3.1 Classification of Buildings Based on Occupancy
3.1.1 General Classification
All buildings, whether existing or hereafter erected shall be classified according to use or the character of
occupancy in one of the following groups:
| Group A | Residential |
|---|---|
| Group B | Educational |
| Group C | Institutional |
| Group D | Assembly |
| Group E | Business |
| Group F | Mercantile |
| Group G | Industrial |
| Group H | Storage |
| Group J | Hazardous |
The details of each occupancy and example of buildings in each group are given in 3.1.2 to 3.1.10.
3.1.1.1 Minor occupancy
This is purely incidental to operations in a main occupancy, which shall be considered as part of the main occupancy and shall be classified under the relevant group for the main occupancy.
3.1.1.2 Mixed occupancy
Where two or more types of occupancies intermingle in the same building, the entire building shall be treated as mixed occupancy and the same shall comply with 3.1.12.
3.1.2 Group A Residential Buildings
These shall include any building in which sleeping accommodation is provided for normal residential purposes with or without cooking or dining or both facilities, except any building classified under Group C.
Buildings and structures under Group A shall be further subdivided as follows:
Subdivision A-1 Lodging and rooming houses
Subdivision A-2 One or two family private dwellings
Subdivision A-3 Dormitories
Subdivision A-4 Apartment houses
Subdivision A-5 Hotels
Subdivision A-6 Starred hotels
a) Subdivision A-1 Lodging and rooming houses — These shall include any building or group of buildings under the same management, in which separate sleeping accommodation on transient or permanent basis, with or without dining facilities but without cooking facilities for individuals is provided. This includes inns, clubs, motels and guest houses.
NOTE — A lodging or rooming house shall be classified as a dwelling in Subdivision A-2, if no room in any of its private dwelling units is rented to more than three persons.
b) Subdivision A-2 One or two family private dwellings — These shall include any private dwelling, which is occupied by members of one or two families and has a total sleeping accommodation for not more than 20 persons.
If rooms in a private dwelling are rented to outsiders, these shall be for accommodating not more than three persons per room.
If sleeping accommodation for more than 20 persons is provided in any one residential building, it shall be classified as a building in Subdivision A-1 or Subdivision A-4 as the case may be.
c) Subdivision A-3 Dormitories — These shall include any building in which group sleeping accommodation is provided, with or without dining facilities for persons who are not members of the same family, in one room or a series of closely associated rooms under joint occupancy and single management, for example, school and college dormitories, students, and other hostels and military barracks.
d) Subdivision A-4 Apartment houses — These shall include any building or structure in which living quarters are provided for three or more families, living independently of each other and with independent cooking facilities, for example, apartment houses, mansions and Chawls.
e) Subdivision A-5 Hotels — These shall include any building or group of buildings under single management, in which sleeping accommodation is provided, with or without dining facilities for hotels classified up to Four Star Category.
f) Subdivision A-6 Starred hotels — These shall include the hotels duly approved by the concerned authorities as Five Star and above hotels.
3.1.3 Group B Educational Buildings
These shall include any building used for school, college, other training institutions involving assembly for instruction, education or recreation for not less than 20 students.
Buildings and structures under Group B shall be further subdivided as follows:
Subdivision B-1 Schools up to senior secondary level
Subdivision B-2 All others/training institutions
a) Subdivision B-1 Schools up to senior secondary level — This subdivision shall
include any building or a group of buildings under single management which is used for students not less than 20 in number.
b) Subdivision B-2 All others/training institutions — This subdivision shall include any building or a group of buildings under single management which is used for students not less than 100 in number.
In the case of temporary buildings/structures which are utilized for educational purposes, the provisions of 3.2.5.3 shall apply.
If residential accommodation is provided in the schools/institutions that portion of occupancy shall be classified as a building in Subdivision A-3.
3.1.4 Group C Institutional Buildings
These shall include any building or part thereof, which is used for purposes, such as medical or other treatment or care of persons suffering from physical or mental illness, disease or infirmity; care of infants, convalescents or aged persons and for penal or correctional detention in which the liberty of the inmates is restricted. Institutional buildings ordinarily provide sleeping accommodation for the occupants.
Buildings and structures under Group C shall be further subdivided as follows:
Subdivision C-1 Hospitals and sanatoria
Subdivision C-2 Custodial institutions
Subdivision C-3 Penal and mental institutions
a) Subdivision C-1 Hospitals and sanatoria — This subdivision shall include any building or a group of buildings under single management, which is used for housing persons suffering from physical limitations because of health or age and those incapable of self-preservation, for example, hospitals, infirmaries, sanatoria and nursing homes.
b) Subdivision C-2 Custodial institutions — This subdivision shall include any building or a group of buildings under single management, which is used for the custody and care of persons, such as children, convalescents and the aged who are incapable of self-preservation, for example, homes for the aged and infirm, convalescent homes and orphanages.
c) Subdivision C-3 Penal and mental institutions — This subdivision shall include any building or a group of buildings under single management, which is used for housing persons under restraint, or who are detained for penal or corrective purposes, in which the liberty of the inmates is restricted, for
example, jails, prisons, mental hospitals, mental sanatoria and reformatories.
