| Sr. No. | PARAMETERS | NORMS | ||
| 1. | Permissible FAR | Maximum / Additional F.A.R. upto 50% of the minimum F.A.R. shall be allowed/ permitted within the same height as under after the payment of conversion charges already fixed under the scheme. | ||
| Plot Area | Minimum FAR allowed | Maximum FAR achieved after allowing 50% of the minimum FAR for calculation of conversion | ||
| Upto 1 Acre | 2.00 | 3.00 | ||
| Above 1 Acre | 1.75 | 2.625 | ||
| At least 20% of the available FAR shall be used for public space which includes circulation areas and toilets. | ||||
| 2. | Seating capacity | Total seating capacity of the theatre shall not be more than that of existing Cinemas Theatres and it shall not be less than 75% of the sanctioned seating capacity | ||
| 3. | Commercial area | Allowed up to the area under the cinema halls and projection rooms. If any existing cinema site has some Commercial area as a part of the original plan, the same shall be allowed over and above the commercial area allowed under this rule. | ||
| 4. | Height (max.) | As per the Architectural Control Drawing applicable to the site or as per order of the Chandigarh Administration. | ||
| 5 | Toilet | Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | ||
| 6 | WC and Powder room | Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6") | ||
| 7 | Bath | Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6") | ||
| 8 | Staircase | Minimum width 2.0m Minimum Tread 0.30 m (12"), Maximum Riser 0.15 m (6") With a minimum clear height 2.4 m (8'-0") Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). | ||
| 9 | Lift | Mandatory | ||
| 10 | Mumty | Allowed | ||
| 11 | Services on terrace | Solar Water heating System, Solar Photo voltaic Power Plant, Water Tank and cooling towers for air conditioning plant, mumty, machine room, Screen Wall to encase the services etc. within the service zone. | ||
Page | 28
| Sr. No. | PARAMETERS | NORMS |
|---|---|---|
| 12 | Basement | Compulsory (single level). Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R. |
| 13 | Ramp | Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12. |
| 14 | Parking | 3 ECS for per 100 sq m Of the covered area in respect of multiplex or cinema component + 30% of the total covered area of that component i.e. multiplex or cinema and 2 ECS per 100 sqm of the balance total commercial covered area including circulation area. Minimum 80% of the parking should be proposed underground to keep more open/ green area on surface. |
| 15 | Rain Water Harvesting System | Compulsory of adequate capacity. |
| 16 | Solar Water Heating System | Compulsory of adequate capacity. |
| 17 | Solar Photo Voltaic (Compulsory) | i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak Or 5% of connected load, Whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak Or 3% of connected load, Whichever is higher. |
| 18 | Flushing System | Dual flushing system of not more than 7 Ltr. Capacity per W.C. |
| 19 | Parapet/ Railing | Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty. |
| 20 | Minimum Passage/ Corridor | Number of users up to 100 ... 2.0 m (6'-6") Number of users 101 and above ... 2.40 m (8'-0") Minimum height 2.40 m (8'-0") |
| 21 | Amalgamation/Fragmentation | Not allowed |
Note:-
upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read alongwith the chapter on Miscellaneous Building Requirements & other chapters.