Part 3 Development Control Rules and General Building Rfouidfuwnte
1. SHORT TITLE, APPLICABILITY & COMMENCEMENT:
(a) These Rules may be called ‘The Andhra Pradesh Building Rules - 2012’.
(b) They shall apply to the building activities in the areas falling in;
(i) Hyderabad Metropolitan Development Authority (HMDA),
(ii) All Urban Development Authorities,
(iii) All Municipal Corporations,
(iv) All Municipalities,
(v) All Nagar Panchayats,
(vi) Gram Panchayat areas covered in Master Plans/General Town Planning Schemes notified under Andhra Pradesh Town Planning Act,1920 and
(vii) Industrial Area Local Authority (IALA) / Special Economic Zone (SEZ) notified by Government.
(c) These rules shall apply to all building activity. All existing rules, regulations, byelaws orders that are in conflict or inconsistent with these Rules shall stand modified to the extent of the provisions of these rules.
(d) They shall come in to force from the date of publication in the Andhra Pradesh Gazettee.
2. DEFINITIONS: In these rules,
(a) ‘Competent Authority’ means:
(i) The Metropolitan Commissioner, Hyderabad Metropolitan Development Authority in HMDA area exclusive of Greater Hyderabad Municipal Corporation (GHMC) Area,
(ii) The Commissioner, Greater Hyderabad Municipal Corporation (GHMC)
(iii) The Vice Chairman of the respective Urban Development Authority.
(iv) The Director of Town & Country Planning in case of Municipal Corporations, Municipalities, Nagara Panchayats not covered in Urban Development Authorities and Gram Panchayat areas covered in Master Plans / General Town Planning Schemes notified under Andhra Pradesh Town Planning Act, 1920.
(a) Water Bodies
(i) No building / development activity shall be allowed in the bed of water bodies like river or nala and in the Full Tank Level (FTL) of any lake, pond, cheruvu or kunta / shikam lands.
Unless and otherwise stated, the area and the Full Tank Level (FTL) of a Lake / Kunta shall be reckoned as measured and as certified by the Irrigation Department and Revenue Department.
(ii) The above water bodies and courses shall be maintained as Recreational/Green Buffer Zone and no building activity shall be carried out within:
(1) 100m from the boundary of the River outside the Municipal Corporation / Municipality / Nagara Panchayat limits and 50m with in the Municipal Corporation / Municipality / Nagara Panchayat limits. The boundary of the river shall be as fixed and certified by the Irrigation Department and Revenue Department.
(2) 30m from the FTL boundary of Lakes / Tanks / Kuntas of area 10Ha and above.
(3) 9m from the FTL boundary of Lakes / Tanks / Kuntas of area less than 10Ha / shikam lands;
(4) 9m from the defined boundary of Canal, Vagu, Nala, Storm Water Drain of width more than 10m.
(5) 2m from the defined boundary of Canal, Vagu, Nala, Storm Water Drain of width up to 10m.
(iii) Unless and otherwise specified in the Master Plan / Zonal Development Plan.
(1) In case of (ii) (1) & (2) above, the buffer zone may be utilised for road of minimum 12m width, wherever feasible.
(2) In case of (ii) (2) above, in addition to development of recreational / green belt along the foreshores, a ring road or promenade of minimum 12m may be developed, wherever feasible.
(3) The above buffer zone to be left may be reckoned as part of tot lot or organized open space and not for setback requirements.
(iv) In case of Protection of Catchment area of Osmansagar and Himayatsagar lakes covered under the G.O.Ms.No.111 MA dated 08.03.1996, the restrictions on building and development activity imposed there in shall be applicable in Hyderabad Metropolitan Development Authority (HMDA) area.
(v) In case of areas along the Sea Coast, the Coastal Regulation Zone (CRZ) regulations shall be followed.
(b) Railways
The distance between the Railway Property Boundary and the edge of the building shall be 30m as per Indian Railways Works Manual or as per No Objection Certificate (NOC) given by the Railway Authorities.
(b) ‘Enforcement Authority’ means:
(i) The Metropolitan Commissioner, Hyderabad Metropolitan Development Authority.
(ii) The Vice Chairman of the respective Urban Development Authority.
(iii) The Commissioner of respective Urban Local Body.