3.1.5 Group D Assembly Buildings
These shall include any building or part of a building, where not less than 50 persons congregate or gather for amusement, recreation, social, religious, patriotic, civil, travel and similar purposes, for example, theatres; motion picture houses; assembly halls; auditoria; exhibition halls; museums; skating rinks; gymnasiums; restaurants; places of worship; dance halls; club rooms; passenger stations and terminals of air, surface and marine public transportation services; and stadia.
Buildings under Group D shall be further subdivided as follows:
Subdivision D-1 Buildings having a theatrical or motion picture or any other stage and fixed seats for over 1 000 persons
Subdivision D-2 Buildings having a theatrical or motion picture or any other stage and fixed seats up to 1 000 persons
Subdivision D-3 Buildings without a permanent stage having accommodation for 300 or more persons but no permanent seating arrangement
Subdivision D-4 Buildings without a permanent stage having accommodation for less than 300 persons with no permanent seating arrangement
Subdivision D-5 All other structures including temporary structures designed for assembly of people not covered by Subdivisions D-1 to D-4, at ground level
Subdivision D-6 Buildings having mixed occupancies of assembly and mercantile (for example, shopping malls providing facilities such as shopping, cinema theatres, multiplexes and restaurants/food courts)
Subdivision D-7 Underground and elevated mass rapid transit system
a) Subdivision D-1 — This subdivision shall include any building primarily meant for theatrical or operatic performances and which has a stage, proscenium curtain, fixed or portable scenery or scenery loft, lights, mechanical appliances or other theatrical
accessories and equipment for example, theatres, motion picture houses, auditoria, concert halls, television and radio studios admitting an audience and which are provided with fixed seats for over 1 000 persons.
b) Subdivision D-2 — This subdivision shall include any building primarily meant for use as described for Subdivision D-1, but with fixed seats up to 1 000 persons.
c) Subdivision D-3 — This subdivision shall include any building, its lobbies, rooms and other spaces connected thereto, primarily intended for assembly of people, but which has no theatrical stage or permanent theatrical and/or cinematographic accessories and has accommodation for 300 persons or more, for example, dance halls, night clubs, halls for incidental picture shows, dramatic, theatrical or educational presentation, lectures or other similar purposes having no theatrical stage except a raised platform and used without permanent seating arrangement; art galleries, community halls, marriage halls, places of worship, museums, lecture halls, passenger terminals and heritage and archaeological monuments, pool and billiard parlours, bowling alleys, community halls, courtrooms, gymnasiums (without spectator seating), indoor swimming pools (without spectator seating), indoor tennis courts (without spectator seating).
3.1.6 Group E Business Buildings
These shall include any building or part thereof which is used for transaction of business for keeping of accounts and records and similar purposes, professional establishments, service facilities, etc. City halls, town halls, courthouses and libraries shall be classified in this group so far as the principal function of these is transaction of public business and keeping of books and records.
Buildings under Group E shall be further subdivided as follows:
Subdivision E-1 Offices, banks, professional establishments, like offices of architects, engineers, doctors, lawyers, post offices and police stations
Subdivision E-2 Laboratories, outpatient clinics, research establishments, libraries and test houses
Subdivision E-3 Electronic data processing centres, computer installations, information technology parks and call centres
Subdivision E-4 Telephone exchanges
Subdivision E-5 Broadcasting stations, T.V. stations and air traffic control towers
3.1.7 Group F Mercantile Buildings
These shall include any building or part thereof, which is used as shops, stores, market, for display and sale of merchandise, either wholesale or retail.
Mercantile buildings shall be further subdivided as follows:
Subdivision F-1 Shops, stores, departmental stores, markets (any with covered area up to 500 m²)
Subdivision F-2 Shops, stores, departmental stores, markets (any with covered area more than 500 m²)
Subdivision F-3 Underground shopping centres Storage and service facilities incidental to the sale of merchandise and located in the same building shall also be included under this group.
3.1.8 Group G Industrial Buildings
These shall include any building or part of a building or structure, in which products or materials of all kinds and properties are fabricated, assembled, manufactured or processed, for example, assembly plants, industrial laboratories, dry cleaning plants, power plants,
generating units, pumping stations, fumigation chambers, laundries, buildings or structures in gas plants, refineries, dairies and saw-mills, etc.
Buildings under Group G shall be further subdivided as follows:
Subdivision G-1 Buildings used for low hazard industries
Subdivision G-2 Buildings used for moderate hazard industries
Subdivision G-3 Buildings used for high hazard industries
The hazard of occupancy, for the purpose of the Code, shall be the relative danger of the start and spread of fire, the danger of smoke or gases generated, the danger of explosion or other occurrences potentially endangering the lives and safety of the occupants of the buildings.
