Part 8 Section 4Acoustics, Sound Insulation and Noise Control
To reduce the transmission of air-borne noise, sound insulating materials may be used. Sound insulating materials block the passage of noise through them by virtue of their mass and physical properties. The extent of noise reduction provided by a single homogeneous panel is proportional to the logarithm of mass per unit area. For high values of sound insulation, normally heavy panels are required. Thin sheets of materials do not have adequate mass for providing any appreciable sound transmission loss by themselves. However, when thin sheet materials are used in a double panel construction with an intervening air cavity, this special construction can give extremely high sound transmission loss values considering the mass of the partition, if designed properly. Porous materials lack the mass required to provide any appreciable sound transmission loss, and readily allow sound at most frequencies to be transmitted through them.
To reduce the transmission of structure-borne noise (such as, noise generated by impacts) special construction methods and elastic discontinuity in the structure may be used. Structure-borne noise reduction is effected by corner joints, changes in cross-section, changes in materials, etc, in construction. The reduction by these construction methods is, however, not appreciable specially when a large amount of noise reduction is required over a short distance. In such cases, introduction of an elastic discontinuity in the structure can result in a very large amount of noise reduction. The noise transmission is affected only above a certain lower frequency which depends on the material thickness and the elastic properties of the material. Bonded fibrous materials, rubber elastomers, cork, etc, are suitable for curtailing structure-borne noise transmission.
This Section is largely based on the following standards:
IS 1950 : 1962 Code of practice for sound insulation of non-industrial buildings
IS 3483 : 1965 Code of practice for noise reduction in industrial buildings
IS 4954 : 1968 Recommendations for noise abatement in town planning
IS 11050 Rating of sound insulation in buildings and of building elements:
(Part 1) : 1984 Airborne sound insulation in buildings and of interior building elements
(Part 2) : 1984 Impact sound insulation
BS 8233 : 1999 Code of practice for sound insulation and noise reduction for buildings
In this revision, opportunity has been taken to update all references to relevant Indian Standards referred to in the text.
All standards, whether given herein above or cross-referred to in the main text of this Section, are subject to revision. The parties to agreement based on this Section are encouraged to investigate the possibility of applying the most recent editions of the standards.
This Section covers requirements and guidelines regarding planning against noise, acceptable noise levels and the requirements for sound insulation in buildings with different occupancies.
2.23Noise Reduction Co-efficient (NRC)
A single figure descriptor of the sound absorption property of a material. It is the arithmetic mean of the sound absorption co-efficients at 250, 500, 1 000 and 2 000 Hz rounded off to the nearest multiple of 0.05.
2.24 Normalized Impact Sound Pressure Level, L n — Impact sound pressure level normalized for a standard absorption area in the receiving room.
NOTE — Normalized impact sound pressure level is usually used to characterize the insulation of a floor in a laboratory against impact sound in a stated frequency band (see Annex B).
2.25 Octave Band — Band of frequencies in which the upper limit of the band is twice the frequency of the lower limit.
2.26 Percentile Level, L A N , T - A -weighted sound pressure level obtained using time-weighting ° F which is exceeded for N percent of a specified time interval.
Example:
L A 9 0 , 1 h is the A-weighted level exceeded for 90 percent of 1 h. Percentile levels determined over a certain time interval cannot accurately be extrapolated to other time intervals. Timeweighting F ~ o r ~ S can be selected on most modern measuring instruments and used to determine the speed at which the instrument responds to changes in the amplitude of the signal. Time-weighting ° F ′ is faster than ° S ′ and so its use can lead to higher values when rapidly changing signals are measured.
2.27 Pink Noise — Sound with an uninterrupted frequency spectrum and a power which is steady within frequency band and proportional to centre frequency. An example is constant power level per octave band.
2.28 Pure Tone — A sound emitted at a single frequency.
2.29 Rating Level, L A r , T r — Equivalent continuous A-weighted sound pressure level of the noise, plus any adjustment for the characteristic features of the noise.
NOTE — This definition is used for rating industrial noise, where the noise is the specific noise from the source under investigation.
