for vehicular passage the roof slab should have sufficient strength for the fire of engine 45 tones.
The minimum setbacks/open spaces for other occupancies shall be as below;
38.2.1 Educational buildings - In case of educational buildings the open spaces around the building shall not be less than 6 meter. The front set back shall be not less than 9 m.
38.2.2 Institutional buildings - The open spaces around the building shall not be less than 6 m. The front setback shall be not less than of 9m.
38.2.3 Assembly buildings- The open space in front shall be not less than 12m and the other open spaces around the building shall not be less than 6m.
38.2.4 Malls and Multiplex- The front set back shall not be less than 12 m, the rear set back shall not be less than 7 m and the side set back shall not be less than 7m.
38.2.5 Commercial & Storage buildings - In case of plots with more than 1000 sqm. area, the open spaces around the building shall not be less than 6.0 m. The front setback shall be of 9m. In all other cases it shall be as per Table 10. and table 14
38.2.6 Industrial buildings - The setbacks shall be as per Table 12 and 13.
41.2.7 Hazardous occupancies -The open spaces around the building shall not be less than 9 m. The front set back shall be of 12m.
38.2.8 Slum Improvement- The setback norms shall not apply to slums taken up under an approved programme of the Government subject to the specific sanction of the Government.
38.2.9 IT/ITES Buildings-Abutting a means of access of 12 m or more the setback, height, number of floors and FAR shall be applicable as per commercial building in respect of corresponding road width.
38.3 The setbacks shall be calculated on the basis of highest provision of setback mentioned either in the above table or mentioned in these Bye Laws.
38.4 The setbacks are to be left after leaving the affected area of the plot/site, if any, for road widening.
SΔ ACD = SΔ COD + SΔ BDO
Where a site abuts more than one road, then the front setback should be towards the bigger road width or main approach road in case of equal widths. The side setbacks shall be as per the width of plot and rear set back as per the depth of plot.
38.5.1 Road junction corner plots shall have sufficient weaving angle. In no case it shall be less than the space arrived at by drawing a quadrant of a circle of 4.5m radius at the edge of the actual road lines leaving the width of pedestrian walks (foot path) and the plot boundaries shall be rounded of by drawing a quadrant of the circle of 2.7m radius at the edge of plot boundaries.
38.5.2 The height of the boundary wall shall be restricted to 0.75m for a length of 5m on the front and side of the intersections and the remaining height of 1.5m shall be made up of steel grill work.
38.6 For narrow plots having extent not more than 400 sqm. and where the length is 4 times of the width of the plot, the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10m. and minimum of 2m. in case of buildings of height up to 12 m. without exceeding overall permissible plinth area.
38.7 The master plan/development plan/zonal plan shall also specify a building line for various areas. The setbacks shall accordingly be changed without reducing the minimum required setbacks under these bye laws.
Chapter IVGeneral Requirements
30. Restriction on permission
Without prejudice to any other stipulation in these bye laws, no permission to construct a building on a site shall be granted:
30.1 In areas of natural waterways or drains, as detailed in the Development Plan, and drainage plan as modified from time to time;
30.2 If the use to which the site is proposed to be put does not conform to the use earmarked in the Development Plan/Master Plan/Zonal Development Plan;
30.3 If the building is to be constructed over or under a municipal drain, sewerage line, electrical line, water main, any other government or public land, or public utility services;
30.4 As Jharkhand is located in Seismic Zone II, III and IV if the Structural Plans are not prepared taking this into account.
30.5 In case of areas which get flooded, the Structural Plans are not prepared taking this into account.
31. Requirement of Site
31.1 No building shall be constructed on any site on any part of which there is deposited refuse, excreta or other offensive matter objectionable to the Authority. Until such refuse has been removed there from and the site has been prepared or left in a manner suitable for building purposes to the satisfaction of the Authority;
31.2 Wherever the dampness of a site or the nature of the soil renders such precautions necessary, the ground surface of the site between the walls of any building erected thereon shall be rendered damp-proof to the satisfaction of the Authority;
31.3 Any land, passage or other area within the cartilage of a building shall, if the Authority so requires, be effectively drained by surface water drains or other means;
31.4 If the foundation of the external wall along a Street is located at a distance less than one meters from the edge of the street or road margin including the drain;
The written approval of the Authority shall be obtained for connecting any sub-soil or surface water drain to a sewer;
omni: kgor 37.
