(a) In respect of the following new buildings, special segregated sanitation facilities as separate block shall be provided within the plot, in a conspicuous location, outside the main building block(s):
(i) Civil stations, Municipal offices, Taluk offices, village offices
(ii) Any other office in plots owned by Government or Municipality as decided by the Government or municipality respectively from time to time;
(iii) Hospitals with total built-up area more than 1000 sq. metres;
(iv) Bus stations, railway stations, air ports and public water transport terminals.
(v) Automobile fuel filling stations
(b) Such sanitation facility shall be at least 10 percent of the sanitation requirement stipulated in Tables 14 and 15 for water closets, urinals and wash basins subject to a minimum of one WC, urinal and washbasin each for male, one WC and washbasin each for female and one WC and washbasin each for disabled persons. The minimum standards for WC and Washbasin for disabled shall be as provided in rule 42.
(c) It must be accessible to visitors and general public during the operational hours of the building.
(4) As far as possible, low water consumption plumbing fixtures shall be provided in all buildings.
(5) In the case of Government owned Information Technology Parks, Government approved Private Information Technology Parks, Government approved private Information Technology buildings under Group E occupancy, additional sanitation facilities for visitors need not be provided.