(iv) The Executive Authority of the Gram Panchayat.
(v) The Executive Authority of the Special Unit created as the case may be for the purpose of sanctioning and monitoring building and development activity, as applicable.
(c) ‘Group Development Scheme’ is reckoned as development of Residential Buildings in a Campus or Site of 4000sq.m and above in area and could be row houses, semi-detached, detached Houses, Apartment blocks or High-Rise buildings or mix or combination of the above.
(d) ‘Group Housing’ means the development of building having 5 or more multiple dwelling units and common services on a given site or plot in a single or multiple blocks without customary subdivision of land by way of individual plots.
(e) ‘Height of Building’ means height measured from the abutting road and in case of undulated terrain height can be considered as average of the corresponding ground level. The parapet wall, staircase head room, lift room, water tank are excluded from the height of the building.
(f) ‘High-Rise Building’ means a building with 18m or more in height. However, chimneys, cooling towers, boiler rooms, lift machine rooms, cold storage and other non-working areas in case of industrial buildings and water tanks and architectural features in respect of other buildings are excluded.
(g) ‘Parking Complex/Parking Lot’ means premises either built or open which is utilized purely for parking of vehicles permitted in specific areas.
(h) ‘Sanctioning Authority’ means:
(i) The Metropolitan Commissioner, Hyderabad Metropolitan Development Authority.
(ii) The Vice Chairman of the respective Urban Development Authority.
(iii) The Commissioner of respective Urban Local Body.
(iv) The Executive Authority of the Gram Panchayat.
(v) The Executive Authority of the Special Unit created as the case may be for the purpose of sanctioning and monitoring building and development activity, as applicable.
(i) ‘Transferable Development Right (TDR)’ means an award specifying the built up area an owner of a site or plot can sell or dispose or utilize elsewhere, in lieu of surrendering land free of cost which is required to be set apart or affected for public purpose as per the Master Plan or in road widening or covered in recreational use zone, etc. The award is in the form of a TDR Certificate issued by the Competent Authority.
Terms and expressions which are not defined in these Rules shall have the same meaning as in the respective rules / regulations / byelaws of the respective local authorities and as defined in the National
Building Code as the case may be, unless the context otherwise requires.
3. RESTRICTION OF BUILDING ACTIVITY IN THE VICINITY OF CERTAIN AREAS:
(c) Electrical Lines
(i) In case of sites in the vicinity of High Tension Electricity Transmission Lines besides taking other safety precautions, a minimum safety distance (both vertical and horizontal) of 3m shall be maintained between the building and the High Tension Electricity
Lines and 1.5m shall be maintained between the building and the Low Tension Electricity Lines.
(ii) In case of Electricity Tower lines, the land all along below the tower line shall be developed as green belt to an extent of the width of tower base and on either side of green belt there shall be a minimum of 10m wide roads or as defined in the Master Plan.
(d) Airport
(ii) Other Structures
(1) No chimneys or smoke producing factories shall be constructed within a radius of 8km from the Airport Reference Point.
(2) Slaughter House, Butcheries, Meat shops and Solid Waste Disposal Sites and other areas for activities like depositing of garbage which may encourage collection of high flying birds, like eagles and hawks, shall not be permitted within 10 km from the Airport Reference Point.
(3) Within a 5km radius of the Aerodrome Reference Point, every structure/installation/building shall be designed so as to meet the pigeon/bird proofing requirement of the Civil Aviation Authorities. Such requirement may stipulate the prohibition of any cavity, niche, or other opening on the exterior of such building/installation/structure so as to prevent the nesting and habitation of pigeon or other birds.
(i) Building Restrictions
(1) For building activity within the Restricted Zone / Air Funnel Zone near the airport, necessary clearance from the concerned Airport Authority shall be obtained.
(2) The building heights and other parameters shall be regulated as per the stipulations of the Airport Authority of India as notified in Gazette of India Extraordinary (S.O.1589) dated 30-06-2008 and as amended from time to time by Ministry of Civil Aviation, Government of India.
(3) Irrespective of their distance from the aerodrome, even beyond 22km limit from the Aerodrome Reference Point, no radio masts or similar installation exceeding 152m in height shall be erected except with the prior clearance from Civil Aviation Authorities.
