(1) Setbacks
a. For Plots abutting the major roads having right of way (authorized or master plan R.O.W) equal to or more than 18.0 mt., the following front setbacks OR the setbacks prescribed for different buildings in 6.2 (1).b., (whichever is higher), shall be provided:
| S. No. | Right of Way (in mt.) | Front Setback (in mt.) |
|---|---|---|
| 1 | 18.0 | 3.0 |
| 2 | 24.0 | 4.0 |
| 3 | 45.0 | 6.0 |
| 4 | 50.0 | 7.0 |
Table 8: Building Line
b. For buildings of 12.0 to 15.0 mt. height, provision of minimum 5.0 mt. open space / setbacks shall be made around the building and thereafter for every 3.00 mt. height or part of it, additional setback of 1.00 or the setback prescribed below, whichever is more is required to be provided.Setbacks for building upto 12.00mt. height shall be as under:
(i) Residential
| PlotArea (sq. mt.) | Minimum Required Setback (mt.) | |||||||
| Plains | Hill Areas | |||||||
| Front | Back | Side-1 | Side-2 | Front | Back | Side-1 | Side-2 | |
| 30-45 | 1.2 | - | - | - | 1.2 | - | - | - |
| Above 45 up to 75 | 1.5 | - | - | - | 1.5 | - | - | - |
| Above 75 upto 150 | 2.0 | 1.5 | - | - | 1.5 | 1.2 | - | - |
| Above 150 upto 300 | 3.0 | 2.0 | - | - | 2.0 | 1.5 | - | - |
| Above 300 upto 500 | 4.5 | 3.0 | 1.5 | 3.0 | 2.0 | 1.5 | ||
| Above 500 upto 750 | 5.5 | 3.5 | 3.0 | 2.0 | 4.0 | 2.5 | 2.5 | 2.0 |
| Above 750 upto1000 | 6.5 | 4.0 | 3.5 | 3.0 | 5.0 | 3.5 | 3.5 | 3.5 |
| Above 1000 | 7.5 | 4.0 | 4.0 | 4.0 | 6.0 | 4.0 | 4.0 | 4.0 |
| Group Housing / Affordable Housing | 8.5 | 5.0 | 5.0 | 5.0 | 7.0 | 4.5 | 4.5 | 3.0 |
Table 3: Minimum required setbacks for Residential Buildings
• Minimum 1.2 mt. open to sky space is required to be provided from the retaining wall.
In corner plots, Front setback of the plot shall be provided for relatively wider road and the setback towards the other side shall be half of the front setback or equal to side setback whichever is lower. In case, in a corner plot both the roads are equal, the front setback shall be as per design of the building and the side setback shall be towards the other road. For road widths above 7.5 mt , the setbacks shall be as per clause 6.2 (2) after leaving the splay area.
In the plots having roads in front and in back, in case of being wider / equal, the front setback shall be towards the side from where the approach is being taken and the setback of other side shall be half of the front or equal to setback in the back, whichever more.
• In case the road ends in a part of the plot, front setback shall be given towards the road.
Construction shall be permissible in the 40 percent area of rear setback of maximum 7.0 mt. height but in a corner plot the above shall not be permissible on road side. However in the corner plots having a dead end up to the length of the said plot,the said coverage shall be permissible on road side, .The said coverage may consist of garage (maximum area 25 sq. mt.) servant room with toilet (maximum area 25 sq.mt.) / kitchen / storeshall be permissible and shall be counted in F.A.R. and ground coverage. The minimum width of drive way for approach to garage should be 2.40 mt.
In matters of single residential building stilt floor shall be permissible only in semi-detached building (open from minimum two sides, namely open from front and back with setback) but in suchbuilding no construction shall be allowed on 40 percent portion of the rear side setback.
In case there is any other private passage in addition to the main road, minimum 1.00 mt.setback towards the private passage or rear / back-side setback, whichever is more is required to be provided along with prescribed front setback. In case a dead setback is permissible and owner wants to provide setback voluntarily then its minimum width shall be 1.20 mt.
Multiple units shall compulsorily be built as detached building. In the setbacks described in the above table, setbacks shall be provided for multiple units with an increase of 1.00 mt. in each setback
In matters of single residential buildings, if the F.A.R. could not be obtained due to setback provided for the plot. The setback of a lower level plot area category shall be effective.