[Signature]
32. Distance from Electric lines
No verandah, balcony or the like shall be allowed to be erected or re-erected or any additions or alterations made to a building, within the distances ‘quoted below between the building and any overhead electric supply line.
The minimum distance from the electric line shall be as per Table 5.
Table - 5: Minimum distance from electric line
Vertical distance in meters
Horizontal distance in meters
Low and medium voltage lines and service lines
2.5
2.5
High voltage lines up to and including 11,000 Volt
Not Permitted
3.7
High voltage lines above 11,000 volt and up to and including 33,000 Volt
Not Permitted
3.7
Extra high voltage line beyond 33,000 Volt
Not Permitted
3.7 (Plus 0.3 meters for every additional 33,000 volts or part thereof)
33. Plantation
33.1 In every building area, at least 5% of the land shall be covered by plantation (tree cover), but in case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover). Internal gardens within the building shall be encouraged.
34. Means of Access
34.1 Every plot shall abut on a public/private means of access like streets/roads of duly formed of width as specified in these byelaws or specified in the Master Plan/Development/Zonal Plan/Scheme.
The minimum width of the road/street required for access to a new building in an existing colony not developed by any authorized agency such as Regional Development Authority, Municipality, Housing Board, Co-operative societies, Government and Semi government organization shall be as per Table 6.
Table 6; Length of road limitation
Old Area
Sl. No.
Maximum Length of the road in Meter
Minimum width of road of street in Meter
(i)
(ii)
(iii)
1
Upto 50 meter
3.6 meter
2
Exceeding 50 meter and upto 100 meter
5.1 meter
3
Exceeding 100 up to 300 meter
6.6 meter
4
Exceeding 300 meter
7.5 meter
Note-On less than 6.1 m. wide roads the encroachment from both sides will be removed by measuring 3.05 m. from the centre line of the width of roads declared by or belonging to Road Construction Department Jharkhand, Municipal Authorities, Housing Board, Co-operative Societies, Government and Semi-Government Organizations In other cases
[Illegible Handwriting]
maximum 3.05 m. land from such revenue plot on either side will be taken into account to make it 6.1 m. wide road and the construction falling in between the said width of road will be removed as an encroachment.Similarly 1.80 m. and 2.55 m. land from each Revenue plot on either side will be taken into account to make it 3.1 m. and 5.1 m. wide road correspondingly
New Area (Residential)
Sl. No.
Maximum Length of the road in Meter
Minimum width of road of street in Meter
1
Up to 100
6.10
2
More than 100 to 250
7.5
2
More than 250 to 500
9.10
3
More than 500 to 1000
12.20
4
More than 1000
15.30
35. Minimum size of plots and road width
35.1 The minimum size of plots and road width for different categories of building is given in Table 7.
Table - 7: Category wise size of plots
Category
Min. road width (m)
Min. size of plot in Sqm.
Marriage Halls
12.20
1000
Cinema, Multiplex, Shopping Malls, Convention centers, Game centers,
18.30
2000
Social clubs and amenities
12.20
1000
Multi storey car parking
12.20
1000
Office buildings
12.20
300
Primary/Upper Primary school
09.00
2000
High School, Residential School
12.20
6000
+2 College / Junior College
12.20
4000
Degree College
12.20
6000
Technical educational institution
12.20
10000
Petrol Pumps/Filling stations
12.20
500
Restaurant
12.20
500
LPG storages
12.20
500
Places of congregation
12.20
500
Public libraries
12.20
300
Conference hall
12.20
1000
Community hall
12.20
500
Nursing homes/polyclinics/Hospital
12.20
300
Hotel (below three star)
12.20
1000
Hotel (three star and above)
18.30
2000
R&D Lab
18.30
1500
Group Housing
6.10
3000
ormno here of √
Note:
(1) In exceptional cases the Authority may consider revising the minimum size of plot with the approval of the Government.
(2) The above (requirement) area of minimum size of the plot may be relaxed by 5% while sanctioning the plan.
(3) No high rise building (building with a height above 16.4 meters) shall be allowed on a plot size less than 1000 sqm.
(4) Minimum existing road width for building more than 13.3 m in height shall be not less than 6.1 m.
