For the purpose of calculating FAR, cantilevered, permitted roof projections, lift room, mumty, balcony, basement or any floor if used for parking, services and storage, stilt area (unenclosed) proposed to be used for parking/ pedestrian plaza only, open staircase (without mumty), terrace with or without access, fire staircase, water tank, open courtyard of permitted size shall not be counted towards FAR:
Provided, area under atrium, shaft, chutes, lift well and staircase from stilt to next floor shall be counted towards FAR only at once on ground floor:
Provided in case the ventilation shaft area is more than 3 square meter, it shall not be counted in FAR.
- “Frame Control Drawing” shall mean the numbered sheet of drawing signed by the Chief Administrator and kept in his office defining boundaries of building plots, compulsory building lines, permissible heights of
buildings to be realised in prescribed stages, site and floor coverage, restrictions on treatment of external facades including the permissible sizes of openings and such other restrictions on the development of sites as may be prescribed.
-
“Front” as applied to a building shall mean general the portion facing the street from which it has access and incase of doubt as determined by the chief administrator.
-
“‘Gallery” shall mean a raised floor constructed within the height of the single storey.
-
“Garage” shall mean a building or portion thereof, used for shelter, storage, or repair of a wheeled vehicle
-
“Ground Coverage” means built up area covered at ground level: For the purpose of calculating ground coverage area under shaft, chute, lift well, atrium and staircase shall be counted towards ground coverage: Provided ventilation shaft area more than 3 square meters, fire staircase and open courtyard of permitted size, shall not be counted in ground coverage;.
-
“Group Housing” means a building designed and developed in the form of flats for residential purpose or any building ancillary to group housing;
-
“Habitable room” A room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is used as a living room, but not including bathrooms, water-closet compartments, laundries, serving and store pantries, corridors, cellars, attics, and spaces that are not used frequently or during extended period.
-
“Height” as applied to a building shall mean the vertical measurement of the building measured from the finished level of the centre of the street where such street exists, or from the mean level of the ground adjoining the outside of the external walls to half the height of the roof in the case of sloping roofs and to the highest level of the building in the case of buildings with flat roofs excluding the projected portions of mumties, flues, ducts, minarets and parapets not exceeding three feet six inches in height and as applied to a room shall mean the vertical measurement from the upper surface of the floor to the under surface of the ceiling of the same room joist and beams being allowed to project beneath the ceiling; and in the case of a shaped or sloping ceiling, the height shall be the mean height of any such room.
-
“Layout plan” means a plan of the entire site showing location of plots/ building blocks, roads, open spaces, entry/ exit, parking, landscaping etc. indicating activity of all land.
-
“Loft” shall mean an intermediate space between two floors on a residual space with maximum height of 1.5 metres and which is constructed or adopted for storage purposes only.
-
“Licensed Plumber”shall mean a person registered by the Chief Administrator for the purpose of these rule.
-
“Lobby”- means a covered space in which all the adjoining rooms open.
-
“Lower Ground floor”- shall mean a floor which is more than half of its height above the mean ground level and rest of the height below the mean ground level.
-
“Mumty” shall mean a small structure erected on the roof of a building at the head of a staircase to protect such staircase from weather.
-
“Mezzanine floor” shall mean an intermediate floor between two floors of any storey forming an integral part of floor below.
-
“Mean level of street” means the average level of all points on the surface of the street from which the site derives its access measured at the centre line of street;
-
"Non-nuisance professional consultancy services" shall include Doctors (without nursing home), Lawyers, Architects & Town Planners (without studio), Chartered Accountants, Company Secretaries only.
-
“Occupancy” means the main purpose for which a building or a part of building is used or intended to be used;
-
“Open space” means a space forming an integral part of the plot left open to sky;
-
“Owner”-Person or body having a legal interest in land and/or building thereon. This includes free holders, leaseholders or those holding a sub-lease which both bestows a legal right to occupation and gives rise to liabilities in respect of safety or building condition. In case of lease or sub-lease holders, as far as ownership with respect to the structure is concerned, the structure of a flat or structure on a plot belongs to the allottee/ lessee till the allotment/lease subsists.
-
“Parapet” means a low wall built along the edge of a roof or a floor, ramp, staircase, balcony have Min.1.0 m & max.1.2 m in height.
-
“Parking” means a space enclosed or unenclosed, to park vehicles together with a driveway connecting the parking space with a street permitting ingress and egress of the vehicles;
-
“Partition” means a wall which bears no load other than its own weight;
-
“Party Wall” shall mean a wall partly constructed on one plot of land, and partly on an adjoining plot and serving both structurally.
