(i) In case of provision of stilts, Structural and soil bearing capacity certification and related plans prepared as per IS byelaws shall be furnished by the empanelled structural engineer. Stilts can be provided on any floor.
(ii) One stilt floor shall be excluded from the computation of F.A.R. and height of building only in case if the Internal unobstructed height of stilt(Ground floor to ceiling / level under the beam, whichever is lower) being maximum 2.40 mt. and being used only for parking and essential facilities. However, stilts shall be counted in height and FAR for computation of fire safety related norms.
(iii) In case a second stilt parking facility is provided in addition to the stilt floor on ground floor, it shall be computed in height and excluded in F.A.R computation.
(iv) Stilt parking shall be permissible which shall be open minimum from three sides and in case covered by wall / shutter / glazing towards the setback, it shall be treated as covered parking and shall be computed in the F.A.R. and in height.
(v) In small plots having area less than or equal to 200 sq. mt., to promote parking space, stilts can be constructed covered from all three sides provided the front is kept open and an affidavit is given by the owner that the stilt shall be used as parking only. In case the stilt is used for other purpose, the sanctioned plan will be cancelled.
7.3Basement and Basement Parking
Basement means a construction having a minimum 50 percent part of its height below the lowest ground level of the site. Depending upon the special topography of the site, it may be determined by the authority as per the definition in N.B.C-2016. The basement shall be used for parking, storage and utility
(1) Permissibility of Basement shall be as:
One Basement
More than One Basement
Hills
Single basement allowed in plots having minimum 18.0 mt. frontage as well as width AND minimum plot area 2000sq. mt.
not permitted
Plains
Upto plot size 750 sq. mt., 20% of the plot may be used for single basement meant for storage purpose and shall be accessible internally from building above
maximum three basements permitted in plots having 24 mt. frontage as well as width AND minimum plot area 4000sq. mt.
For plot size more than 750 sq. mt. single basement may be used for parking purposes
Table 10: Permissibility of Basement
(2) The basement may be put to following uses:
a. Parking
b. Storage of household or other goods of ordinarily non-combustible material;
c. Strong rooms, bank cellars, etc.;
d. Air-conditioning equipment and other machines used for services and utilities of the building.
e. Only in case of High Rise Buildings, up to 10% of basement may be utilized for utilities and non-habitation purpose like A/C Plant room, Generator room, Sewerage Treatment
Plant (STP), Electrical installations, Laundry, etc. This is allowed only after fulfilling the required parking spaces.
(3) The use of basement shall be specified in the building plans at the time of submission.
(4) The maximum expanse (ground coverage) of basement shall be 50% of the total plot area and shall be within the limits after leaving the required setback.
(5) Plots bearing dead setbacks as per norms shall be eligible to construct single basement provided minimum setbacks as stipulated below are provisioned instead of dead setback for the basement as well as for the superstructure. In other plots where setbacks are defined, the below tabulated or the defined setbacks, (whichever is more) shall be applicable.
S. No.
Height of the Building
Front Setback
Setback to be left on other sides
1
upto 9.0 mt.
3.6 mt
2.0 mt.
2
upto 12.0 mt.
4.5 mt
3.0 mt.
3
upto 15.0 mt.
4.5 mt
4.0 mt.
4
more than 15.0 mt.
4.5 mt
6.0 mt.
Table 11:Setbacks to be left based on height of the building for construction of basement
(6) The basement shall be admissible below the landscaped open areas with this restriction that the ceiling slab of basement shall not be more than ground floor (flushed with ground level and property landscaped as open / green space) and recharge borewells are provided adequately for ground water recharging. In case of podium construction, the green areas may be proposed over the podium with a condition that recharge borewells are provided adequately for ground water recharging.
(7) Provision of open ramp for access to the basement in setback area shall be permitted after leaving the requisite space for fire tender movement around the building [ie. 3.60 mt. and 6.0 mt respectively from low rise and high rise construction].
(8) The maximum travel distance from any point in basement shall be according the National Building Code.
(9) For basement, the Empanelled structural engineer shall furnish structural plans alongwith an affidavit regarding the suitability of the basement w.r.t bearing capacity of the soil, liquefaction and water table and the effect of excavation of basement on stability of neighboring buildings.