(5) For all plots abutting a road less than 12.2m width for proposed to be used for Primary/Upper Primary School a lay-by of paved area contiguous to the road for turning of vehicles and fire engines should be left. This lay-by should be of minimum dimension of 9m x 9m.
36. Minimum setbacks & Height for non-high rise buildings
(1) The minimum setbacks and height of buildings permissible in a given size/plot for residential in non high rising category shall be as per Table 8 and 9. The minimum setback for commercial and mercantile buildings shall be as per Table 10 and 11.
Table - 8: Minimum Front and Rear setbacks and height of residential buildings
Sl.
Average Depth of plot (In meters)
Building Height Upto G+2 Maximum-10m
Building Height Upto G+3 Maximum-13.3m
Building Height Upto G+4 Maximum-16.4m
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Front set back (m)
Minimum Rear set back (m)
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
(viii)
1
Upto 10m
1.5
0.90
No construction shall be permitted
No construction shall be permitted
2
Exceeding 10m & upto 15m
2.0
1.5
3.0
1.5
No construction shall be permitted
3
Exceeding 15m & upto 21m
2.5
1.5
3.0
1.8
3.0
3.0
4
Exceeding 21m & upto 27m
3.0
1.8
3.0
2.0
3.5
3.0
5
Exceeding 27m & upto 33m
4.0
2.5
4.0
3.0
4.0
3.5
6
Exceeding 33m & upto 39m
4.0
3.0
4.5
4.0
4.5
4.0
7
Exceeding 39m & upto 45m
4.0
4.0
4.5
4.0
5.0
4.5
8
More the 45m
4.0
4.0
5.0
5.0
6.0
5.0
anno
SΔ APQ = SΔ AQP + SΔ PQR
X
Table 9.Minimum Side setbacks for residential buildings
37. Minimum setbacks for high rise buildings
(1) For high-rise/ multi-storied buildings, the open spaces around the building unless or otherwise specified shall be as given in the Table 14.
Table -14Minimum exterior open spaces around the buildings for all type of high rise buildings unless otherwise specified
SI.
Height of the Building Upto (m)
Exterior open spaces to be left out on all sides in m.
Front setback
Side and Rear setback
1
More than 16.4 and upto 19.25m
6.5
4.5
2
More than 19.25m and upto 23.10m
7.5
4.5
3
More than 23.10m and upto 30m
8.0
5.0
4
In case of buildings of more than 30m height, for every increase in height of 3.35m. or fraction thereof or addition of one floor, 1m. in the front set back and 0.75 m. in the sides and rear setbacks shall be added.
Note:-
(1) In no case the minimum setbacks shall be less than those specified in sub-section 42.1 of these Bye Law for high rise buildings in the mentioned category.
(3) In case of multi storied buildings the exterior open space around a building shall be of hard surface capable of taking load of fire, engine weighting up to 45 tones.
Note- If the developments only on one side of the means of access, the prescribed widths maybe reduced by 1.0 meter each case. In no case, development on plots shall be permitted unless it is accessible by a public street of width not less than 6 m.
New Area (Non residential)
Sl. No.
Maximum Length of the road in Meter
Minimum width of road of street in Meter
1
200
7.5
2
400
9.1
3
600
12.2
4
above 600
15.30
Further, in no case the means of access shall be lesser in width than the internal access ways in layouts and subdivision.
34.2 No building construction activity of height more than 8 m. shall happen on a road with a width of less than 3.6 m. (Including Road Widening) in old area.
34.3 For roads of width 18.30 (60 ft.) and above there shall be no restriction on height and number of floors. However it may be regulated by the Master Plan/Development Plan/Zonal Plan.
34.4 Unless and otherwise specified, development of plots shall, not be permitted unless it is accessible by a public/private street with the width specified in these bye laws. The width of the road may be increased in a master plan/development plan/zonal plan but under no circumstance the provisions for width of road shall be less than the provisions made under these bye laws.
34.5 In case of institutional, administrative, assembly, industrial and other non residential and commercial activities, the minimum road width shall be 9.0 meters.
34.6 In case public land is not available for the road, all the plot owners on both sides of the road shall equally surrender their right over the land to the authority to accommodate the road width. The centre line of the road shall be taken as reference for such surrenders.
