19.1.1 Main Building : The height of plinth of a building or out house, including the floor surface of a stilt floor, shall not be less than 60 cm above both, the surrounding
R T, , T , 3 3-, R/ R-, 3
ground level and the road/roads abutting the site, and shall ensure adequate.drainage of the site. In areas subject to flooding, the height of the plinth shall be at least 60 cm. above the high flood level. In the case of a storage building, the plinth height shall be that required for loading purposes.
19.1.2 Interior Courtyards/ Inner Chowks: - Every interior Courtyard shall be raised at least 15 cm. above the surrounding ground level and shall be satisfactorily drained.
19.2.1 Size and Width : - The minimum size and width shall be as given in Table 8 hereunder.
| Sr. No. | Occupancy | Minimum size (sqm) | Minimum width (m) |
| (1) | (2) | (3) | (4) |
| 1 | Any habitable room | 9.5(other than those provided for below in this table and in Notes) | 2.4 |
| 2. | Single-roomed tenement | 12.5 | 2.4 |
| 3. | Rooms in a two-room tenement - (a) one of the rooms (b) other room | 9.57.5 | 2.42.4 |
| 4. | Rooms in a two-room tenement of a site and services project - (a)one of the rooms (b)other room | 9.35.6 | 2.42.3 |
| 5. | Single-bedded room in a hostel of a recognised educational institution | 7.5 | 2.4 |
| 6. | Shop | 6.0 | |
| 7. | Class room in an educational building | 38.0 or area at the rate of 0.8 sqm per student, whichever is more | 5.5 |
| 8. | Institutional building - (a) special room (b) general ward | 9.540.0 | 3.05.5 |
| 9. | Cinema hall, theatre, auditorium, assembly hall, etc. | In conformity with the Maharashtra Cinema Rules | |
Note : - (i) An additional bedroom for occupancy of a single person shall be of a size of 5.5 sqm with a minimum width of 1.8 m.
(ii) Other requirements - One full side of a habitable room must abut an exterior open space or an inner chowk as provided in Regulation 17.2.1.
ER , - , , 3 3-, R/ -, 3
19.2.2 Height : - The minimum and maximum height of a habitable room shall be as given in Table 9 below.
| Serial No. | Occupancy | Minimum height (m) | Maximum Height (m) |
| (1) | (2) | (3) | (4) |
| 1 | Flat Roof - | ||
| (a) Any habitable room | 2.75 | 4.2 | |
| (b) Habitable room in High Density Housing | 2.6 | 4.2 | |
| (c) Air-conditioned habitable room | 2.4 | 4.2 | |
| (d) Assembly halls, residential hotels of 3-star category and above, institutional, educational, industrial, hazardous or storage occupancies, department stores, entrance halls and lobbies to department stores and assembly halls | 3.6 | 4.2greater height may be permitted subject to written permission of the Chief Executive Officer, MIDC. | |
| 2 | Pitched Roof - | ||
| (a) Any habitable room | 2.75 average 2.1 at the lowest point | 4.2 average 3.2 at the lowest point | |
| (b) Habitable room in High Density Housing | 2.6 average 2.0 at the lowest point | 4.2 average 3.2 at the lowest point | |
Notes: (i) The minimum clear headroom under any beam shall be 2.4 m.
(ii) Room for ITE or any telematic equipment can have a height as required for effective functioning of that system.
(iii) In all occupancies, except those included in serial no. 1(d) in the Table 9 above, any height in excess of 4.2 m. shall be deemed to have consumed an additional F.S.I. of 50 per cent of the relevant floor area.
19.3.1 Size : The area of the kitchen shall not be less than 3.3 sq. m. with a minimum width of 1.5 m.
19.3.1.1 No provision for kitchen is necessary in a scheme of single-roomed tenements (item 2 in Table 8). However, an alcove (a cooking space having direct access from the main room without any inter-communicating door) of a size not less than 2.4 sqm with a minimum width of 1.2 m shall be provided.
ER T, T- a , T , 3 3-, RO/ -, T 3
19.3.2 Height : The room height of a kitchen measured from the surface of the floor to the lowest point in the ceiling (bottom of slab) shall not be less than 2.75 m or according to item 2 in Table 9.
19.3.3 Other Requirements : Every room to be used as a kitchen shall have -
(a) Means for washing of kitchen utensils, which shall lead directly or through a sink to grated and trapped connection to the waste pipe;
(b) Impermeable floor;
(c) A window of not less than 1.0 sq. m. area, opening directly on to an inner or outer chowk, but not into a ventilation shaft; and
(d) Refuse chutes, in the case of multi-storeyed residential buildings more than 24 m in height.
(i) Size: - The floor area of a store-room in a residential building, where height, light and ventilation are provided at a lower standard than those required for a living room, shall not be more than 3 sqm.
(ii) Height: - The height of a store-room shall not be less than 2.10 m.
19.7 Garage: In addition to regulation no. 17.4.1 (e), the following shall apply:
(i) The area of parking lock-up garage shall be included in F.S.I. calculations.
(ii) Size: - The size of a garage in individual residential building shall not be less than 2.5 m X 5 m. and not more than 3 m X 6 m.
(iii) Height: - The maximum headroom in a garage shall be 2.4 m.
(iv) The plinth of garage located at ground level shall not be less than 15 cm above the surrounding ground level.