2.30 Reverberation Time, T — Time that would be required for the sound pressure level to decrease by 60 dB after the sound source has stopped.
NOTE — Reverberation time is usually measured in octave or third octave bands. It is not necessary to measure the decay over the full 60 dB range. The decay measured over the range 5 dB to 35 dB below the initial level is denoted by T and over the range 5 dB to 25 dB below the initial level by T
2.0 For the purpose of this Section, the following definitions shall apply.
2.1 Ambient Noise — The sound pressure levels associated with a given environment. Ambient noise is usually a composite of sounds from near and far sources none of which are particularly dominant.
2.2 Audible Frequency Range — The range of sound frequencies normally heard by the human ear. The audible range spans from 20 Hz to 20 000 Hz.
2.3 A-Weighted Sound Pressure, p — Value of p A overall sound pressure, measured in pascals (Pa), after the electrical signal derived from a microphone has been pased through an A-weighting network.
NOTE — The A-weighting network modifies the electrical response of a sound level meter with frequency in approximately the same way as the sensitivity of the human hearing system.
2.4 A-Weighted Sound Pressure Level, L p A - Quantity of A-weighted sound pressure, given by the following formula in decibels (dBA):
3 0 °
2 0 °
2.31 Sound — A vibrational disturbance, exciting hearing mechanisms, transmitted in a predictable manner determined by the medium through which it propagates. To be audible the disturbance shall have to fall within the frequency range of 20 Hz to 20 000 Hz.
2.32 Sound Exposure Level, L A E - Level of a sound, of 1 s duration, that has the same sound energy as the actual noise event considered.
1 The L A E of a discrete noise event is given by the formula:
P (t) = is the instantaneous A-weighted sound pressure in pascals (Pa);
t 2 – t 1 = is a stated time interval in seconds (s) long enough to encompass all significant sound energy of the event;
p o = is the reference sound pressure level (20μ Pa); and
t o = is the reference time interval (1 s).
2 L A E is also known as L A X (single-event noise exposure level).
2.33 Sound Power — The acoustic power of a sound source, expressed in Watts.
2.34 Sound Power Level, L w — The acoustic power radiated from a given sound source as related to a reference power level (typically 1 0 - 1 2 watts) and expressed in decibels as:
W = Acoustic power in watts.
By definition, 1 W therefore corresponds to 120 dB for L w
2.35 Sound Pressure, p — Root-mean-square value of the variation in air pressure measured in pascals (Pa), above and below atmospheric pressure, caused by the sound.
2.36 Sound Pressure Level, L p - Quantity of sound pressure, in decibels (dB), given by the formula:
p = is the root mean square sound pressure in pascals (Pa); and
p o = is the reference sound pressure (20μ Pa).
NOTE — The range of sound pressures for ordinary sounds is very wide. The use of decibels gives a smaller, more convenient range of numbers. For example, sound pressure levels ranging from 40 dB to 94 dB correspond to sound pressures ranging from 0.002 Pa to 1 Pa. A doubling of sound energy corresponds to an increase in level of 3 dB.
2.37 Sound Receiver — One or more observation points at which sound is evaluated or measured. The effect of sound on an individual receiver is usually evaluated by measurements near the ear or close to the body.
2.38 Sound Reduction Index, R — Laboratory measure of the sound insulating properties of a material or building element in a stated frequency band.
NOTE — For further information see Annex B.
2.39 Sound Source — Equipment or phenomena which generate sound. Source room is the room containing sound source.
2.40 Spectrum — A quantity expressed as a function of frequency, such as sound pressure versus frequency curve.
2.41 Standardized Impact Sound Pressure Level, L n T - Impact sound pressure level normalized to a reverberation time in the receiving room of 0.5 s.
NOTE — Standardized impact sound pressure level is used to characterize the insulation of floors in buildings against impact sound in a stated frequency band (see Annex B).
2.42 Speech Interference Level (SIL) — A descriptor for rating steady noise according to its ability to interfere with conversation between two people. SIL is the arithmetic average of the sound pressure levels in the three octave bands with centre frequencies at 500, 1 000 and 2 000 Hz.
