The plinth of the main building shall be so located with respect to surrounding ground level that proper drainage of the site is assured. The height of the plinth shall not be less than 450 mm and more than 1.5 metres.
(2) The plinth of court-yard shall be at least 150 mm above the level of the street from where entry to plot has been taken and shall be satisfactorily drained.
(3) 58[In no case, any part of the ramp/ steps connecting building plinth to street/ road shall lie on street/ road and obstruct traffic
57Inserted vide memo no. Misc-2339-ULB-C/7/23/2024-2TCP dated 17.12.2024
58Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[62]
movement. However, the ramp/ step from the plot boundary to the entry of house building, if required shall be provided. The minimum slope of such ramp shall be 1:4 with minimum width as 1.0 meter for pedestrian use and 3.0 metres for vehicular use.]
7.4Minimum area, size, height and light and ventilation of different components of Residential premises
(1) Minimum area for a habitable room, kitchen and water closet shall be followed in accordance to tablet given as under:
Sr. no.
Room type
Minimum area (in square metres
Size (minimum width) (in metres)
Minimum Height (in metres)
Light and Ventilation (area of open-able windows, ventilators)
1
Habitable room
9.5
2.4
2.75
Total area not less than 1/8th of the total floor area of the room.
2
Kitchen
5.5
1.8
2.75 (except for the portion accommodate floor trap of above floor)
Total area not less than 1/8th of the total floor area of the room.
3
Pantry
3.00
1.40
2.75
Not applicable
4
Bathroom
1.80
1.20
2.45
5
Water Closet
1.1
0.90
2.45
6
Combined Bath and Water Closet
2.8
1.2
2.45
0.3 square metres on wall not less than 0.3 metres wide.
7
Store
No restriction
No restriction
2.10
Not applicable
10
Garage
14.85
2.75 x 5.40
2.40
11
Doorways Habitable room
Not applicable
0.90
2.10
12
Doorways for kitchen, bath, W.C
Not applicable
0.75
2.00
[63]
59[Note: In case of EWS units, the minimum sizes of bathroom, water closet, and combined bathroom & water closet shall be as follows :-
a) The size of independent water-closet shall be 0.90 m² with minimum width of 0.9 m;
b) The size of independent bathroom shall be 1.20 m² with a minimum width of 1.0 m; and
c) The size of combined bath room and water-closet shall be 1.80 m² with minimum width of 1.0 m.]
(2) Habitable room
(i) In case of Group Housing Scheme the dwelling unit having more than one room may have one of the rooms with a clear floor area not less than 7.5 sq. metres with one side not less than 2.4 metres.
(ii) In case of air-conditioned rooms, the height shall not be less than 2.4 metres measured from the surface of the floor to the lowest point of air conditioning duct or false ceiling; and
(iii) All doors and windows shall open directly or through a verandah or to a permanent open space or an open space abutting the building not less than 1.8 metres in width. No portion of a room shall be assumed to be lighted, if it is more than 3 metres or as stated in National Building Code portion.
(iv) 60[The carpet area of any ‘Store’ or ‘Utility Room’ to be provided in any residential building shall not be more than or equal to the minimum area requirement of a habitable room, i.e. 9.5 sqm;
(v) The dining room, drawing room and dining-cum-drawing room shall be considered as a habitable room;
(vi) The provision of lobby exceeding the size of habitable room, i.e. 9.5 sqm in a residential building shall be allowed subject to prior provision of either a drawing room or dining-cum-drawing room.]
59Inserted vide memo no. Misc-2339-ULB-Vol-I/7/8/2025-2TCP dated 08.12.2025
60Inserted vide memo no. Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[64]
(3) Kitchen
(i) In case there is a separate store, the floor area of the kitchen shall be reduced to 4.5 square metres.
(ii) In case of houses constructed on plots up to 100 square metres, the size of the kitchen shall be reduced to 3.8 square metres.
(iii) The kitchen which is intended for use as a dining space also shall have a floor area of not less than 9.5 square metres with a minimum width of 2.45 metres.
(iv) For the purpose of this regulation, a kitchen shall be deemed to be a habitable room and all the aforementioned requirements regarding ventilation shall apply to it provided that the minimum area of the kitchen shall not be less than 5.5 square metres with a minimum width of 1.8 metres.
(v) In case of Group Housing Scheme the minimum area of the kitchen shall not be less than 5.5 square metres with a minimum width of 1.8 metres.
(4) Bathroom and Water Closet (W.C):
(i) Every bathroom and water closet shall: -
(a) preferably be so situated that at least one of its walls shall have opening for circulation of external air, with provision of exhaust fan.