(10) The basement shall have the following provisions:
Light and ventilation of basement
a. An open area of a minimum width of 1.8 mt. shall be provided across the full length and / or width of the basement storey. This area shall be within the limits of the site and shall be paved with impervious material above a concrete bed. It shall be completely unobstructed except that in this area steps may be allowed for access to it, if considered necessary.
b. Basement storeys shall be lighted and ventilated by means of windows of the minimum area within 1 / 10th to 1 / 25th of the total floor area, at least half of which must open subject to the condition that the deficit of light and ventilation shall be made up by providing artificial lighting and mechanical ventilation as per provision of National Building Code of India.
c. In the second basement and basement below the lower ground floor where it is to be used for parking / services, the provisions contained in National Building Code and Fire Safety Byelaws as applicable shall be followed.
d. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air-conditioning systems, etc.
(ii) Damp proofing of Basement
The walls of the basement storey shall be properly damp proofed and if in contact with the soil, they must be effectively secured against dampness from the soil with the approved vertical and horizontal damp proof course.
(iii) Height of the Basement
a. The minimum clear height of the basement shall be 2.4 mt. and maximum clear height of the basement shall be up to 4.75 mt.from floor to the underside of the roof slab or ceiling subject to structural stability to be certified by the Structural Engineer.
b. The minimum height of the roof of basement shall be 0.9 mt. and maximum 1.20mt. above the average surrounding ground level for plots upto 1000 sq. mt.
c. For plots above 1000 sq. mt., the roof of basement shall be either flushed with ground or the maximum height shall be 1.20 mt. above the average surrounding ground level.
(iv) Drainage of Basement
a. Open area adjoining a basement storey, if any, shall be effectively drained to the satisfaction of the Competent Authority.
b. The responsibility of draining a basement storey and for protecting it from rain shall be that of the owner.
c. The access to the basement shall be separate from the main and alternative staircase providing access and exit from higher floors.
d. Where the staircase is continuous in the case of buildings served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors.
e. The “Exit” requirements in basements shall comply with the provisions ofPart 4 ‘Fire and Life Safety’ of National Building Code of India.
Chapter 7Building Design Norms
7.1 Parking
(1) Computation of parking areas
(i) Based upon the type of parking, the Equivalent Car Space [ECS] norms shall be as follows which is inclusive of the circulation space and ramp.
a. Open area Parking / Terrace parking on road level: 23 sq. mt.
b. Covered parking / stilt parking:28 sq. mt.
c. Basement / *terrace / * subsequent floors of ground floor: 32 sq. mt.
d. Fully mechanized parking in the basement / *terrace / * subsequent floor of ground floor: 16 sq.mt. or as per standard design for such parking
e. Stack parking / double decker parking: In case of provision of mechanical slot the E.C.S. of the floor on which stack parking is proposed shall be according to the type of floor viz; basement, terrace, stilt and open space as the case may be and in subsequent slots it shall be minimum 16sq. mt. per ECS.
For example, stack parking / double decker parking in non-mechanized parking in basement of 1000 sq. mt. area.
ECS of basic floor = 1000 / 32=31 ECS
ECS in subsequent slots = 1000 / 16=62 ECS
Total ECS that can be accommodated in this basement = 31+62= 93ECS
f. The minimum area for equivalent car space for residential (plotted) development shall be 13.75 sq.mt. per plot.
*Terrace parking / parking on subsequent floor of ground floor, shall be permissible only in plots having total minimum plot area 1000 sq. mt.(one side of plot must be minimum 25 mt. wide). Terrace parking on road level / on terrace can be covered by shed whose sides shall remain open.
(ii) As an alternative to above E.C.S. provisions, the provision of ‘parking bay’ shall be permissible by considering a ‘parking bay’ of 2.75 mt.X 5.0 mt. equivalent to an E.C.S with the condition that proper approach / driveway / aisle / circulation is available for parking bay slots as per design standard.
(iii) The ramp to basement and parking floors shall not be less than 7.2mt. wide for two way traffic and 4.2 mt. wide for one way traffic, with gradient not steeper than 1:10.
(2) Parking Norms
The norms for parking in the respective plots for building of different occupancy shall be as under. In hill area these norms shall be 25 percent less than from the norms prescribed here:
Occupancy Building
Parking Space
For Single Housing unit
ECS
a
On 100-200 sq.mt. floor area
One parking place of 13.5 sq.mt. (5.0 mt. x 2.75 mt.) 1.00 ECS
b
On floor area above 200sq., mt.