(4) In respect of any land located within 1000m from the boundary of Military Airport no building is allowed except with prior clearance from the concerned airport authority with regard to building height permissible and safe distance to be maintained between the building and boundary of the aerodrome.
(h) Heritage Structures
(i) In case of Sites located within the distance up to 100m from protected monuments as notified under Archeological Monuments and Ancient Sites and Remains Act 1955 and as amended no construction is allowed.
(ii) For the Sites located within distance of above 100m and up to 200m from the protected monuments, the construction is allowed only after obtaining prior permission from the National Monument Authority.
(iii) For the Sites located within the vicinity of any Heritage Structure notified as per the respective law, the prior clearance from the concerned authority shall be obtained.
(iv)For the development / redevelopment of any notified Heritage Structure the stipulations as prescribed by the respective authority shall be followed.
(i) Religious Structures
(i) In case of Sites located within a radius of 100m from the notified religious structure as given in the list in Annexure – VII / notified from time to time, the construction is allowed up to 10m height only.
(ii) For the Sites located within a radius of above 100m and up to 300m from the notified religious structure as given in the list in Annexure – VII / notified from time to time, only non high rise structures are allowed.
(e) Provisions laid under Environmental Impact Assessment Notification-2006:
As per the provisions laid under the EIA Notification S.O.1533, Dt.14.9.2006 and it’s amendment dt.01.12.2009 issued by MOE&F, GOI and Notifications issued from time to time with reference to “Building / Construction Projects/ Area Development Projects and Townships” complying with the following threshold limits fall under category B and are required to obtain prior Environmental Clearance (EC) from State Environmental Impact Assessment Authority (SEIAA), Ministry of Environment and Forests, Government of India.
Building/Construction P Project / Activity
rojects/Area Developmen B Category with threshold limit
t Projects and Townships Conditions, if any
8(a)
Buildings and Construction Projects
>20000sq.m and <1,50,000sq.m of built up area#
#(Built up area for covered construction; in case of facilities open to the sky, it will be the activity area
8(b)
Townships and
Covering an area >
++All Projects under
Area
50ha and or built up
Item8(b) shall be
Development
area >1,50,000sq.m
appraised as Category
Projects
++
B1
(f) Defense Establishments
(i) In case of Sites within 500m distance from the boundary of Defense Areas / Military Establishments prior clearance of Defense Authority shall be obtained.
(ii) In case of Naval Science and Technological Laboratory (NSTL), Visakhapatnam, no building shall be allowed with in a distance of 20m from the boundary wall of NSTL, Visakhapatnam.
(g) Oil / Gas Pipelines
In case of Sites in the vicinity of Oil / Gas pipelines, clearance distance and other stipulations of the Respective Authority shall be complied with. The Oil / Gas Authorities shall also specify the clearances required stretch wise to Local Body.
(j) Special Regulations for Banjara Hills & Jubilee Hills Areas of Hyderabad
(i) The following are the Special Regulations to maintain special characteristics of Banjara Hills and Jubilee Hills areas covered by Block 1 & 2, and part of Block No. 3 of Ward no. 8, of erstwhile Municipal Corporation of Hyderabad area of GHMC.
(ii) The building with height beyond 10m in these areas shall be permitted only if the plot abuts to a minimum of 12m wide road.
(iii) In case of Jubilee Hills Co-operative House Building Society and Prashasan Nagar Co-operative House Building Society Layout, Jubilee Hills the height of the building is restricted to 10m excluding stilt with a maximum FAR of 1:1.
(iv) In case of plots abutting Road No.1, 2 & 3 Banjara Hills and Road No.36 Jubilee Hills the building height shall be limited to 30m and further the said height relaxations are allowed only on plots where the land owners have surrendered their land in the past or will surrender their land free of cost to Municipal Corporation for road widening.
(v) The setbacks shall be followed as per Table-III of rule-5 and also parking & other requirement shall be as per these rules.
4. REQUIREMENT OF APPROACH ROAD FOR BUILDING SITES / PLOTS:
(a) The minimum abutting existing road width required for various uses of building activities shall be as given below.
