Exterior open spaces for buildings having height up to 12.5 meters.
(1) Front open spaces.
(a) Every Residential Building having height up to 12.5 meters, facing street shall have a front open space mentioned below and such open space shall form an integral part of the site:-
S. No.
Width of street facing the plot
Front open space Min.
(1)
(2)
(3)
1.
up to 9.0 meters
3.0 meters
2.
More than 9.0 meters and up to 12 meters
3.6 meters
3.
More than 12.0 meters and up to 18 meters
4.5 meters
4.
Above18 meters.
6.0 meters
392 (228)
(b) In existing developed areas with streets less than 6.0 meters in width the distances of the building (building line) shall be at 6.0 meters from the center line of the street.
(2) Rear Open Space.
(a) Every Residential Building, having height up to 12.5 meters, shall have a Rear Open Space, as below :-
Sr. No.
Plot area in Square meters
Building height in meters
Minimum Rear Open space in meters
(1)
(2)
(3)
(4)
1.
Up to 40.00
10.00
Nil
2.
Above 40.00 and Up to 150.00
10.00
1.50
3.
Above 150 and up to 225.00
10.00 and above
2.50
4.
Above 225.00
10.00 and above
3.00
(b) Rear open space to extend through the rear wall. The rear open space shall be co-extensive with the entire face of the rear wall. If a building abuts on two or more streets, such rear open space shall be provided through-out the entire face of the rear wall. Such rear wall shall be the wall on the opposite side of the face of the building abutting on the wider street unless the Authority otherwise directs:
(3) Side open space.
Every semi-detached and detached building shall have a permanently side open airspace, forming integral part of the site as below :-
(i) For detached buildings there shall be minimum side open spaces of 3 meters on both the sides :
Provided that for detached residential building up to 7 meters in height on plots with a frontage less than 12 meters, one of the sides open space may be reduced to 1.5 meters.
(ii) For semi-detached building there shall be a minimum side open space of 3.0 meters on one side. For Semi-detached building up to 10 meters in height on plots with a frontage up to 10 meters, the side open space may be
मध्यप्रदेश राजपत्र, दिनांक 13 अपैल 2012
392 (229)
reduced to 2.5 meters. In the case of semi-detached buildings, the open spaces provided on one side shall be as in this sub-rule and all habitable rooms shall abut either on this side open space or front and rear open spaces or an interior open space.
(iii) For row-type buildings, no side open space is required.
(4) Notwithstanding provision of sub-rule (2). and (3) garage may be permissible in rear end of the side open space.
(5) Open space for building of more than 12.5 meters height. For building of height above 12.5 meters the open spaces around building shall be as given in Table 4 and 5 of Rule 42.
(6) Interior open spaces for all buildings.
(a)·Inner Courtyard-
(i) Every room (except bath, water closet and store room) that does not abut on either the front, rear or side open spaces shall abut on an inner courtyard, whose minimum side shall be 3 meters.
(ii) Further the inner courtyard shall have an area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard.
Provided that when any room (excluding staircase bay, bathroom and water closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(ii). Where only water closet and bath room are abutting on the interior courtyard, the size of the interior courtyard shall be in line with the provision for ventilation shaft as given in clause (b).
(b) Ventilation Shaft. For ventilating the spaces for water closet and bath room in all types and height of buildings, if not opening on the front or side or rear or interior open spaces, shall open on to the ventilation shaft, the size of which shall not be less than the values given below :-
Height of buildings in meters
Size of ventilation shaft in square meters
Minimum size of a side of shaft in meters
(1)
(2)
(3)
[See rule 60(2)]
S. No.(1)
Gross residential density Persons/Hectare(2)
Maximum coverage in per cent.(3)
Floor area Ratio(4)
1.
125
25
0.75
2.
250
30
1.25
3.
425
33
1.50
4.
500
35
1.75
5.
625
35
2.00
Note: The coverage shall be calculated on the basis of the whole area reserved for group housing after deducting,-
(i) the area of any highway or any road of width 18 mtrs. or more which falls within the area of Group Housing;
(ii) the area of school (excluding sites for Nursery Schools) and other community facilities within the Group Housing Area; and
(iii) the open space except playgrounds and tot lots of local nature.
392 (234)
Floor Area Ratio.- The Floor Area Ratio (FAR) for different use group shall be as mentioned in Table 8.