(ii) Commercial / Office
| Commercial / Office Plot Area (sq. mt.) | Minimum Required Setback (mt.) | |||||||
| Plains | Hill Areas | |||||||
| Front | Back | Side-1 | Side-2 | Front | Back | Side-1 | Side-2 | |
| Upto 200 | 4.5 | - | - | - | 3.0 | - | - | - |
| Upto 400 | 6.0 | 2.0 | 3.0 | - | 4.0 | - | - | - |
| Upto 600 | 7.5 | 3.0 | 3.0 | - | 5.0 | 2.0 | 2.0 | - |
| Upto 1000 | 8.0 | 3.0 | 4.0 | 1.5 | 6.0 | 3.0 | 3.0 | 1.5 |
| Upto 1500 | 9.0 | 4.0 | 4.5 | 3.0 | 7.0 | 4.0 | 3.5 | 3.0 |
| Upto 3000 | 10.0 | 5.0 | 4.5 | 4.5 | 8.0 | 5.0 | 4.5 | 4.5 |
| Above 3000 | 12.0 | 6.0 | 6.0 | 6.0 | 9.0 | 6.0 | 6.0 | 6.0 |
| Mall / Multiplex | Front | Back | Side-1 | Side-2 | Front | Back | Side-1 | Side-2 |
| Upto 4000 | 14.0 | 6.0 | 6.0 | 6.0 | 10.0 | 6.0 | 6.0 | 6.0 |
| 4001 to 15,000 | 16.0 | 7.0 | 7.0 | 7.0 | 12.0 | 6.0 | 6.0 | 6.0 |
| 15,001 to 50,000 | 18.0 | 8.0 | 8.0 | 8.0 | 14.0 | 6.0 | 6.0 | 6.0 |
| Above 50,000 | 20.0 | 9.0 | 9.0 | 9.0 | 18.0 | 6.0 | 6.0 | 6.0 |
Table 104: Minimum required setbacks for Commercial / Office Buildings
Note:
Construction towards the retaining wall of the plot shall be permissible after leaving 1.2 mt. open space.
For commercial construction no shops shall be opened on the road in the side / rear setback of the building. In case any opening / shops are opened towards the sides or towards the back, the setback equal to front, is to be required to be provided.
In case of the plot located on more than one road (plots in which side / back setback is not required) the front setback shall be towards the wider road and minimum 3.0 mt.setback is to be provided towards the other road.
(iii) Educational Institutes / Medical / Community facilities / Assembly buildings
| Area ofPlot(sq. mt.) | Required MinimumSetback (mt.) | |||||||
| Plains Area | Hill Areas | |||||||
| Front | Back | Side-1 | Side-2 | Front | Back | Side-1 | Side-2 | |
| Upto 1000 | 6.0 | 4.5 | 3.6 | 3.6 | 4.5 | 3.6 | 3.6 | 3.6 |
| 1001 to 3000 | 7.5 | 4.5 | 4.5 | 4.5 | 5.0 | 4.5 | 4.5 | 3.6 |
| 3001 to 8000 | 9.0 | 6.0 | 4.5 | 4.5 | 7.5 | 5.0 | 4.5 | 4.5 |
| 8001 to 15,000 | 12.0 | 6.0 | 6.0 | 6.0 | 9.0 | 6.0 | 6.0 | 6.0 |
| 15,001 to 35,000 | 15.0 | 6.0 | 6.0 | 6.0 | 12.0 | 6.0 | 6.0 | 6.0 |
| Above 35,000 | 18.0 | 6.0 | 6.0 | 6.0 | 15.0 | 6.0 | 6.0 | 6.0 |
Table 11: Minimum required setbacks for Educational Institutes / Medical / Community facilities / Assembly buildings
Note:
In newly proposed schools (except nursery schools), 6.0 mt. width of front setback shall be left towards road side for visitor parking. Boundary wall shall be constructed after leaving the above mentioned space.