34.7 In case of a private road, which gives access to one or more buildings, the owner of the said private road shall develop the road and storm water drain as required by the Authority, and transfer the same to the Registered Residents' Welfare Association for maintenance.
omm²
(1)/(2) 为对称轴的直线。
34.8 Access from highways/important Roads-No premises other than, highway amenities like petrol pumps, motels, etc, shall have an access direct from highways and other roads designated by the Road Construction Department. The Road Construction Department shall notify a list of road, which shall not provide direct access to a specified class of buildings. The Authority shall maintain a register of such roads, which shall be open to public inspection at all times during office hours and published on the web site. These provisions shall, however, be subject to the provisions of the relevant State Highway Act, and National Highway Act.
34.9 The provisions of road width shall be strictly enforced. There shall be no construction over the prescribed road width. Any violation shall be treated as an offence under the Jharkhand Municipal Act-2011 in addition to provision for removal of illegal encroachment under the relevant Acts.
34.10 Strict steps shall be taken to remove any illegal encroachment which may have resulted in reduction of any road width. the personnel responsible for such illegal encroachment shall be severely dealt with and prosecuted as per law.
Sl.
Average Width of plot (in meters)
Building Height Upto G+2 Maximum-10m
Building Height Upto G+3 Maximum-13.3m
Building Height Upto G+4 Maximum-16.4m
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
(viii)
1
Upto 10m
At least one side from 0.90 m.
No construction shall be permitted
No construction shall be permitted
2
Exceeding 10m & upto 15m
0.90
0.90
0.90
0.90
No construction shall be permitted
3
Exceeding 15m & upto 21m
1.0
1.0
1.5
1.5
2.0
2.0
4
Exceeding 21m & upto 27m
1.5
1.5
2.0
2.0
2.5
2.5
5
Exceeding 27m & upto 33m
1.5
1.5
2.5
2.5
3.0
3.0
6
Exceeding 33m & upto 39m
2.0
2.0
3.0
3.0
3.66
3.66
7
Exceeding 39m & upto 45m
3.0
3.0
3.66
3.66
4.50
4.50
8
More the 45m
3.66
3.66
4.00
4.00
5.00
5.00
Table 10.Minimum front and rear setback for commercial/mercantile buildings
SI.
Average Depth of plot (In meters)
Building Height up to 16.4 m
Minimum Front set back (m)
Minimum Rear set back (m)
(i)
(ii)
(iii)
(iv)
1
Upto 10m
No construction is allowed
2
Exceeding 10m & upto 15m
4.5
3.0
3
Exceeding 15m & upto 21m
5.5
4.0
4
Exceeding 21m & upto 27m
6.0
4.0
5
Exceeding 27m & upto 33m
6.5
4.0
6
Exceeding 33m & upto 39m
7.0
4.5
7
Exceeding 39m & upto 45m
7.5
4.5
8
More than 45m
8.0
5.0
Table 11.Minimum side setbacks for commercial/mercantile buildings
Sl.
Average width of plot (In meters)
Building Height up to16.4m
Minimum Left set back (m)
Minimum Right set back (m)
(i)
(ii)
(iii)
(iv)
1
Upto 10m
At least one side 1.5 m.
2
Exceeding 10m & upto 15m
2.0
2.0
3
Exceeding 15m & upto 21m
2.5
2.5
4
Exceeding 21m & upto 27m
3.0
3.0
5
Exceeding 27m & upto 33m
4.0
4.0
6
Exceeding 33m & upto 39m
4.0
4.0
7
Exceeding 39m & upto 45m
5.0
5.0
8
More than 45m
5.5
5.5
Table 12.Open spaces around industrial buildings
Sl.
Plot Size
Minimum Front set back (m)
Minimum Rear set back (m)
Minimum Sides set back (m)
(i)
(ii)
(iii)
(iv)
(v)
1
550 sqm to 1000 sqm
9.0
4.5
4.5
2
1000 sqm to 5000 sqm
10.0
6.0
6.0
3
5000 sqm to 30000 sqm
12.0
9.0
9.0
4
Above 30000 sqm.
15.0
12.0
10.0
(1) α + h 2y2 = (x)/(2)
Table 13.Minimum set back for industrial building constructed over plot size upto 550 sqm.