13.1.1 Boundary Wall Compound Wall and Gate
1 The maximum height of the boundary wall / compound wall is given in Table No.13.1.
2 For building units at junction of roads, a grill fence shall be provided with the following provisions:
a) At least 50% perforation in the grill.
b) The base of the grill fence shall not exceed 0.8 m from the level of the crown of the adjacent road for a length of 9 m from the corner of the building unit at the junction.
3 Boundary gate shall not open outward and shall be provided with a means to prevent the gate from opening outward on the pavement or road.
4 The minimum width of a boundary gate for all uses except Dwelling 1 and 2 shall be 6 m.
5 For building unit at junction of roads, the following shall be applicable:
a) A gate shall not be permitted on the corner of the of the boundary wall.
b) If the adjacent road width is equal or more than 12 m, the opening in the boundary wall shall be located at a minimum distance of 15 m from the corner of the building unit at the junction. If the length of the building unit on the roadside is less than 15 m, the opening in the boundary wall shall be provided at the farthest end from the junction.
Table No. 13:1 Maximum Permissible Height of Boundary Wall / Compound Wall for all Buildings
| No | Use | Maximum Height from crown of the Adjacent Road (m) | |
| Roadside | Other than adjacent road / roadside or all other side of building-unit | ||
| (1) | (2) | (3) | (4) |
| 1 | Other than Industrial | 1.5* | 1.8 |
| 2 | Industrial | 3 | 3 |
Note: * Boundary wall of more than 1.5 m may be allowed with permission (Refer Figure No. 13.1).

Figure No. 13.1: Boundary Wall / Compound Wall for Building