To enable wheelchair users to pass through doors, the minimum clear width should be 900 mm and shall be operable by a single effort. In certain cases the clear width should be 900 mm to 1000 m, for example, if the wheelchair has to be turned in the doorway, where there is a door-closer or at entrance doors to public buildings and in other situations where there is considerable traffic.
D-3.3.1.1 Two-leaf doors are not usable by those with disabilities defined in D-1.2.1, D-1.2.2 and D-1.2.5 unless they operate by a single effort, or unless one of the two leaves meets the requirements of D-3.3.1.
D-3.3.1.2 Side-hung doors
To facilitate wheelchair manoeuvre, doors should be hung with the hinges in room corners. Doors opening out into corridors or circulation spaces should be avoided as far as possible.
D-3.3.1.3 It is recommended that all doors have kick plates extending from the bottom of the door to at least 400 mm from the floor, or be made of a material and finish that would safely withstand the abuse they might receive from canes, crutches, wheelchair foot platforms, or wheelchair wheels.
D-3.3.2 Wheelchair Manoeuvring Space
To enable wheelchair users to approach doors manoeuvring space is needed as shown in the Fig. 13. A corridor should have a width of at least 1 200 mm to allow a 90° turn to be made through a door. In narrow spaces sliding doors may be preferable.

NOTE — Depending on the free space beside the opening side (450 or 550 mm), the depth of free space should be 1 500 or 1400 mm.
FIG. 13 MANOEUVRING SPACE NEEDED FOR WHEELCHAIR USERS TO APPROACH DOORS
D.3.3.3 Threshalds
Raised thresholds should be avoided, but where this is not possible, their height should not exceed 25 mm, Rubber theresholds are advantageous for wheelchair users.
D.3.3.3.1 Care should be taken in the selection, placement and setting of door closers so that they do not prevent the use of doors by the physically disabled. Time-delay door closers are recommended.
D3.3.3.2 Self –Closing doors
Wheelchair user and other with impaired mobility have difficulty in using self –closing doors. The force required to open them should be reduced as for as possible. Public buildings should preferably have sliding automatic doors.
D.3.3.4 Door Identification
To help people with impaired vision to see doors, the door and frame should be in a colour which contrasts with the adjoining wall. Glass or glazed doors should be marked with a coloured band or frame a little below eye-level.
D.3.3.5 Handles
Door handles and locks should be easy to manipulate. To facilitate the closing of a door by wheelchair users (for example, a whiter closet compartment_. The door should have a horizontal handle approximately 800mm from the floor. Self –closing doors should be equipped with an easy gripped vertical pull-handle with a length of at least 300-mm , and with and the lower end approximately 800mm above floor. For many people and specially those with impaired vision. It is helpful to make clear whether doors are to be pulled or pushed

D-3.4 Windows
Windows should be designed to avoid the glare which is a particular problem for people with impaired vision. Large glass areas close to circulation spaces should be marked a little below eye-level with a coloured band or frame. To enable wheelchair users to see through a window comfortably, the sill should be easy to open and close. Their controls should be placed in the zone 900 to 1200 mm from floor (see Fig.15)