43.4.1 Every exit doorway shall open into a enclosed stairway, a horizontal exit, on a corridor or passageway providing continuous and protected means of egress.
43.4.2 No exit doorway shall be less than 1.00 m. in width. Doorways shall be not less than 2.00 m. in height.
43.4.3 Exit doorways shall open outwards, that is away from the room but shall not obstruct the travel along any exit. No

door, when opened shall reduce the required width of stairway or landing to less than 90cm. Over head or sliding doors shall not be installed.
43.4.4 Exit door shall not open immediately upon a flight or stairs; a landing equal to at least the width of the door shall be provided in the stairway at each doorway; level of landing shall be the same as that of the floor which it serves.
43.4.5 Exit doorways shall be operable from the side which they serve without the use of key.