1.00 ECS on per 100 sq.mt. covered area or part thereof
Occupancy of Building
Parking Space on per 100sq.mt. covered area or part
For Multiple Residential Unit
1.00 ECS
Group Housing
On each unit of 50-75 sq.mt. floor Area
1.00 ECS
On each unit of 75-150 sq.mt. floor area
1.25 ECS
On each unit above 150 sq.mt. floor Area
1.50 ECS
Commercial Use
On plots of upto 50 sq.mt.
--
On plots of upto 250 sq.mt.
1.00 ECS
On plots above 250 upto 500 sq.mt.
1.50 ECS
On plots of above 500 to 1500 sq.mt.
2.00 ECS
On plots of above 1500 sq.mt.
2.50 ECS
Wholesale market- Freight Complex
3.50 ECS
Mall, Multiplex - Multiplex- Commercial, mixed use / Cinema hall
3.50 ECS
Hotel
2.50 ECS
Lodging / Tourist home / Musafirkhana / Dharamshala / Guest house / Resort / stand-alone private Hostel
1.50 ECS
Hostels inside educational institutions
0.75 ECS
Community hall / Auditorium
2.00 ECS
Ashram, Cultural or Social institution
1.50 ECS
Nursing home / Primary health center / hospital
2.00 ECS
Wedding Point
30 percent of total area of scheme or parking space on the basis of per 100 sq.mt. covered area or part thereof, whichever is more
Office, Court, other Offices
2.50 ECS
Primary, Middle School, High School / Inter College
1.25 ECS
Degree College, University, High Standard / Technical Educational Institutes
1.50 ECS
Information Technology Campus and Unit under related unit
2.00 ECS
Industry
Domestic / Services / Small industry
0.60 ECS
Other industry
0.75 ECS
Godown, Cold Storage
1.00 ECS
Stadium (one ECS on 20 seats)
-
Amusement park / other entertainment place / exhibition place (3.0 percent of total area of scheme)
-
Other Community Hall
1.50 ECS
Table 20: Parking Space Requirement based on type of occupancy of building
(3) Other miscellaneous provisions for parking
(i) Minimum 25 percent of total parking shall be required to be provisioned as open parking for group housing.
(ii) In all building/uses except single residential and multiple units, parking shall not be permissible in setback area and in case of group housing parking shall be permissible in maximum 25 percent area of the setback after leaving a regular shaped pathway of minimum width 3.60 mt. and 6.0 mt respectively from low rise and high rise construction.
(iii) In schemes of one acre and above area, in case a multi-level parking block is constructed, a ground coverage of 5 percent more than the prescribed shall be permissible under building envelope, which will be used for parking only. The said 5 percent shall not be included in F.A.R. However, the footprint of separate parking building blocks shall be counted towards ground coverage.
(iv) The plan of parking proposal shall also be submitted with the plans of high rise building proposed for group housing and non-residential purpose and the parking plan shall be shown along with the provision of circulation / ramp for their proper entry and exit.
(v) The covered parking in the basement or in the form of stilt above ground level shall not be counted towards Floor Area Ratio (FAR).
(vi) In case of provision of stack parking in the basement floor / upper stories, the floor to ceiling clear height of the basement / floor may be maximum of 4.75 mt.
(vii) No storage and commercial activities shall be permitted in the covered parking areas.
7.4Courtyard
(i) The courtyard shall have a minimum area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard. Provided that when any room (excluding staircase bay, bathroom and water-closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(ii) Provided that such courtyard shall not be less than 12.0 sq. mt. in area and the minimum width of every such courtyard in any direction shall not be less than 3.0 mt.
(iii) The area of the courtyard for the purposes of these Byelaws shall be the area open to sky, clear of all projections.
7.5 Plinth
(i) The plinth of the main building shall be so located with respect to surrounding ground level that proper drainage of the site is assured. The height of the plinth shall not be less than 450 mm (0.45 mt.).
(ii) In no case, any part of the ramp / steps connecting building plinth to street / roadshall lie on street / road and obstruct traffic movement. However, the ramp / step from the plot boundary to the entry of house building, if required shall be provided.