(b) 61[not be directly over any room other than another W.C, washing place, bath or terrace unless it has a water-tight floor (only in case of toilet fixtures affixed at sunken slab);]
(c) have a platform or seat made of water tight non-absorbent materials;
7.2Courtyard
(1) The courtyard shall have a minimum area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard. Provided that when any room (excluding staircase bay, bathroom and water-closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(2) Provided that such courtyard shall not be less than 12.0 square metres in area and the minimum width of every such courtyard in any direction shall not be less than 3.0 metres. In determining the said aggregate, floor area of the rooms and verandah abutting on the courtyard, following shall be considered:-
(i) Only one half of the floor area of such rooms and verandahs as abut on another courtyard or an open space or road not less than 6 metres in width shall be taken in account;
(ii) The area of the courtyard for the purposes of this Code shall be the area open to sky, clear of all projections.
56 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[61]
57[7.2(a) Podium
(1) Uses permitted shall be for parking of vehicles, fire and building services/ utilities and landscaping/ recreational use on topmost podium slab which is open to sky, subject to provision of parapet wall of maximum 1.6m height, which shall be free from FAR and ground coverage. In addition, toilets and driver’s rest rooms shall be allowed in podium which shall not be counted towards FAR and ground coverage.
(2) Podium may be permitted in a plot of area 1,500 sq.m or more. Podium may be permitted in one or more levels, however, the total height shall not exceed 30 m above ground level which shall be measured upto finished floor level of roof of podium excluding parapet wall of maximum 1.6m height.
(3) Podium shall only be allowed to be constructed in the zoned area. Further, the requirement of ramps for vehicles shall be as specified in National Building Code, as amended from time to time.
(4) If the podium is not accessible by fire tender, then it should not extend more than 11.0 m beyond the building footprint where fire tender access is provided, unless accessible by fire engine. If accessible to a fire tender, a minimum 7.5 m wide ramp with a maximum slope of 1 in 10 shall be required for fire engine access.
Note: - Where this Code is silent regarding any norm, the provisions of National Building Code, as amended from time to time, shall be followed.]
7.5Boundary Wall, Fence, Gate and Porch
(1) The location of gate/ gates shall be as per zoning plan.
(2) Maximum permissible height of front side boundary wall shall be not more than 1.2 metres from the mean level of abutting street in front of the plot from where entry to the plot has been taken.
Note: The owner/ applicant if desires, is permitted to not construct boundary wall in front of plot, so that the said area can be utilized for parking.
(3) Maximum height of boundary wall at rear and side of plot shall not be more than 1.8 metres from the mean level of abutting street in front of the plot from where entry to the plot has been taken.
Note: In case of plots above 2000 square metres, maximum height of boundary wall at the rear and side of plot shall not be more than 1.8 metres from the abutting ground level.
(4) A railing/ grill with or without poly carbonate/ fibre glass sheet covering of 0.75 metre height shall be permitted over and above the maximum height of boundary wall at all sides.
62 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[66]
(5) The temporary porches of polycarbonate sheets/ fibre glass roof or any other temporary material covering on suitable structure, shall be allowed in residential plots with the condition that these shall be open on sides in the driveway area within the plot.
(6) The provisions of above Code 7.5(2), (3), (4) and (5) are not applicable to boundary walls of jails.
(7) Boundary wall upto the height of 2.4 metres may be permitted by the Competent Authority in industrial buildings, electric substations, transformer stations, institutional buildings like hospitals, industrial buildings like workshops, factories and educational buildings like schools, colleges, including hostels and other uses of public utility undertakings and strategically sensitive buildings.
(d) preferably be enclosed by walls and partitions and the surface of every such walls or partition, shall be finished with a smooth impervious material to a height not less than 1.5 metres above the floor of such room; and
(e) Be provided with impervious floor covering sloping towards the drain with a suitable gradient and not towards verandah or any other room.
61 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[65]
(ii) 62 [Where the water-closet room in a building is not connected to exterior, it shall be ventilated by mechanical means or through a vertical shaft open to sky of a minimum size stated at Code 7.11(6) for ventilation to toilet, bath and water closet, but it shall be counted towards covered area.]
(iii) No room containing water-closet shall be used for any other purposes except as lavatory and no such room shall open directly into any kitchen or cooking space by a door/ window or another opening. Every room containing watercloset shall have a door completely closing the entrance to it.
(iv) Soil or ventilating pipes shall not be allowed on the exterior face of any building, provided these shall either be embedded in the walls or pipe ducts to be provided to accommodate them.
(v) Security rooms each measuring maximum area of 3.0 square metres is permitted only at the entry and exit gates of premises.