-
Plinth Area”- The built up covered area measured at the floor level of the basement or of any storey.
-
'Plinth height' shall mean the height of the ground floor above the street level measured from the level of the centre of the adjoining street.
-
“Plinth Level” The portion of a structure between the surface of the surrounding ground and surface of the floor, immediately above the ground from the centre of the front access road.
-
“Plot” means piece of land or site enclosed by definite boundaries;
-
“Plotted Development” – Type of development layout wherein a stretch of developed land is divided into regular sized plots for uniform controlled building volumes.
-
“Porch” means a covered surface supported on pillars or otherwise for the purpose of pedestrian or vehicular approach to a building.
-
“Powder Room” shall mean a room or a space in which soil pan and a wash basin shall be accommodated so constructed to allow free circulation of air throughout the room.
-
“Rain Water Pipe” shall mean a pipe or drain situated wholly above ground and used or constructed to be used solely for carrying off rain water directly from roof surfaces.
-
“Rear” as applied to a building shall mean that portion which is on the opposite of 'Front'.
-
“Sector” shall mean a sector of the Master Plan of Chandigarh.
-
“Self-certification” means seeking approval of building plans duly prepared and certified by Architect as per relevant building Rule, zoning plan and as per parameters/ policies issued by the Competent Authority from time to time;
-
“Service floor” means the floor of a building with maximum height of 2.4 metres, where service equipment, utility lines and various machinery are located;
-
Service zone” means a zone on the terrace for services related to building.
-
“Service Road”- A road/lane provided at the front, rear or side of a plot for service purpose.
-
“Setback” means a line usually parallel to the plot boundary as laid down in each case by the Competent Authority beyond which nothing can be constructed towards the plot boundary unless specifically allowed by Competent Authority;
-
“Sewage Drain” shall mean a drain for conveying solid or liquid filth and waste liquids, such conduit or pipe being the property of or vested in the Government or public authority responsible for the disposal of such sewage.
-
“Site Plan” a detailed plan showing the proposed placement of structures, parking areas, open space, landscaping and other development features, on a parcel of land, as required by specific sections of the development code.
-
“Special Area” shall mean the areas shown as such on the zoning plans in which Architectural Control Sheets shall apply.
-
“Storey” shall mean any horizontal division of a building so constructed as to be capable of use as a living apartment, although such horizontal division may not extend over the whole depth or width of the building but shall not include mezzanine floor.
-
“Stilt” means poles, posts or pillars or columns used to allow a structure or building to stand at a distance above the ground and which is of non habitable height.
-
“Storm Water Drain” or Rain Water Drain’ shall mean a drain used or constructed to be used solely for conveying to any sewer (either directly or through another drain) any rain water of roofs or grounds surfaces either paved or unpaved but shall not include a rain water pipe.
-
“Street” shall mean any road, footway, square court, alley, or passage accessible whether permanently or temporarily to the public, and whether a thoroughfare or not and shall include every vacant space, notwithstanding that it may be private property and partly or wholly obstructed by any gate, post, chain or other barrier whether of houses, shops or other building abutting thereon, which is used by any person as means to access to or from any public place or thoroughfare, whether such persons be occupiers of such buildings or not , but shall not include any part of such space which the occupier of any such building has a
right at all hours to prevent all other persons from using as aforesaid, and it shall include also the drains or gutters therein, or on either side and the land, whether covered or not by any pavement, verandah or other erection, upto the boundary of any abutting property not accessible to the public.
- "Structural Engineer" means a person who is a post graduate in structural engineering from a recognized Indian or Foreign University or Corporate Member of Civil Engineering Division of the Institute of Engineers of India or equivalent Institute with a minimum of three years’ experience in structural engineering practice in designing structures and field work and/ or registered as such with the Competent Authority, employed for preparation of structural design of buildings upto 15 metres height. However, only the Structural Engineer Possessing post graduate qualification in structural engineering along with a minimum of 3 years’ experience
in the design of multi storey and specialized structure and/ or registered with Competent Authority shall be employed to undertake and submit the structural design of buildings other than residential and commercial buildings upto 15 metres height (including stilt), as per the requirements of the relevant forms.
-
“Structural Wall” shall mean a load bearing wall or a wall that carries load in addition to its own load.
-
“Sub-soil Drain” shall mean a drain used or constructed to be used solely for conveying to any sewer (either directly or through another drain) any water that may percolate through the sub-soil.