2.43 Standardized Level Difference, D n T Difference in sound level between a pair of rooms, in a stated frequency band, normalized to a reverberation time of 0.5 s.
NOTE — Standardized level difference takes account of all sound transmission paths between the rooms (see Annex B).
2.44 Structure Borne Noise — Generation and propagation of time dependent motions and forces in solid materials which result in unwanted radiated sound.
2.45 Transient Sound — Sound which is audible for a limited period of time, for example sound from over flight of an airplane.
2.46 Third Octave Band — Band of frequencies in which the upper limit of the band is 2 ~ ~ 1 / 3 ~ times the frequency of the lower limit.
2.47 Threshold of Hearing — The lowest continuous sound pressure level which will create an auditory sensation for the average human ear. Any sound below these levels will be inaudible and any sound above the threshold will vary in loudness dependent on intensity.
2.48 Vibration Isolation — Reduction of force or displacement transmitted by a vibratory source, often attained by use of a resilient mount.
2.49 Wavelength — The length in space of one complete cycle of a sound wave.
2.50 Weighted Level Difference, D w — Singlenumber quantity that characterizes airborne sound insulation between rooms but which is not adjusted to reference conditions.
NOTE — Weighted level difference is used to characterize the insulation between rooms in a building as they are; values cannot normally be compared with measurements made under other conditions {see good practice [8-4(1)]}.
2.51 Weighted Sound Reduction Index, R _ w - Single number quantity which characterizes the airborne sound insulating properties of a material or building element over a range of frequencies.
NOTE — The weighted sound reduction index is used to characterize the insulation of a material or product that has been measured in a laboratory (see Annex B).
2.52 Weighted Standardized Impact Sound Pressure Level, L ~ n T , ~ w ~ - ~ ' Single number quantity used to characterize the impact sound insulation of floors over a range of frequencies.
NOTE — Weighted standardized impact sound pressure level is used to characterize the insulation of floors in buildings (see Annex B).
2.53 Weighted Standardized Level Difference, D n , T w Single-number quantity, which characterizes the airborne sound insulation between rooms
NOTE — Weighted standardized level difference is used to characterize the insulation between rooms in a building (see Annex B).
2.54 Weighted Normalized Impact Sound Pressure Level, L n , w ' — Single number quantity used to characterize the impact sound insulation of floors over a range of frequencies.
NOTE — Weighted normalized impact sound pressure level is usually used to characterize the insulation of floors tested in a laboratory (see Annex B).
2.55 White Noise — A noise whose spectrum (level) density is substantially independent of frequency over a specified range and has equal power for any range of frequencies of constant band width.
3 PLANNING AND DESIGN AGAINST OUTDOOR NOISE
=
10log10(pA/po)2
p A = is the A-weighted sound pressure in pascals (Pa); and
p o = is the reference sound pressure (20 μ Pa).
NOTE — Measurements of A-weighted sound pressure level can be made with a meter and correlate roughly with subjective assessments of loudness, and are usually made to assist in judging the effects of noise on people. The size of A-weighting in 1/3 octave bands, is shown in Annex A (see A-5). An increase or decrease in level of 10 dBA corresponds roughly to a doubling or halving of loudness.
2.5 Background Noise — The sound pressure levels in a given environment from all sources excluding a specific sound source being investigated or measured.
2.6 Break-in — Unwanted sound transmission into a duct from outside.
2.7 Break-out — Unwanted sound transmission from inside a duct to the outside.
2.8 Broad Band Noise — Spectrum consisting of a large number of frequency components, none of which is individually dominant.
2.9 Cross-Talk — Unwanted sound transmission between one room and another room or space via a duct.
2.10 Decibels — Ten times the logarithm (to the base 10) of the ratio of two mean square values of sound pressure, sound power or sound intensity. The abbreviation for ‘decibels’ is dB.
2.11 Effective Perceived Noise Level in Decibel (EPN dB) — The number for rating the noise of an individual aircraft flying overhead is the effective perceived noise level in decibels (EPN dB). The effective perceived noise decibel value takes into account the subjectively annoying effects of the noise including pure tones and duration. In principle, it is a kind of time-integrated loudness level.
