This Section covers requirements and guidelines regarding planning against noise, acceptable noise levels and the requirements for sound insulation in buildings with different occupancies.
To reduce the transmission of air-borne noise, sound insulating materials may be used. Sound insulating materials block the passage of noise through them by virtue of their mass and physical properties. The extent of noise reduction provided by a single homogeneous panel is proportional to the logarithm of mass per unit area. For high values of sound insulation, normally heavy panels are required. Thin sheets of materials do not have adequate mass for providing any appreciable sound transmission loss by themselves. However, when thin sheet materials are used in a double panel construction with an intervening air cavity, this special construction can give extremely high sound transmission loss values considering the mass of the partition, if designed properly. Porous materials lack the mass required to provide any appreciable sound transmission loss, and readily allow sound at most frequencies to be transmitted through them.
To reduce the transmission of structure-borne noise (such as, noise generated by impacts) special construction methods and elastic discontinuity in the structure may be used. Structure-borne noise reduction is effected by corner joints, changes in cross-section, changes in materials, etc, in construction. The reduction by these construction methods is, however, not appreciable specially when a large amount of noise reduction is required over a short distance. In such cases, introduction of an elastic discontinuity in the structure can result in a very large amount of noise reduction. The noise transmission is affected only above a certain lower frequency which depends on the material thickness and the elastic properties of the material. Bonded fibrous materials, rubber elastomers, cork, etc, are suitable for curtailing structure-borne noise transmission.
This Section is largely based on the following standards:
IS 1950 : 1962 Code of practice for sound insulation of non-industrial buildings
IS 3483 : 1965 Code of practice for noise reduction in industrial buildings
IS 4954 : 1968 Recommendations for noise abatement in town planning
IS 11050 Rating of sound insulation in buildings and of building elements:
(Part 1) : 1984 Airborne sound insulation in buildings and of interior building elements
(Part 2) : 1984 Impact sound insulation
BS 8233 : 1999 Code of practice for sound insulation and noise reduction for buildings
In this revision, opportunity has been taken to update all references to relevant Indian Standards referred to in the text.
All standards, whether given herein above or cross-referred to in the main text of this Section, are subject to revision. The parties to agreement based on this Section are encouraged to investigate the possibility of applying the most recent editions of the standards.
2.0 For the purpose of this Section, the following definitions shall apply.
2.1 Ambient Noise — The sound pressure levels associated with a given environment. Ambient noise is usually a composite of sounds from near and far sources none of which are particularly dominant.
2.2 Audible Frequency Range — The range of sound frequencies normally heard by the human ear. The audible range spans from 20 Hz to 20 000 Hz.
2.3 A-Weighted Sound Pressure, p — Value of p A overall sound pressure, measured in pascals (Pa), after the electrical signal derived from a microphone has been pased through an A-weighting network.
NOTE — The A-weighting network modifies the electrical response of a sound level meter with frequency in approximately the same way as the sensitivity of the human hearing system.
2.4 A-Weighted Sound Pressure Level, L p A - Quantity of A-weighted sound pressure, given by the following formula in decibels (dBA):
where
p A = is the A-weighted sound pressure in pascals (Pa); and
p o = is the reference sound pressure (20 μ Pa).
NOTE — Measurements of A-weighted sound pressure level can be made with a meter and correlate roughly with subjective assessments of loudness, and are usually made to assist in judging the effects of noise on people. The size of A-weighting in 1/3 octave bands, is shown in Annex A (see A-5). An increase or decrease in level of 10 dBA corresponds roughly to a doubling or halving of loudness.
2.5 Background Noise — The sound pressure levels in a given environment from all sources excluding a specific sound source being investigated or measured.
2.6 Break-in — Unwanted sound transmission into a duct from outside.
2.7 Break-out — Unwanted sound transmission from inside a duct to the outside.
5
2.8 Broad Band Noise — Spectrum consisting of a large number of frequency components, none of which is individually dominant.
2.9 Cross-Talk — Unwanted sound transmission between one room and another room or space via a duct.
2.10 Decibels — Ten times the logarithm (to the base 10) of the ratio of two mean square values of sound pressure, sound power or sound intensity. The abbreviation for ‘decibels’ is dB.
2.11 Effective Perceived Noise Level in Decibel (EPN dB) — The number for rating the noise of an individual aircraft flying overhead is the effective perceived noise level in decibels (EPN dB). The effective perceived noise decibel value takes into account the subjectively annoying effects of the noise including pure tones and duration. In principle, it is a kind of time-integrated loudness level.
2.12 Equivalent Continuous A-Weighted Sound Pressure Level, L A e q . T — Value of the A-weighted sound pressure level in decibels (dB) of a continuous, steady sound, that within a specified time interval, T, has the same mean squared sound pressure as the sound under consideration that varies with time, given by the formula:
where
p A ( t ) = is the instantaneous A-weighted sound pressure in pascals (Pa); and
p _ 0 = is the reference sound pressure (20 μ Pa).
NOTE — Equivalent continuous A-weighted sound pressure level is mainly used for the assessment of environmental noise and occupational noise exposure.
2.13 Equivalent Sound Absorption Area of a Room, A — Hypothetical area of a totally absorbing surface without diffraction effects, expressed in square metres (m2) which, if it were the only absorbing element in the room, would give the same reverberation time as the room under consideration.
2.14 Facade Level — Sound pressure level measured 1 m to 2 m in front of the façade.
NOTE — Facade level measurements of L _ p A are usually 2 dB to 3 dB higher than corresponding free-field measurements.
NOTE — Measurements made 1.2 m to 1.5 m above the ground and at least 3.5 m away from other reflecting surfaces are usually regarded as being free-field measurements. To minimize the effect of reflections the measuring position should be at least 3.5 m to the side of the reflecting surface (that is, not 3.5 m from the reflecting surface in the direction of the source). Estimates of noise from aircraft overhead usually include a correction of 2 dB to allow for reflections from the ground.
2.16 Frequency — The number of cyclical variations per unit time. Frequency is generally expressed in cycles per second (cps) and is also denoted as Hertz (Hz).
2.17 Impact Sound Pressure Level, L i ~ — ~ A v e r a g e sound pressure level in a specific frequency band in a room below a floor, when it is excited by a standard tapping machine.
2.18 Indoor Ambient Noise — Pervasive noise in a given situation at a given time, usually composed of noise from many sources, inside and outside the building, but excluding noise from activities of the occupants.