(v) The garage shall be set back behind the building line for the street / road on to which the plot abuts and shall not be so located as to affect the access ways to the building.
(vi) Corner Site: When a plot fronts on two intersecting streets, the location of the garage, if proposed within the marginal open spaces, shall be diagonally opposite the point of intersection.
(vii) No garage shall be permitted in a building having stilt or basement provided for parking.
19.4.1 Size - The minimum size shall be as under - (a) Independent Bathroom 1.0 m x 1.2 m (b) Independent Water Closet 0.9 m x 1.2 m
(c) Combined Bathroom and Water Closet 1.8 sqm with minimum width of 1.0 m.
19.4.2 Height - The Height of any bathroom or water closet shall not be less than 2.1 m.
19.4.3 Other Requirements - Every bathroom or water closet shall -
(a) be so situated that at least one of its wall shall open to external air with the size of opening (windows, ventilators, louvers) not less than 0.3 sqm in area and side not less than 0.3 m (See Regulation No. 19.10.3) ;
(b) have the platform or seat made of water tight non-absorbent materiall ;
(c) be enclosed by walls or partitions, the surface of which is finished with a smooth impervious material to a height of not less than 1 m above the floor of such a room ;
(d) be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards verandah or any other room ;
(e) be used for any purpose other than as a lavatory and shall not open directly into any kitchen or cooking space by a door, window or other opening; and
(f) shall have a door completely closing the entrance to it.
19.5 Cupboards & Shelves - Cantilevered projections of cupboards and shelves may be permitted except on ground floor and would be exempted from covered area and built up area calculations. Such projections may project up to 45 cm in the setbacks for residential buildings provided the width of such cupboard/shelves does not exceed 2.4 m and each
R , , T , 3-, 2/ -,
room does not have more than one such cupboard/ shelf. Such projection shall be at least 2 m from plot boundary.
19.9.1 Basement shall be constructed within the prescribed setbacks and prescribed building line in plots up to 2000 sqm and in plots above 10,000 sqm in area. In plots between 2000 sqm and 10,000 sqm in area, a clear margin of 6 m shall be kept between outer wall of basement and plot boundary for facilitating easy movement of fire engine. Basements can be constructed in one or two levels. Multi-level basements may be permitted only if used for parking. Basements may be put to only following non-habitable uses: -
(a) Uses permissible : -
(i) Air conditioning equipment and other machines used for services and utilities of the building ;
(ii) Parking spaces ;
(iii) Strong room, bank cellars etc.
(iv) Storage of household or other goods of ordinarily noncombustible material;
(v) Electric sub-station (which will conform to required safety requirements); and
(vi) uses strictly ancillary to the principal use.
Provided that, uses strictly ancillary to the principal use shall be permissible in a basement.
Provided further that, prior written permission from the Authority shall be obtained where the basement is used for storage purpose.
(b) The basement shall not be used for any habitable uses.
19.9.2 Apart from the Fire Protection Requirements, The basement shall have the following requirements : -
(a) Height: The height of a basement from the floor to the underside of the roof-slab or ceiling or under side of a beam, when the basement has a beam, shall not be less than 2.4 m.
(b) Ventilation: Adequate ventilation shall be provided for the basement with a ventilation area not less than 2.5% of the area of the basement. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems etc.
(c) Height above ground level: The ceiling of basement partially below ground level shall be at least 0.9 m and not more than 1.2 m above the average surrounding ground level. Mechanically ventilated basements can be fully underground.
(d) Drainage : Adequate arrangement shall be made such that surface water does not enter the basement.
ER T, - , T , 3 3-, R0/ -, 93
(e) Damp proofing : The walls and floor of the basement shall be watertight and be so designed that the effect of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given; and
(i) The access to the basement shall be separate from both, the main and alternate staircase providing access and exit from higher floors. In case the building is served by more than one staircase, one of the staircases can be continuous and shall be of enclosed type serving as a fire separation from the basement floor and higher floors [see Regulation No. 21.4.(I) (m) for stairways]
(ii) Open ramps may be permitted if they are constructed within the building line subject to the provision of (d).
(g) For plots up to 2000 sqm, two ramps shall preferably be provided for parking spaces in basements and upper floors. For plots above 2000 sqm, it shall be mandatory to provide at least two separate ramps preferably at opposite ends. The number of ramps required shall be decided on travel distance (see Table 11). The ramps shall have minimum width of 3.5 m for one-way operation and 6.0 m for two-way operation. Such ramps may be permitted in the side and rear marginal open spaces after leaving a 6.0 (six) meter wide space for movement of fire fighting vehicles.
(i) The roof of a building shall be so constructed or framed as to permit effective drainage of the rainwater therefrom by means of sufficient rainwater pipes of adequate size, so arranged, jointed and fixed as to ensure that the rainwater is carried away from the building without causing dampness in any part of the walls or foundations of the building or those of an adjacent building.
(ii) The Authority may require rainwater pipes to be connected to a stormwater drain through a covered channel formed beneath the public footpath or in any other approved manner, if not used for rain water harvesting.
(iii) Rainwater pipes shall be affixed to the outside of the walls of the building or in such other manner as may be approved by the Authority.
(iv) Terrace of a building shall not be sub-divided and it shall have only common access.