2.12 Equivalent Continuous A-Weighted Sound Pressure Level, L A e q . T — Value of the A-weighted sound pressure level in decibels (dB) of a continuous, steady sound, that within a specified time interval, T, has the same mean squared sound pressure as the sound under consideration that varies with time, given by the formula:
p A ( t ) = is the instantaneous A-weighted sound pressure in pascals (Pa); and
p _ 0 = is the reference sound pressure (20 μ Pa).
NOTE — Equivalent continuous A-weighted sound pressure level is mainly used for the assessment of environmental noise and occupational noise exposure.
2.13 Equivalent Sound Absorption Area of a Room, A — Hypothetical area of a totally absorbing surface without diffraction effects, expressed in square metres (m2) which, if it were the only absorbing element in the room, would give the same reverberation time as the room under consideration.
2.14 Facade Level — Sound pressure level measured 1 m to 2 m in front of the façade.
NOTE — Facade level measurements of L _ p A are usually 2 dB to 3 dB higher than corresponding free-field measurements.
2.15Free-Field Level — Sound pressure level measured outside, far away from reflecting surfaces.
NOTE — Measurements made 1.2 m to 1.5 m above the ground and at least 3.5 m away from other reflecting surfaces are usually regarded as being free-field measurements. To minimize the effect of reflections the measuring position should be at least 3.5 m to the side of the reflecting surface (that is, not 3.5 m from the reflecting surface in the direction of the source). Estimates of noise from aircraft overhead usually include a correction of 2 dB to allow for reflections from the ground.
2.16 Frequency — The number of cyclical variations per unit time. Frequency is generally expressed in cycles per second (cps) and is also denoted as Hertz (Hz).
2.17 Impact Sound Pressure Level, L i ~ — ~ A v e r a g e sound pressure level in a specific frequency band in a room below a floor, when it is excited by a standard tapping machine.
2.18 Indoor Ambient Noise — Pervasive noise in a given situation at a given time, usually composed of noise from many sources, inside and outside the building, but excluding noise from activities of the occupants.
2.19Insertion Loss $( L { mathrm { bf { bar { L } } } } )$
Insertion loss is generally defined as the difference, in decibels, between two sound pressure levels (or power levels or intensity levels) which are measured at the same point in space before and after a muffler or any other noise control device is inserted between the measurement point and the noise source.
2.20 Noise — Unwanted sound which may be hazardous to health, intrerferes with communications or is disturbing.
2.21 Noise Exposure Forecast (NEF) — The noise exposure forecast at any location is the summation of the noise levels in EPN dB from all aircraft types, on all runways, suitably weighted for the number of operations during day time and night time.
2.22 Noise Rating (NR) — Graphical method for rating a noise by comparing the noise spectrum with a family of noise rating curves.
NOTE — Noise rating is described in Annex C.
Planning against noise should be an integral part of town and country planning proposals, ranging from regional proposals to detailed zoning, and threedimensional layouts and road design within built-up areas. Noise nuisance should be fully recognized in zoning regulations.
3.1.1 Noise is either generated by traffic (road, rail and underground railway) or it arises from zones and buildings within built-up areas (industry, commerce, offices and public buildings). For planning, the noise
survey should examine all the possible causes of noise and consider the various factors causing actual nuisance.
3.1.2 Noise by night, causing disturbance of sleep, is more of nuisance than noise by day. For this reason, housing colonies that adjoin areas with heavy traffic movement during the night are liable to cause serious complaints. Also, the factories that work by night are liable to cause serious complaints if housing estates adjoin them. While planning, care should be taken that housing colonies are adequately setback from busy airports, state and national highways, factories, main railway lines and marshalling yards.
3.1.3 There are two aspects of defence by planning. The first is to plan so as to keep the noise at a distance. Under this aspect comes the separation of housing from traffic noise by interposing buffer zones, and the protection of schools and hospitals by green belts, public gardens, etc. The second is the principle of shading or screening. This consists of deliberately interposing a less vulnerable building to screen a more vulnerable one or by providing a solid barrier, such as a wall, between the source and the location to be protected.