(iv) Industrial Buildings
| Area ofPlot (sq. mt.) | Required MinimumSetback (mt.) | |||||||
| Plains Area | Hill Areas | |||||||
| Front | Back | Side-1 | Side-2 | Front | Back | Side-1 | Side-2 | |
| Upto 300 | 3.0 | 2.0 | 2.5 | - | 3.0 | 2.0 | 1.5 | - |
| 301 to 600 | 4.0 | 3.0 | 3.5 | - | 3.5 | 3.0 | 3.0 | - |
| 601 to 1200 | 5.0 | 3.0 | 3.5 | 2.0 | 4.0 | 3.0 | 3.0 | 2.0 |
| 1201 to 2400 | 7.5 | 5.5 | 4.5 | 3.0 | 6.0 | 4.0 | 4.0 | 3.0 |
| 2401 to 5,000 | 9.0 | 6.5 | 5.5 | 5.0 | 7.5 | 5.5 | 5.0 | 5.0 |
| 5001 to 10,000 | 12.0 | 7.5 | 6.5 | 6.5 | 9.0 | 6.5 | 6.0 | 6.0 |
| 10,001 to 30,000 | 18.0 | 9.0 | 7.5 | 7.5 | 12.0 | 7.5 | 6.5 | 6.5 |
| 30,000 to 6.0 hectares | 20.0 | 12.0 | 9.0 | 9.0 | 18.0 | 9.0 | 7.5 | 7.5 |
| Above 6.0 hectares | 25.0 | 15.0 | 12.0 | 12.0 | 20.0 | 12.0 | 9.0 | 9.0 |
Table 52: Minimum required setbacks for Institutional Buildings
(2) Splay at road junctions, including ‘Y’ junctions:
Splay required at road junctions is given in the Table below. The area of splay would be deemed to form part of the road junction.
| Sl. No. | Road Width (in m) | Splay / Offset (in m) |
|---|---|---|
| 1 | Above 7.5 up to 12 | 3.0 x 3.0 |
| 2 | Above 12 up to 24 | 4.5 X 4.5 |
| 3 | Above 24 | 6 X 6 |
Table 6: Splay required at road junctions
The setbacks overlooking the splay shall be as per the front setback of wider road. The area of the splay shall form part of the right of way.

(3) Distance between two blocks
On the basis of the height of tallest block, the distance required between two blocks shall be as:
(i) Distance between two blocks with 10.0 mt. height = 3.0 mt.
(ii) Distance between two blocks with 12.0 mt. height = 4.0 mt.
(iii) Distance between two blocks above12.0 mt. height = Additional 1.0 mt. for every 3.0 mt.increase in height.
(4) Relaxation in Setbacks
Following relaxation may be allowed in setbacks for the buildings:
(i) Balcony, roof / overhang of maximum 1.8 mt. width may be constructed in set- back / open space in a plot. The increased part beyond 1.80 mt. shall be counted in F.A.R. This construction shall not be more than one-third of the width of setback.
(ii) A canopy or canopies each not exceeding 4.50 m. in length and 2.40 m. in width, in the form of cantilever or cantilevers, over the main entrance/entrances, providing a minimum clear height of 2.2 m. below the canopy.
(iii) An arbour / pergola of maximum 6.0 sq. mt. area having minimum 40 percent open space and minimum 2.2 mt. height shall be permissible.
(iv) Construction of ramp within setback for approach to maximum one subsequent floor of ground floor and basement shall be permissible by keeping the required area obstruction free and for easy approach of fire tender for fire safety. Such constructions shall be permitted after leaving 3.6 mt and 6.0 mt unobstructed pathway from low rise and high rise buildings respectively
(v) In hill areas, owing to the undulating topography of the site the construction within 50 percent width of each setback shall be permissible with the restriction that there shall be no increase in prescribed ground coverage and F.A.R.
(vi) Internal path shall be permissible within the setback area.
(vii) Maximum 33% area of the total setback area can be utilized for parks / organized green spaces provided the area required for easy maneuvering and movement of fire tender for fire safety is kept free of any kind of obstruction which shall be permitted after leaving 3.6 mt and 6.0 mt unobstructed pathway from low rise and high rise buildings respectively
(viii) In all matters except single residential and multiple units, no parking shall be permissible in setback area. In group housing projects parking shall be permitted after leaving 3.6 mt and 6.0 mt unobstructed pathway from low rise and high rise buildings respectively in 25 percent area of the total setback.