TABLE – II
Category
Type / Use of Building Plot permissible
Minimum abutting existing road width required (in meters)
A
SITES IN OLD /EXISTING BUILT-UP AREAS /CONGESTED AREAS /SETTLEMENT / GRAM KHANTAM/ABADI (see Annexure-I)
A
All Residential (other than Group Housing) & Commercial Buildings with maximum permissible height of 10 m For other categories the Minimum road width shall be as given in B1 Category
9 *
B
SITES IN NEW AREAS / APPROVED LAYOUT AREAS
B 1
Non-High Rise (Residential) Buildings including Group Housing (Cellar and / or Stilt as permissible + maximum up to 5 floors), Basic level social amenities like Nursery School, Primary School / Religious Place /Clinic / Dispensary / Diagnostic Laboratory
9 **
B 2
High Rise Buildings / Complexes up to height of 24 meters, Non High Rise Group Housing (Cellars as applicable + 6 floors), Group Housing with more than 100 units, Group Development Scheme; Middle school / Tutorial institution / General Industry / Godown / Petrol / Diesel/ Gas Filling Station; High School, Junior College/ Commercial Complex, Computer units /Office Building, ITES Complex, Nursing Home /Hospital of not more than 20 beds / Community Hall/Function/Marriage Hall/ Assembly Hall/Cinema Theater; Service establishment / Workshop; Others not specified in the Table and all Non High-Rise buildings up to 18m height
12
B 3
General Degree and other non-professional College / Polytechnic, ITI; Professional College Campus; Multiplex Complexes, Shopping Malls (above 4000sq.m), Hospitals of more than 20 beds and all High-Rise buildings above 24m and up to 30 m height
18
B4
All High Rise Building above 30 meters will be permitted as per the Minimum Road width and setbacks as specified in Table-IV of rule-7
All High Rise Building above 30 meters will be permitted as per the Minimum Road width and setbacks as specified in Table-IV of rule-7
(b)*In case of Sites in Category-A, if a Site is abutting to a road which is less than 9m in width, a building may be permitted with a maximum height of 10m in such site, after leaving 4.5m from the Centre Line of such road for widening and the same shall be handed over to the Local Body and shall leave the prescribed setback as per Table-III after the said road widening portion. No relaxations are permissible in such cases.
(c) **In case of Sites in Category-B, if a Site is abutting to a road which is less than 9m in width, Individual Residential Building may be permitted with a maximum height of 12m, after leaving 4.5m from the Centre Line of such road for widening and the same shall be handed over to the Local Body and shall leave the prescribed setback as per Table-III of rule-5 after the said road widening portion. No relaxations are permissible in such cases.
(d)In case of Notified Slums / Economically Weaker Section (EWS) Buildings, the special regulations as notified by the Government from time to time shall be followed.
(e)The sites in old / Existing Built-up Areas / Congested Areas / Settlement / Gram Khantam / Abadi (Annexure-I) and List of Areas Prohibited for High-Rise Buildings (Annexure-II) shall be notified by the Local Bodies in consultation with the Competent Authority. The Government may add to or delete from the list of the said areas.
(f) In case of single plot sub-division approved by the competent authority, a means of independent access of minimum 3.6m pathway may be considered for Individual Residential Building and 6m for Non-High-Rise Group Housing Building.
PERMISSIBLE SETBACKS & HEIGHT STIPULATIONS FOR ALL TYPES OF NON-HIGH RISE BUILDINGS (Buildings below 18m in height inclusive of Stilt / Parking Floor):
(a) The height of buildings permissible in a given site / plot shall be subject to restrictions given in Annexure - I to II.
(b) The minimum setbacks and permissible height as per Table - III and other conditions stipulated below shall be followed.
TABLE – III
Sl. No.
