Classification of Buildings.- Buildings shall be classified on the basis of occupancy as follows :-
(a) Residential.
(b) Educational.
(c) Institutional.
(e) Business.
(f) Mercantile (Will including both retail and wholesale stores).
(g) Industrial (Will include low, moderate and high fire hazards).
(h) Storage.
(i) Hazardous.
मध्यप्रदेश राजपत्र, दिनांक 13 अपैल 2012
392 (227)
II Open Spaces (within a Plot)
General.- (1) Every room intended for human habitation shall abut on an interior or exterior open space or an open verandah open to such interior or exterior open space.
(2) Open spaces to cater for lighting and ventilation requirement. The open spaces inside or around building have essentially to cater for the lighting and ventilation requirements of the rooms abutting such open spaces and in the case of building abutting streets in the front, rear or sides, the open spaces provided shall be sufficient for the future widening of such streets.
(3) Open spaces separate for each building or wing. The open spaces shall be separate or distinct for each building and where a building has two more wings, each wing shall have separate or distinct open spaces for the purposes of light and ventilation of the wings.
(4) Separation between accessory and main buildings more than 7 meter in height shall not be less than 1.5 meters. For buildings up to 7 meters in height no such separation shall be required.
56Residential Buildings.- Open Spaces.
Exterior open spaces for buildings having height up to 12.5 meters.
(1) Front open spaces.
(a) Every Residential Building having height up to 12.5 meters, facing street shall have a front open space mentioned below and such open space shall form an integral part of the site:-
S. No.
Width of street facing the plot
Front open space Min.
(1)
(2)
(3)
1.
up to 9.0 meters
3.0 meters
2.
More than 9.0 meters and up to 12 meters
3.6 meters
3.
More than 12.0 meters and up to 18 meters
4.5 meters
4.
Above18 meters.
6.0 meters
392 (228)
(b) In existing developed areas with streets less than 6.0 meters in width the distances of the building (building line) shall be at 6.0 meters from the center line of the street.
(2) Rear Open Space.
(a) Every Residential Building, having height up to 12.5 meters, shall have a Rear Open Space, as below :-
Sr. No.
Plot area in Square meters
Building height in meters
Minimum Rear Open space in meters
(1)
(2)
(3)
(4)
1.
Up to 40.00
10.00
Nil
2.
Above 40.00 and Up to 150.00
10.00
1.50
3.
Above 150 and up to 225.00
10.00 and above
2.50
4.
Above 225.00
10.00 and above
3.00
(b) Rear open space to extend through the rear wall. The rear open space shall be co-extensive with the entire face of the rear wall. If a building abuts on two or more streets, such rear open space shall be provided through-out the entire face of the rear wall. Such rear wall shall be the wall on the opposite side of the face of the building abutting on the wider street unless the Authority otherwise directs:
(3) Side open space.
Every semi-detached and detached building shall have a permanently side open airspace, forming integral part of the site as below :-
(i) For detached buildings there shall be minimum side open spaces of 3 meters on both the sides :
Provided that for detached residential building up to 7 meters in height on plots with a frontage less than 12 meters, one of the sides open space may be reduced to 1.5 meters.
(ii) For semi-detached building there shall be a minimum side open space of 3.0 meters on one side. For Semi-detached building up to 10 meters in height on plots with a frontage up to 10 meters, the side open space may be
मध्यप्रदेश राजपत्र, दिनांक 13 अपैल 2012
392 (229)
reduced to 2.5 meters. In the case of semi-detached buildings, the open spaces provided on one side shall be as in this sub-rule and all habitable rooms shall abut either on this side open space or front and rear open spaces or an interior open space.
(iii) For row-type buildings, no side open space is required.
(4) Notwithstanding provision of sub-rule (2). and (3) garage may be permissible in rear end of the side open space.
(5) Open space for building of more than 12.5 meters height. For building of height above 12.5 meters the open spaces around building shall be as given in Table 4 and 5 of Rule 42.
(6) Interior open spaces for all buildings.
(a)·Inner Courtyard-
(i) Every room (except bath, water closet and store room) that does not abut on either the front, rear or side open spaces shall abut on an inner courtyard, whose minimum side shall be 3 meters.
(ii) Further the inner courtyard shall have an area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard.
Provided that when any room (excluding staircase bay, bathroom and water closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(ii). Where only water closet and bath room are abutting on the interior courtyard, the size of the interior courtyard shall be in line with the provision for ventilation shaft as given in clause (b).
(b) Ventilation Shaft. For ventilating the spaces for water closet and bath room in all types and height of buildings, if not opening on the front or side or rear or interior open spaces, shall open on to the ventilation shaft, the size of which shall not be less than the values given below :-
Height of buildings in meters
Size of ventilation shaft in square meters
Minimum size of a side of shaft in meters
(1)
(2)
(3)
Up to 10
1.2
0.9
12.5
2.8
1.2
392 (230)
18
4.0
1.5
24
5.4
1.8
30
8.0
2.4
above 30
9.0
3.0
Note 1 : For buildings above 30 meters mechanical ventilation system, shall be installed besides the provision of minimum ventilation shaft.
Note 2 : For fully air-conditioned residential buildings for lodging purposes the ventilation shaft need not be insisted :
Provided that the air-conditioning system is designed to work in an un-interrupted manner which means that there is an alternate source of power supply.
(c) Outer Courtyard. The minimum width of outer courtyard (distinguished from its depth) shall be than 2.4 meters. If the width of the outer courtyard is less than 2.4 meters, then it shall be treated as a notch and the provisions of outer courtyard shall not apply.
(7) Joint open air space for buildings.
(a) Every such interior or exterior open air space, unless the latter is a street, shall be maintained for the benefit of such building exclusively and shall be entirely within the owner's own premises.
(b) If such interior or exterior open air space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be equal to the one as specified for tallest building abutting on such open air space.
(c) If such interior or exterior open space is jointly owned by more than one person, then its width shall also be as specified in rule 59:
Provided that every such person agrees in writing to allow his portion of such joint open space to be used for the benefit of every building abutting on such joint open space and provided he submits his written consent to the Authority for record. Such common open space shall henceforth be treated as a permanently open space required for the purposes of these rules. No boundary wall between such joint open space shall be erected or raised to a height above 2.0 meters.