(1) Sanitation facilities to be provided for occupancies other than Group A1shall be provided in numbers not less than those stipulated in Table 14and Table 15, as the case may be. The occupant load for this purpose shall be computed at the rate given in Table13.
| Sl.No | Occupancy | Built-up area in sq. metres/person |
| 1 | Group A2, B, C,E and F | 5.9 |
| 2 | Group D and J | 1.8 |
| 3 | Group G1 , G2 , H and I | 30 |
Note :—It may be assumed that 2/3 of the number are males and 1/3 are females.
| Sl. No | Fitments | Assembly occupancy and Multiplex complex, | Assembly | Assembly | Assembly |
| Theatres, Auditorium, Art Galleries, Libraries, Restaurants, Wedding halls, Community halls | Bus Terminal | Railway Station | Air ports | ||
| (1) | (2) | (3) | (4a) | (4b) | (4c) |
| 1 | Water Closet | 1 per 200 males or part thereof and 1 per 100 females or part thereof for the first 1000 sq. meters of built up area and 1 per 400 males or part thereof and 1 per 200 females or part thereof for the remaining area. | 4 for first 1000 persons and 1 for every subsequent 1000 persons or part thereof | 5 for first 1000 persons and 1 for every subsequent 1000 persons or part thereof | 5 for first 1000 persons and 1 for every subsequent 1000 persons or part thereof |
| 2 | Urinals | 1 per 50 persons or part thereof for the first 1000 sq. meters of built up area and 1 per 100 persons or part thereof for the remaining area. | 6 for first 1000 persons and 1 for every subsequent 1000 persons or part thereof | 6 for first 1000 persons and 1 for every subsequent 1000 persons or part thereof | 6 for first 1000 persons and 1 for every subsequent 1000 persons or part thereof |
| 3 | Wash Basin | 1 for every 200 males and 1 for every 200 females for the first 1000 sq. meters of built up area and 1 per 400 males and 1 per 400 females or part thereof for the remaining area. | 4 wash basins in each male and female toilet stalls | 4 wash basins in each male and female toilet stalls | 4 wash basins in each male and female toilet stalls |
| 4 | Bath |
| Sl. No | Fitments | Hotels | Storage occupancy | Boarding Institutions/Hostels/Dormitories | Other educational institutions | Office/mercantile occupancies | Industrial occupancy |
|---|---|---|---|---|---|---|---|
| (5) | (6) | (7) | (8) | (9) | (10) | ||
| 1 | Water Closet | 1 per100males and 1 per 100 females | 1 per 50 males and 1 per 25 females | 1 per every 10 boys and 1 per every 8 girls | 1 per every 40 boys and 1 per every 25 girls | 1 for every 25 males or part thereof and 1 for every 15 females or part thereof | 1 per every 25 males and 1 per every 15 females |
| 2 | Urinals | 1 for every25persons or part thereof | 1 per 100 males or part thereof | 1 per every 25 boys | 1 per every 50 boys | 1 for every 25 persons or part thereof | 1 per every 25 persons or part thereof |
| 3 | Wash Basin | 1 for every25persons or part thereof | 1 per every 10 boys and 1 per every 10 girls | 1 per every 40 boys and 1 per every 40 girls | Preferably one on each floor | ||
| 4 | Bath | 1 per100persons | 1 per every 10 boys and 1 per every 10 girls | As required for particular trades or occupancy |
| Sl.No | Fitments | Hospitals with indoor patients ward | Hospitals with outdoor patients | Administration Building | ||
| For males and females | For males | For females | For males personnel | For females personnel | ||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) |
| 1 | Water Closet | One for every 8 beds or part thereof | One for every100 persons or part thereof | Two for every 100 persons or part thereof | One for every 25 persons or part thereof | One for every 15 persons or part thereof |
| 2 | Ablution taps | One in each water closet plus one water tap with draining | One in each water closet. One water tap with draining arrangement shall | One in each water closet. One water tap with draining arrangement shall be provided | ||
| arrange-ment in the vicinity of water closets and urinals for every 50 beds or part thereof | be provided for every 50 persons or part thereof in the vicinity of water closets and urinals | for every 50 persons or part thereof in the vicinity of water closets and urinals | ||
|---|---|---|---|---|
| 3 | Wash Basins | Two up to 30 beds; add one for every additional 30 beds or part thereof | One for every 100 persons or part thereof | One for every 25 persons or part thereof |
| 4 | Baths with shower | One bath with shower for every 8 beds or part thereof | One on each floor | |
| 5 | Bed pan washing sink | One in each ward | ||
| 6 | Cleaners sink | One in each ward minimum | One per floor minimum | One per floor minimum |
| 7 | Kitchen sink and dish washers (where kitchen is provided) | One in each ward minimum | ||
| 8 | Urinals | One for every 50 persons or part thereof | Nil up to 6 persons, 1 for 7-20 persons, 2 for 21-45 persons, 3 for 46-70 persons, 4 for 71-100 persons From 101 to 200 persons add at the rate of 3%. For over 200 persons add at the rate of 2.5%. |
Provided that in the case of Information technology parks / technology parks sanitation requirements shall be that of 75 % of the office occupancy.
(2) The Minimum sanitation facilities to be provided in hazardous buildings shall be as given below:
(a) at the rate of one water closet for the first 50 males or part thereof and two water closet for the first 50 females or part thereof and thereafter one water closet for every additional 70 persons or part thereof, whether male or female;
(b) at the rate of one urinal for every 100 males or part thereof ;
(c) at the rate of one drinking water fountain for every 100 person or part thereof;
(d) at the rate of one washing facility for 50 persons or part thereof; and
(e) In cases where the total number of workers does not exceed 5, at least one water closet shall be provided.