Plot Size (in Sqm) Above - Up to
Parking provision
Height (in m) Permissi ble Up to
Building Line or Minimum Front Setback to be left (in m)
Minimum setbacks on remaining sides (in m)
Abutting Road Width
Up to12m
Above 12m & up to 18m
Above 18m & up to 24 m
Above 24m & up to 30m
Above30m
1
2
3
4
5
6
7
8
9
10
1
Less than50
7
1.5
1.5
3
3
3
-
2
50-100
-
7
1.5
1.5
3
3
3
-
10
1.5
1.5
3
3
3
0.5
3
100 -200
-
10
1.5
1.5
3
3
3
1.0
4
200 -300
Stilt floor
7
2
3
3
4
5
1.0
10
2
3
3
5
6
1.5
5
300 -400
Stilt floor
7
3
4
5
6
7.5
1.5
12
3
4
5
6
7.5
2.0
6
400 -500
Stilt floor
7
3
4
5
6
7.5
2.0
12
3
4
5
6
7.5
2.5
7
* 500 -750
Stilt floor
7
3
4
5
6
7.5
2.5
12
3
4
5
6
7.5
3.0
15
3
4
5
6
7.5
3.5
8
750 -1000
Stilt + One Cellar floor
7
3
4
5
6
7.5
3.0
12
3
4
5
6
7.5
3.5
15
3
4
5
6
7.5
4.0
9
1000 -1500
Stilt + 2 Cellar floors
7
3
4
5
6
7.5
3.5
12
3
4
5
6
7.5
4.0
15
3
4
5
6
7.5
5.0
18**
3
4
5
6
7.5
6.0
10
1500 -2500
Stilt + 2 Cellar floors
7
3
4
5
6
7.5
4.0
15
3
4
5
6
7.5
5.0
18**
3
4
5
6
7.5
6.0
11
Above2500
Stilt + 2 or more Cellar floors
7
3
4
5
6
7.5
5.0
15
3
4
5
6
7.5
6.0
18**
3
4
5
6
7.5
7.0
(c) Stilt Floor meant for parking is excluded from the permissible height in the above Table. Height of stilt floor shall not be less than 2.5m. In case of parking floors where mechanical system and lift are provided, height of such parking floor shall not be less than 4.5m.
(d) *In case of commercial buildings proposed in plots having an extent of 500-750sq.m cellar floor for parking may be considered subject to condition that required parking shall be fulfilled as per Table-V of rule-13 and feasibility on ground.
(e) **Buildings of height above 15m and below 18m in Sl.Nos.9, 10 and 11 above, shall be permitted only if such plots abut minimum 12m wide roads only.
(f) Other conditions:
(i) The setbacks are to be left after leaving the affected area of the plot / site, if any, for road widening.
(ii) Where a site abuts more than one road, then the front setback should be insisted towards the bigger road width and for the remaining side or sides, the setback as at Column-10 shall be insisted. In case of individual residential buildings the option is given to the applicant to propose front setback on one of the roads. In such case he shall not have access from the other side / sides. On the other side / sides the applicant can leave the setback either as per the required front setback based on the road width or to provide the side setback as given in Column-10.
(iii) A strip of at least 1m greenery / lawn along the frontage of the site within the front setback shall be developed and maintained with greenery.
(iv) For Plots above 300sq.m in addition to (iii) above, a minimum 1m wide continuous green planting strip in the periphery on remaining sides are required to be developed and maintained within the setback.
(v) For all residential / institutional / industrial plots above 750sq.m, in addition to (iii) and (iv) above, 5% of the site area to be developed as organized open space and be utilized as greenery, tot lot or soft landscaping etc., and shall be provided over and above the mandatory setbacks. Such organized open space could be in more than one location and shall be of a minimum width of 3m with a minimum area of 15sq.m at each location.
(vi) If the strip of greenery / lawn and the organized open space (tot lot) are not maintained, 10% of additional Property Tax every year would be imposed as penalty by the Sanctioning Authority till the condition is fulfilled.
(vii) In all plots 750sq.m and above, provision shall be made for earmarking an area of 3m X 3m for the purpose of setting of public utilities like distribution transformer, etc. within the owner’s site subject to mandated public safety requirements.
(viii) In case of plots 300 - 750sq.m, it is permitted to transfer up to 1m of setback from any one side to any other side without exceeding overall permissible plinth area. The transfer of setback from front setback is not allowed.
(ix) In case of plots above 750sq.m, it is permitted to transfer up to 2m of setback from any one side to any other side without exceeding overall permissible plinth area, subject to maintaining of a minimum 2.5m setback on other side and a minimum building line. The transfer of setback from front setback is not allowed.
(x) For narrow plots having extent not more than 400sq.m and where the length is 4 times of the width of the plot, the setbacks on sides
may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10m and minimum of 2m in case of buildings of height above 10m and up to 15m without exceeding overall permissible plinth area. (This Rule shall not be applicable for made-up plots).