-
“Sun-shade” means a slope or horizontal or vertical structure over hanging, usually provided over openings on external wall to provide protection from sun and rain and shall not be used for human habitation;
-
“Temporary Building” shall mean a building built of un burnt bricks, burnt bricks without mortar, corrugated iron, metal or MS frame, bamboo, thatch, wood boarding or plywood but shall not include a building built of burnt bricks, cement blocks or stones laid in mortar and such structure can be dismantled or relocated.
-
“Un-authorised Construction”- means the erection or re-erection, addition or alternations which is not approved or sanctioned by the Authority.
-
“Underground/Overhead Tank”- An installation constructed or placed for storage of water.
-
“Ventilation”- Supply of outside air into, or the removal of inside air from an enclosed space.
a. Natural Ventilation - Supply of outside air into a building through window or other openings due to wind outside and convection effects arising from temperature or vapour pressure differences (or both) between inside and outside of the building.
b. Positive Ventilation - the supply of outside air by means of a mechanical device, such as a fan.
c. Mechanical Ventilation - Supply of outside air either by positive ventilation or by infiltration by reduction of pressure inside due to exhaust of air, or by a combination of positive ventilation and exhaust of air.
-
“Verandah” means a covered area with at least one side open to the outside with the exception of1.2 metre high parapet on the upper floors to be provided on the open side. Min. 1 metre and max. 1.2 m. high parapet wall.;
-
“Water-borne Sanitary Installations” shall mean any urinal, latrine, water closet apparatus, bidet, slop sink, hospital sanitary fittings, such as, bed pan and urine bottle sink or other similar fittings, the solid or liquid filth from which is intended to be discharged by a flush of water, and shall include all manholes, traps, gullies, soil pipes, waste pipes, ventilating pipes, anti-syphonage pipes and drains communicating with sewers.
-
“Water closet room” shall mean a room which contains a soil pan and shall also include any room which is partitioned or divided into two or more cubicles each containing a soil-pan if the partitions or divisions are so constructed as to allow the free circulation of air throughout the room.
-
“Zoning Plan” shall mean the numbered plan signed by the Chief Administrator and kept in his office defining the layout of any numbered sector/ pocket of the Master plan of Chandigarh showing the streets, boundaries of building plots, open spaces, position of protected trees or other features, and showing in colour or by other means the specified land-use, building lines, permissible heights of buildings, site coverage and such other restrictions on the development of land or buildings as may be prescribed, provided such plans can also be prepared for individual buildings and stand alone sites.
4 RESIDENTIAL USE
4.1 Residential (PLOTTED)
| Sr. No. | PARAMETERS | MARLA | ONE KANAL | TWO KANAL | ABOVE TWO KANAL |
| 1 | Set Backs | As per Zoning/ Frame Control | |||
| 2 | Ground Coverage (max.) | 65% + Upto 5% | 50% | 45% | 35% |
| 3 | FAR (max.) | 2.0 | 1.5 | 1.25 | 1.0 |
| 4 | Plinth | Minimum 0.3m (1'-0") | Minimum 0.3m (1'-0") Maximum 1.2 (4'-0") | ||
| 5 | Height (maximum) | Phase-I:10.06m(33'-0")Phase-II:9.83m(32'-3"), Rear Court Yard: 3.35m (11'-0")From the plinth level. | Main building 10.67m (35'-0") & Rear Court Yard 3.35 m (11'-0") from 0.30m (1'-0") plinth height. | ||
| 6 | No. of Storeys | 3 (Three) | |||
| 7 | Habitable Room | Min. Area 9.50 Sq. m (100 Sq. Ft.) with Min. Width 2.40 m (8'-0") & Min. Height 2.75m (9'-0") below the ceiling/ false ceiling or A.C. duct and below the beam 2.4m (8'-0"). | |||
| 8 | Kitchen | Min. Area 4.50 Sq. m (49 Sq. Ft.) with Min. Width 1.50 m(5'-0") & Min. Height 2.75 m (9'-0") | |||
| 9 | Toilet | Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6"). | |||
| 10 | WC & Powder room | Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min.Height 2.29m(7'-6") | |||
| 11 | Bath | Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | |||
| 12 | Light & Ventilation | Minimum 1/8th of the floor area of the habitable space. Window/ Vent size in WC/ Bath/ Toilet shall be min. 0.3 Sq. m of the area with side not less than 0.30 m (1'-0"). | |||
| 13 | Ventilation Shaft | Minimum area 1.2 sq. m (13sq. ft.) with minimum width 0.90 m (3 ft.) | |||
| 14 | Interior Courtyard For light & ventilation | Minimum area 9.0 sq. m with minimum 3.0 m width | |||
| 15 | Verandah for light | Minimum width 1.8m (6'-0") and depth not more than 3.66 m (12'-0"). | |||
Page | 12