7.6Staircase
(1) Every building intended to be used as multiple residential building or commercial or educational and institutional or industrial building shall be provided with required number of staircases (accessible from a maximum distance of 30 metres (45 metres, if building has automatic sprinklers for firefighting) from any part of the building, extending from ground floor level to the highest floor, having following specifications:
Sr. no.
Type of building
Minimum permissible clear width of staircase (in metres)
Minimum permissible width of tread (in metres)
Maximum permissible height of riser (in metres)
1
63[Residential
Upto 16.5 metres height (residential plotted)
0.9
0.25 (without nosing)
0.19]
Other than residential plotted
1.2
2
Commercial
Plots upto 50 square metres area
0.9
0.30 (without nosing)
0.15
Plots above 51 square metres area
1.2
63Substituted vide memo no. Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[67]
3
Assembly building
2.0
0.30 (without nosing)
0.15
4
Educational building
1.5
0.30 (without nosing)
0.15
5
Institutional building
2.0
0.30 (without nosing)
0.15
6
Inland Container Depot & Custom bounded area
1.5
0.30 (without nosing)
0.15
7
Industrial building;
1.5
0.30 (without nosing)
0.15
8
Any other buildings
1.5
0.30 (without nosing)
0.15
(2) The minimum head-room in a passage under the landing of a staircase shall be 2.1 metres. The minimum clear head-room in any staircase shall be 2.1 metres.
(3) The maximum numbers of risers in single flight are limited to 14.
(4) If a service or a spiral staircase is provided, its width shall not be less than 1.0 metre and its average tread width shall not be less than mention in table of sub-Code (1).
(5) Notwithstanding anything contained in sub-Code (1), the staircases in the private portion of a public building and industrial building not open to the general public, may be of the sizes mentioned for residential building.
(6) For residential plot sizes upto 100 square metres, there is no restriction for maximum permissible height of riser, subject to the condition that it shall not cause inconvenience to user.
7.7Ramps and Lifts
(1) Every building having more than 15 metres height shall be provided with a lift or a ramp with an inclination of 1:10 in addition to the staircases.In all residential building having more than 15 metres height, lift is mandatory to install in numbers depending on the occupancy of building.
(2) 64[In case of public building with only ground floor, ramp shall be provided for differently abled persons reaching its plinth level. Further, in case of public building more than one storey lift or ramp shall be provided, but at ground floor, ramp shall be provided for reaching plinth level of building.]
(3) Ramps:
(i) The ramp to basement and parking floors shall not be less than 7.2 metres wide for two-way traffic and 4 metres wide
64 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[68]
for one-way traffic, provided with minimum gradient of 1:10.
(ii) 65[The minimum width of the ramps in hospitals shall be 2.4 metres for movement of stretcher and for public use. In no case, the hospital ramps shall be used for vehicular movement.]
(iii) Ramps may also be provided in the setbacks which can be sloped considering unhindered movement of fire engine and in no case the gradient shall be less than 1:10. (to be read with basement)
(iv) All structural design/safety aspects as per latest Bureau of Indian Standards Codes and National Building Code, 2005 (as amended from time to time) shall be complied along with consideration of weight of Fire Engine & its manoeuvring.
(v) 66[XXXX].
(vi) A ramp shall have handrail on at least one side, and preferably two sides with minimum height of 0.90 metres, measured from the surface of the ramp. The handrails shall be smooth and extend to 0.30 metres beyond the top and bottom of the ramp. Where major traffic is predominantly children, the extra handrail shall be placed 0.76 metre height.
(4) Where ramps with gradients are necessary or desired, they shall conform to the following requirements:
A ramp when provided shall not have a slope greater than 1:20 or maximum of 1:12 for short distance up to 9 metres.
(5) Lifts: -
Wherever lift is required as per Code, provision of at least one lift shall be made for the wheel chair users, with the following cage dimensions, recommended for passenger lift of 13 persons capacity by the Bureau of Indian Standards:-
· Clear internal depth 1.1 metres.
· Clear internal width 2.0 metres.
· Entrance door width 0.9 metre.
(i) a handrail not less than0.6-metre-long and 1 metre above floor level shall be fixed adjacent to the control panel.
65 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
66 Deleted vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[69]
(ii) the minimum size of lift lobby shall be 1.8 metres x 2.0 metres or more.
(iii) the interior of the cage shall be provided with Braille symbols and auditor signage that audibly indicates the floor. When the cage reached on floor, it shall indicate that the door of the cage for entrance/ exit is either open or closed.