(xi) Where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space / duct, such open space shall be open to sky and of area at least 9sq.m and no side shall be less than 2m. Such open spaces / ducts may be allowed above stilt floor.
(xii) The space between 2 blocks shall not be less than the side setback of the tallest block as mentioned in Table - III and this shall not be considered for organised open space (tot lot).
(xiii) Where all the owners of sites along an abutting road come forward for widening of the road by undertaking preparation of a Road Development Plan which would improve circulation in the area and duly approved by the competent authority, and by leaving the area affected in the widening of such road free of cost and implement it within one year, then higher height of the corresponding widened road width would be considered for such sites.
(xiv) Splay at road junctions, including ‘Y’ junctions shall be provided as follows. The area of such splay would be deemed to form part of the road junction.
Sl.No
Road Width (in m)
Splay / Offset (in m)
1
Less than 12
3 X 3
2
Above 12 up to 24
4.5 X 4.5
3
Above 24
6 X 6
(xv) As per the provisions of the Andhra Pradesh Fire Service Act, 1999, Residential buildings of height more than 18 m, Commercial buildings of height 15m and above and buildings of public congregation like Educational Buildings, Cinema Theatres, Function Halls and other Assembly Buildings on plot area of 500Sq.m. and above or of height above 6m are required to obtain prior clearance from Andhra Pradesh State Disasters Response & Fire Services Department from fire safety point of view.
(xvi) Stepped type buildings or incremental type buildings may be allowed only in respect of individual residential or educational / institutional buildings and such incremental development would be considered only after a minimum time period of 5 years.
(xvii) For the purpose of these Rules, the following conversion from M.K.S. and F.P.S. system shall be reckoned for the road widths only:
(xviii) All building applications for sanction of building permission for construction of above 10m height shall be accompanied with the following details:
(a) Report of Soil Test / Geo-technical Investigation Report issued after personal inspection by Institution / Consultant empanelled with / licenced by the local authority.
(b)Structural designs and drawings prepared duly taking the soil bearing capacity into consideration and certified by qualified Structural Engineer / Consultant Firm empanelled with / licenced by the local authority. The Structural Engineer / Consultant Firm is held responsible for defect in the design.
(c) Building Plan and Application shall be invariably signed by the owner of the property, builder if any, the Architect and the Structural Engineer who designed the structure. They shall give their present and permanent addresses.
(d)If the construction is being taken up by a builder, an attested copy of the registered agreement entered between the owner of the property and the builder shall be submitted. In case of any changes in the agreement at a later date, a copy of the same shall also be submitted to the local authority.
(e)An undertaking on a Stamp Paper of Rs.100/-duly signed by the owner and builder specifying that no flat or built-up area shall be given possession to the purchaser / tenant unless they obtain the occupancy certificate from the local authority and provide all regular service connections.
(f) Contractor / Builders / Developer / Owner shall submit All Risks Insurance Policy for the construction period.
6. RESTRICTIONS ON PROJECTIONS IN MANDATORY OPEN SPACES:
The following are the Restrictions on Projections in the mandatory open spaces / setbacks / interior open spaces:
(a) Cornice, Chajjas / weather shades only of width not exceeding 60cm shall be allowed in the mandatory setbacks.
(b) No balcony projections or corridor shall be permitted projecting within the mandatory open spaces / setbacks in case of non-high rise buildings. These, if provided for, shall be set back as per the minimum mandatory open spaces and the setbacks shall be clear from the edge of the balcony or corridor. However, a Portico or Canopy without access to the top may be considered in the front open space.
(c) In case of Individual Residential Building in plots more than 300sq.m:
(i) In the front setback only a security guard booth of 2sq.m is allowed.
(ii) Septic tank, well may be allowed in the rear and side open spaces.
(iii) A setback of at least 1m from the property or boundary line of the plot shall be provided for these structures.
(iv) Parking sheds, generator room may be allowed in the rear and side open Spaces.
(v) The height of these accessory buildings shall not be more than 2.5m and shall not occupy more than 1/4th of the plot width. These shall be so located that they do not hinder the fire safety measures and operations.