Table 8
(See rule 61)
FLOOR AREA RATIO FOR DIFFERENT USE GROUP
S. No.(1)
Use Group(2)
FAR *(3)
Category(4)
1.
Residential
1.25
2.
Commercial
2.50
City Centre
2.001.75
Sub-city centerCommunity Center
1.501.00
Local Shopping CentreConvenience Shopping Centre
3.
PublicSemi-public
1.00
Administrative Areas /Education and Research/Health /Social / Cultural/Institutional
4.
Industrial
1.00
Plot Up to 250 square meters
0.90
Plot above 250 and upto 300 square meters
0.80
Plot above 300 and upto 0.80 Hectares
57Open spaces for other occupancies.- Open spaces for other occupancies shall be as follows :-
392 (231)
(a) Educational Buildings. Except for nursery school, the open spaces around the building shall be not less than 6 meters.
(b) Institutional Building. The open spaces around the building shall not be less than 6 meters.
(c) Assembly Building. The open space at front shall not be less than 12 meters and other spaces around the building shall not be less than 6 meters.
(d) Business, Mercantile and Storage Buildings. The open spaces shall not be less than 6 meters in the front and 4.5 meters on other three sides. Where these are situated in purely residential zone or residential with shops line zone, the open spaces may be relaxed.
(e) Industrial Buildings. The open spaces around the building shall not be less than 4.5 meters for heights up to 16 meters with an increase of the open spaces of 0.25 meters for every increase of 1 meter or fraction thereof in height above 16 meters.
(f) Hazardous occupancies. - The open space around the building shall be as specified for industrial buildings mentioned in clause (e) above.
Projections.- (1) Projection into open spaces. Every open space provided either on the interior or exterior side shall be kept free from any construction thereon and shall be open to the sky except as below :-
(a) Cornice, roof or weather shade not more than 0.75 meter wide;
(b) Sunshade over window/ventilators or other openings not more than 0.75 meters wide;
(c) Projected balcony at first or higher floors of width not more than 1.20 meters with clearance of 1.5 meters from plot boundary provided that such projected balcony shall not be constructed as a continuous projection on any side of the building;
(2) Projections mentioned above in sub-rule (1)(c) may be permitted on the inner and outer courtyards if the size of such courtyard is more than 9 meters x 9 meters.
(3) Projecting rooms at alternate floors may be allowed :
Provided that such projection,-
(a) do not obstruct the air and light of the lower two floors;
392 (232)
मध्यारदेश राजपत्र, दिनांक 13 अपैल 2012
(b) do not project into the MOS; and
Up to 10
1.2
0.9
12.5
2.8
1.2
392 (230)
18
4.0
1.5
24
5.4
1.8
30
8.0
2.4
above 30
9.0
3.0
Note 1 : For buildings above 30 meters mechanical ventilation system, shall be installed besides the provision of minimum ventilation shaft.
Note 2 : For fully air-conditioned residential buildings for lodging purposes the ventilation shaft need not be insisted :
Provided that the air-conditioning system is designed to work in an un-interrupted manner which means that there is an alternate source of power supply.
(c) Outer Courtyard. The minimum width of outer courtyard (distinguished from its depth) shall be than 2.4 meters. If the width of the outer courtyard is less than 2.4 meters, then it shall be treated as a notch and the provisions of outer courtyard shall not apply.
(7) Joint open air space for buildings.
(a) Every such interior or exterior open air space, unless the latter is a street, shall be maintained for the benefit of such building exclusively and shall be entirely within the owner's own premises.
(b) If such interior or exterior open air space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be equal to the one as specified for tallest building abutting on such open air space.
(c) If such interior or exterior open space is jointly owned by more than one person, then its width shall also be as specified in rule 59:
Provided that every such person agrees in writing to allow his portion of such joint open space to be used for the benefit of every building abutting on such joint open space and provided he submits his written consent to the Authority for record. Such common open space shall henceforth be treated as a permanently open space required for the purposes of these rules. No boundary wall between such joint open space shall be erected or raised to a height above 2.0 meters.
0.70
Plot above 0.80 Hectares and upto 1.20 Hectares
0.60
Plot above 1.20 Hectares and upto 2.80 Hectares
0.50
Plot above 2.80 Hectares.
* F.A.R and Density may be adopted as provided in the Development Plans of respective towns.
Note : (1) In case where the owner surrenders a portion of his plot / land and vests its ownership in the Government/Authority for public purpose, an additional floor area equal to twice the area of plot/land surrendered by him may be allowed in the remaining area of the plot/land in lieu of the monetary compensation.
