In case of mixed landuse site/ plot, the ground coverage, FAR, setback and other norms shall be in accordance with the zoning plan issued by Competent Authority.
45 [Note: The siting and planning norms for Mixed land use in Transit Oriented Development Zone (as defined in clause xciii-b of Code 1.2) shall be governed by shall be governed by clause 1 of Annexure D and policy notified on 09.02.2016, as amended from time to time.]
(viii) General note: -
(a) The unrestricted height shall only be allowed subject to submission of No Objection Certificate from the appropriate authority (i.e. Defence Establishment, Air Force Establishment, Airport Authority of India, etc.), if any in the area.
Note: It is the responsibility of the competent authority to procure the zoning map/ instructions issued by the appropriate authority (i.e. Defence Establishment, Air Force Establishment, Airport Authority of India, etc.), if any present in its jurisdiction.
(b) The basement may be allowed to the maximum roof height of not more than 1.5 metres from the ground level for the foot print of the building and after that till the zoned area, the roof of basement shall be flush with the ground level.
(c) 46 [The Additional FAR that can be availed by the applicant himself or by the purchaser of TDR Certificate (as defined in clause xciii-a of Code 1.2) shall be governed by clause 3 of Annexure D and policy notified on 16.11.2021, as amended from time to time.]
(d) 47[Electric Vehicle Charging Infrastructure shall be made free from FAR and shall be provided as follows: -
(i) Non-Residential (Shopping complexes, malls, hotels, office spaces etc.) with parking demarcated for at least 10 cars – At least 1 Electric Charging Spots for every 3 parking slots and 100% EV ready with conduits in place for New and Renovated Buildings.
45Inserted/amended vide memo no. Misc-2339-ULB-C/7/5/2006-2TCP dated 18.10.2022.
46Inserted/amended vide memo no. Misc-2339-ULB-C/7/5/2006-2TCP dated 18.10.2022.
47Inserted/amended vide memo no. Misc-720/2024/7/16/2024-TCP dated 25.07.2024 and thereafter substituted vide memo no. MISC-2339(ULB)-Loose/2026/7/15/2026-2TCP dated 05.06.2026.
[54]
(ii) Residential (housing societies run through co-operatives, group housing and those managed through RWAs) with parking demarcated for at least 10 cars – At least 1 Electric Charging Spots for every 5 parking slots and 100% EV ready with conduits in place for New and Renovated Buildings.
The Electric Charging Spots may be provided in basement and/or stilt floors subject to adherence to suitable fire safety and electrical safety norms, to be certified by Fire Department.
Provided that allocation of Electric Charging Spots with regard to parking spaces, as per norms, shall be disclosed at the time of submission of application for grant of Occupation Certificate.
Provided further that in case of existing buildings, if the individual allottee(s) intends to install electrical charging infrastructure for Electric Vehicle(s) in his allocated parking space, then the same may be allowed subject to adherence to suitable electrical safety and fire safety norms, to be certified by the Fire Department as well as concerned DISCOM.]