Chapter 7
7.1 Parking
(1) 52[For plots situated in residential plotted colony,
Sr. no.
Size of plot
No of ECS
1
500 Sq.mt. and above
2 ECS per Floor in stilt/open within the plot.
2
250 Sq.mt. and upto 500 Sq.mt
1.5 ECS per Floor in stilt/open within the plot.
3
100 Sq.mt. and upto 250 Sq.mt.
1 ECS per Floor in stilt/open within the plot.
4
Upto 100 Sq.mt.
0.5 ECS per Floor in stilt/open within the plot.
Note- (a) One ECS = 12.5 sq. mt. to be indicated in Car bay size of 2.5 mtrX 5 mtr in residential plots only. (b) Stilt parking shall be mandatory upon construction of 3rd / 4th floors in town falling under Hyper potential category (Gurugram Manesar Urban Complex). For other towns in the State, stilt parking shall be mandatory upon construction of 4th floor. This shall be with prospective effect, for the approval of building plans for all new constructions on vacant plots or when a plot is proposed to be reconstructed upon de novo.] 53 [(c) A service/guard room and a toilet (maximum 16 sqmt. for plots upto 200 sqmt. and 20 sqmt. for plots above 200 sqmt.) shall be permissible in the stilt area/floor, subject to conditions that this area be located adjacent to the staircase/ lift, be counted towards FAR and that the parking and other norms are fulfilled.]
(2) 54 [In Group Housing, minimum 1.5 Equivalent Car Space (ECS) for each dwelling unit shall be required. In addition to above parking requirement for main dwelling units, additional 5% of the total car parking shall be made available against EWS category flats adjoining or below the EWS category flats.]
(3) 55[In Integrated/ Multi Storey Commercial Building, Big Box Retail Stores, restaurant, multiplex/ cinema/ theatre and shopping mall 1.0 ECS for every 50 square metres of covered area shall be required.
52Substituted vide memo no. Misc-2339-VOL-III-ULB/7/5/2006-2TCP dated 27.05.2020 and shall be implementable from date of issuance of said memo..
53 Inserted vide memo no. Misc-2339-ULB-VOL-II-A/7/5/2006-2TCP dated 19.01.2022.
54Substituted vide memo no. Misc-2339-ULB-Vol-I/7/20/2024-2TCP dated 06.11.2024
55 Substittued vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[59]
(4) In offices, Cyber Park/ IT Park/ Cyber Cities, 1.0 ECS for every 75 square metres of covered area shall be required.
(5) In shopping area and designated shopping markets being developed by competent authority, 65% of total site area shall be kept for parking purpose.
(6) In hospital, parking is to be provided as 1.0 ECS for every 2 beds and visitors parking as 1 ECS for every 4 beds.
(7) For industries, 1.0 ECS for every 300 square metres of covered area shall be provided.
(8) For Assembly buildings (i.e. stand-alone theatres, cinema houses, concert halls, auditoria and assembly halls), 1 ECS for every 40 square metres of covered area shall be provided.
(9) For primary and secondary schools, 15% of total site area shall be provided for parking purpose.
(10) For College, parking at rate of 1 ECS for every 200 square metres of covered area shall be provided.
(11) For Government or semi-public offices including Civil/ High Court, 1 ECS for every 75 square metres of covered area shall be provided.
(12) For hotels and Motels, 1.0 ECS for every 75 square metres of covered area.
(13) The covered parking in the basement or in the form of multi-level parking above ground level or stilt shall not be counted towards Floor Area Ratio (FAR). However, the footprint of separate parking building blocks shall be counted towards ground coverage.
(14) In case of provision of mechanical parking in the basement floor/ upper stories, the floor to ceiling clear height of the basement/ floor may be maximum of 4.75 metres.
(15) No storage and commercial activities shall be permitted in the covered parking areas.
(16) The misuse of the covered parking space shall immediately attract levy of three times the penalty of the composition fee prescribed for the excess covered area in the respective category.
[60]
Note [applicable for sr. no. I (2) to (16)]:
1ECS = 23 square metres for open parking, 28 square metres for parking on stilts and 32 square metres for basement parking.]
7.1a 56[Party wall
(1) In case the plot holder intends to construct a common boundary wall with minimum width of 230mm, he/ she shall be required to submit consent of owners of adjacent plots with which his/ her plot shares a common boundary i.e. the plot on both sides and rear.
(2) Wherever the plot holder opts for independent boundary wall within his/ her plot boundary:
(i) Independent boundary wall shall be allowed only where adjacent plots are vacant.
(ii) The owner shall ensure that no part of foundation and boundary wall is constructed on the adjoining plot.]