मध्यप्रदेश राजपत्र, दिनांक 13 अगैल 2012
392 (235)
(2) In case of in-situ redevelopment of a slum, an additional FAR upto 0.50 may be allowed in addition to the permissible FAR in that area, however all other norms related to the development and building permission shall be observed.
(3) On plot admeasuring 200 to 500 sq. meters one servant quarter and on plot admeasuring more than 500 sq meters two servant quarters may be permitted. The size of a servant quarter shall not exceed 25 sq. m; and the area of the servant quarter shall not be counted in the built up area or the covered area.
(4) Covered parking with a clear height of 2.4 meters may be provided within the permissible ground coverage, on plots measuring 425 sq.m. or more. Such area of parking shall not be counted towards Floor Area Ratio and permissible height calculations.
(5) In case of redevelopment of areas in the old part of any city/town, the old and dilapidated structures may be reconstructed and if needed, an additional FAR up to an extent of 0.25 may be sanctioned over and above the permissible FAR of the area. However no other norm related to the development and building permission shall be relaxed.
Norms for Podium.- Podium is the over-ground covered parking space which is built over the ground coverage but does not extend into the prescribed minimum open spaces of the plot.
Podium may be constructed,-
(a) on a plot admeasuring at least 1000 sq.mtrs.;
(b) in such manner that the clear height of each floor does not exceed 2.4 meters; and
(c) with a maximum of three such floors above ground level.
Provided that such parking shall not be counted in the calculation of the Floor Area Ratio and the building height. The uncovered roof top portion of the podium may be used for development of uncovered park, water / swimming pool and parking.
Provided further that where mechanized parking is planned the restriction of 2.4 meters clear height may be relaxed according to the design needs. The maximum permissible height of the podium in such cases shall not exceed 2.4 m x 3 Floors + designed thickness of beams and slabs in Podium Parking Floor
Provided also that the uncovered roof top portion of the podium may be used for development of uncovered park, water / swimming
392 (236)
मध्यप्रदेश राजपत्र, दिनांक 13 अग्रैल 2012
pool, parking and may be counted towards the requirement of open spaces prescribed under rule 47 and 60 .
Parking Floors.- Where the plot size is not less than 1000sq. mtrs. covered parking with a clear height of not more than 2.4 meters may be permitted on any floor of the building according to the requirement of the project. Such parking shall not be included in the calculation of the FAR. If such parking is provided on the entire floor area, then such parking floor would not be included in the height of the building.
Service Floor.- Service floor may be provided in the building on plots having area 1000 square meters or more. The clear height of such service floor shall not exceed 2 meters and the same shall not be counted for the purpose of calculating Floor Area Ratio and the building height.
Height limit.-(1) The maximum height of a building and other planning norms shall be as per the provision of Table No 4 and 5 of Rule No 42 or as per rule 56, as the case may be.
(2) If a plot abuts on two or more streets of different widths, the building shall be deemed to face such street which has greater width and the height of the building shall be regulated by the width of that street. This height may be continued to a depth of 24 meters along the narrower street.
(3) In case the building is located in vicinity of aerodromes, the maximum height of such building shall be such as determined by the Airport Authority.
Note : The slaughter house / butcher house and other areas for activities like garbage dumps shall be permitted in accordance with the norms prescribed by the concerned airport authority.
Permission to build Skyway and subways.-(1) The Authority may permit the construction of skyway at different levels connecting two or more buildings.
Provided that no such skyway shall be built,-
(a) below a height of 6.5 meters as measured from highest level of the ground immediately below the skyway. However, this may be relaxed by the Authority if the nature of the movement under the skyway so permits.
(b) across any public street without obtaining the prior permission of the agency responsible for its construction and maintenance;
392 (237)
(c) without obtaining prior permission of the Fire Authority and a certificate of structural safety from the licensed structural engineer;
(d) in a manner that may obstruct any vehicular movement under it;
(e) with a width of more than 4 meters; and
(f) if the columns supporting such skyway do not harmonize with the surrounding architectural features.
(2) The Authority may permit the construction of a subway (an underground passage for pedestrian and /or vehicular use) with the object of connecting two or more points.
