(1)Ramps with Gradients
Where ramps with gradients are necessary or desired, they shall conform to the following requirements (see Fig. 2).
(a) A ramp when provided should not have a slope greater than 1 in 20 or maximum of 1 in 12 for short distance up to 9000mm.
(b) A ramp shall have handrails on at least one side, and preferably two sides, that are 900mm high, measured from the surface of the ramp, that are smooth, and that extend 300mm beyond the top and bottom of the ramp. Where major traffic is predominantly children, the handrails should be placed 760mm high.
Notes:
(i) Where handrails are specified to be of heights other than 80cm, it is recommended that two sets of handrails be installed to serve all people.
(ii) Where major traffic is predominantly children, particularly physically disabled children extra care should be exercised in the placement of handrails, in accordance with the nature of the facility and the age group or groups being serviced (see also 94. Buildings).
(iii)Care should be taken that the extension of the handrails is not in itself a hazard. Extension up to 300 mm may be made on the side of a continuing wall.

(c) A ramp shall have a surface that is non-slip surface and if length is 3500mm, the minimum width shall be 1500mm.
(i) The provision of non-slip surfaces on ramps greatly assists the challenged persons with semi ambulatory and ambulatory disabilities. Non-slip surfaces are provided by many finishes and materials.
(ii) The surfaces of the concrete ramps can be made nonskid by brooming the surface or by finishing with an indenting roller.
(d) A ramp shall have a level platform at the top which is at least 1800mm long, if a door swings out onto the platform or toward the ramp. This platform shall extend at least 300mm beyond each side of the doorway (see Fig.3).

(e) Each ramp shall have at least 1800mm of straight clearance at the bottom.
(f) Ramps shall have level platforms at 10m to 12m intervals for purposes of rest and safety, and shall have platforms minimum 1.5m length wherever they turn.
(g) For visually impaired people, ramps may be colour contrasted with landing.
(h) To minimize rise to wheelchair users, ramps should be equipped with herbs approximately 50 mm high at exposed sides.
(2)Entrances
(a) At least one primary entrance to each building shall be usable by individuals in wheelchairs (see Fig.4A) and shall be indicated by a sign (see Fig.4B).

(b) At least one entrance usable by individuals in wheelchairs shall be on a level that would make the elevators accessible.
(3)Corridor connecting the entrance/exit
The corridor connecting the entrance/exit leading directly outdoors to a place where information concerning the overall use of the specified building can be provided to visually impaired persons either by a person or by signs, shall be provided as follows:
(a) Guiding floor materials' shall be provided or device that emits sound to guide visually impaired persons.
(b) The minimum width shall be 1500mm.
(c) In case there is a difference of level, slope ways shall be provided with a slope of 1:12.
(d) Handrails shall be provided for ramps/slope ways.
(4)Doors and Doorways