Hazard of occupancy shall be determined by the Authority on the basis of the fire loads of the contents, and the processes or operations conducted in the building, provided, however, that where the combustibility of the material, the flame spread rating of the interior finish or other features of the building or structure are such as to involve a hazard greater than the occupancy hazard, the greater degree of hazard shall govern the classification.
For determination of fire loads and fire load density for arriving at the classification of occupancy hazard, guidance on calorific values of some common materials is given at Annex A.
A broad classification of industrial occupancies into low, moderate and high hazard classes is given at Annex B, for guidance. Any occupancy not covered in Annex B, shall be classified in the most appropriate class depending on the degree of hazard.
Where different degrees of hazard of occupancy exist in different parts of a building, the most hazardous of those shall govern the classification for the purpose of this Code, except in cases where hazardous areas are segregated or protected as specified in the Code.
a) Subdivision G-1 — This subdivision shall include any building in which the contents are of such comparative low combustibility and the industrial processes or operations conducted therein are of such a nature that there is hardly any possibility for any self-propagating fire to occur and the only consequent danger to life and property may arise from panic, fumes or smoke, or fire from some external source.
b) Subdivision G-2 — This subdivision shall include any building in which the contents or industrial processes or operations conducted therein are liable to give rise to a fire which will burn with moderate rapidity or result in other hazardous situation and may give off a considerable volume of smoke, but from which neither toxic fumes nor explosions are to be feared in the event of fire.
3.1.9 Group H Storage Buildings
These shall include any building or part of a building used primarily for the storage or sheltering (including servicing, processing or repairs incidental to storage) of goods, ware or merchandise (except those that involve highly combustible or explosive products or materials), vehicles or animals, for example, warehouses, cold storages, freight depots, transit sheds, storehouses, truck and marine terminals, garages, hangars, grain elevators, barns and stables. Storage properties are characterized by the presence of relatively small number of persons in proportion to the area. Any new use which increases the number of occupants to a figure comparable with other classes of occupancy shall change the classification of the building to that of the new use, for example, hangars used for assembly purposes, warehouses used for office purposes, garage buildings used for manufacturing.
3.1.10 Group J Hazardous Buildings
These shall include any building or part thereof which is used for the storage, handling, manufacture or processing of highly combustible or explosive materials or products which are liable to burn with extreme rapidity and/or which may produce poisonous fumes or explosions for storage, handling, manufacturing or processing which involve highly corrosive, toxic or noxious alkalis, acids or other liquids or chemicals producing flame, fumes and explosive, poisonous, irritant or corrosive gases; and for the storage, handling or processing of any material producing explosive mixtures of dust which result in the division of matter into fine particles subject to spontaneous ignition. Examples of buildings in this class are those buildings which are used for,
a) storage, under pressure of more than 0.1N / mm² and in quantities exceeding 70 m³
of acetylene, hydrogen, illuminating and natural gases, ammonia, chlorine, phosgene, sulphur dioxide, carbon dioxide, methyloxide and all gases subject to explosion, fume or toxic hazard, cryogenic gases, etc;
b) storage and handling of hazardous and highly flammable liquids, liquefiable gases like LPG, rocket propellants, etc;
c) storage and handling of hazardous and highly flammable or explosive materials (other than liquids); and
d) manufacture of artificial flowers, synthetic leather, ammunition, explosives and fireworks.
NOTE — A list of hazardous substances giving quantities, for which or exceeding which owners handling such substances are required to be covered under The Public Liability Insurance Act, 1991, has been notified under the ‘Rules on Emergency Planning, Preparedness and Response for Chemical Accidents’ by the Govt. of India, Ministry of Environment and Forests Notification No. G.S.R. 347(E) dated 01 August 1996.
3.1.11 Mixed Occupancy
In case of mixed occupancy, in so far as fire protection is concerned, all the occupancies/the entire building shall be governed by the most restrictive provisions of the Code among those applicable for individual occupancies. The provisions for life safety given in the Code for individual occupancy shall, however, apply to the respective occupancies. Exits in such mixed occupancy shall be arranged so as to ensure that means of egress is not decreased in the direction of egress travel.
Further, in such mixed occupancies, the occupancies are also required to be separated (horizontally and/or vertically as the case may be) by a 240 min fire resistance rating.
3.1.12 Where change in the occupancy of any building places it in a different group or in a different subdivision of the same group, such building shall be made to comply with the requirements of the Code for the new group or its subdivision.
3.1.13 Where the new occupancy of a building is less hazardous, based on life and fire risk, than its existing occupancy, it shall not be necessary to conform to the requirements of the Code for the new group or its subdivision.
3.1.14 A certificate of occupancy shall be necessary, as required under Part 2 ‘Administration’ of the Code, before any change is effected in the character of occupancy of any building.