Provided that a subway for the use of pedestrians shall be built,-
(a) sufficiently below the ground to enable safe passage of vehicular or pedestrian traffic over it;
(b) across a public street after obtaining prior permission of the agency responsible for its construction and maintenance;
(c) after obtaining prior permission of the Fire Authority and a certificate of structural safety from the licensed structural engineer;
(d) in a manner that ensures that the lighting, drainage, ventilation, signage, utilities and services are comfortable and safe for the usage of the people; and
(e) with a clear height and width of not less than 3.0 meters and 4.5 meters respectively.
Note: If the subway is expected to allow vehicular traffic, the design parameters shall be approved by the Authority on case to case basis keeping in view the safety and comfort of the users.
Plantation.- In all new layouts having plot area of 100 square Meters or more shall be planted with trees after the completion of construction of building. The number of trees to be planted shall be worked out at one tree for every 100 square meters of individual plot. The occupancy certificate for the building will be issued only when the authority is satisfied that the provisions of this rule have been complied with. Every effort shall be made to protect the existing trees on the plot.
392 (238)
(c) shall not be more than the height of the storey immediately below.
(4) Accessory Building. The following accessory buildings may be permitted in the open spaces: -
(a) In existing building, sanitary block of 2.4 meters in height subject to a maximum of 4 square meters in the rear open space at a distance of 1.5 meters from the rear boundary may be permitted.
(b) Private garages with an area not exceeding 25 square meters shall be permitted in the side or rear open spaces such garage shall be at least at a distance of 7.5 meters from the front boundary of the plot :
Provided that construction up to one or more floor on the garage may be allowed. However, the area so allowed shall be included in the calculation of the built up area for the purpose of FAR; and
(c) Pump room up to 6.0 square meter.
(5) Sunshades over windows and ventilators.- Projections of sunshades over windows or ventilators in existing built-up or congested areas when permitted by the Authority shall fulfill the following conditions, namely :-
(a) no sun-shade shall be permitted over the road or over any drain or over any portion outside the boundaries of the site below a height of 2.8 meters from the road level;
(b) sunshades provided above a height of 2.8 meters from the ground level shall be permitted to project up to a maximum width of 60 centimeters, if the road over which they project exceeds 9 meters in width; and
(c) no sunshade shall be permitted on roads less than 9 meters width or on roads having no footpath.
Limitation to open spaces.- (1) Safeguard against reduction of open spaces. No construction work on a building shall be allowed if such work operates to reduce an open space of any other adjoining building belonging to the same owner to an extent less than what is prescribed at the time of the proposed work or to reduce further such open space if it is already less than that prescribed.
मध्यप्रदेश राजपत्र, दिनांक 13 अगैल 2012
392 (233)
(2) Additions or Extensions to a building. Additions or extensions of building shall be allowed :
Provided that the open spaces for the additions or extensions would satisfy these rules after such additions or extensions are made.
Group housing.- Planning Norms for Group Housing shall be as below:-
(1) The minimum land or plot area, ground coverage, minimum soft area and such other planning norms for group housing shall be as published by the State Government in the official Gazette.
(2) The coverage and floor area ratio for various densities may be as provided in Table 7 unless otherwise provided in the development plan.
Table 7.
Floor Area Ratio and Coverage for Group Housing
Part VGeneral Building Requirements
Classification of Buildings.- Buildings shall be classified on the basis of occupancy as follows :-
(a) Residential.
(b) Educational.
(c) Institutional.
(e) Business.
(f) Mercantile (Will including both retail and wholesale stores).
(g) Industrial (Will include low, moderate and high fire hazards).
(h) Storage.
(i) Hazardous.
मध्यप्रदेश राजपत्र, दिनांक 13 अपैल 2012
392 (227)
II Open Spaces (within a Plot)
General.- (1) Every room intended for human habitation shall abut on an interior or exterior open space or an open verandah open to such interior or exterior open space.
(2) Open spaces to cater for lighting and ventilation requirement. The open spaces inside or around building have essentially to cater for the lighting and ventilation requirements of the rooms abutting such open spaces and in the case of building abutting streets in the front, rear or sides, the open spaces provided shall be sufficient for the future widening of such streets.
(3) Open spaces separate for each building or wing. The open spaces shall be separate or distinct for each building and where a building has two more wings, each wing shall have separate or distinct open spaces for the purposes of light and ventilation of the wings.
(4) Separation between accessory and main buildings more than 7 meter in height shall not be less than 1.5 meters. For buildings up to 7 meters in height no such separation shall be required.