Chapter 3Land Use Classification and Permissible Uses
24.0 General
The land ownership of Integrated Industrial Areas (IIAs), unlike that in a normal urban area, entirely vests in one entity and as such, the Development Plan of the Special Planning Authority will be in a position to distinctively earmark space for day-to-day needs of the residents in a planned manner instead of the conventional practice of differentiating between a purely residential zone and a residential zone where several other land uses are also allowed to be mixed on the basis of the width of road on which a property fronts.
Thus, the conventional practice of classifying the residential use in to two classes may not be banked upon. Instead, the Development Plan may earmark, within the residential zone, distinctive spaces for non-residential support activities required by residents in a hierarchical manner in the form of Neighbourhood Centres, Sub-City Centres and City Centre depending upon the size of the IIAs. A set of clusters of such uses may be planned in such a manner that the farthest distance from a nearest cluster is within a walking distance of 500 to 1000 m.
Thus, there could be a centre that accommodates only service industries, another that caters to day-to-day needs and some others catering to other needs such as shops, restaurants, offices of professionals, clinics etc. These centres can be planned in such a manner that they are encircled by at least 15 m wide roads to segregate them from the surrounding residential use. They should adequately cater for associated parking and loading-unloading needs.
Such arrangement of centres will not only ensure safe, healthy, quiet and attractive residential neighbourhoods but will impart enviable efficiency to non-residential uses also. Other public needs such as health, education and recreation facilities etc. which require larger area, can be located in independent plots clearly designated as such in Development Plan.
This type of development pattern is termed as Model-I Type Development.
Alternatively, if, because of constraints on the extent of land available or, for reasons of taste, the ’Developer’ opts for the conventional practice of R1 and R2 zones within residential zone, he may propose mixed land use system subject to following restrictions: -
ER , - , , 3 3-, R/ -, 3
a. The mixed use development may be confined to roads which are not the main arteries of IIA (i.e. widths of roads 24 m and above) and are not proposed on roads narrower than 15 m in width ;
b. The mixed-use development should be confined to ground, first and, in exceptional cases, second floor ;
c. The extent of non-residential uses in the aggregate shall not exceed the stipulated one fourth of the area of the support activities ;
d. Access to residences shall be separate from those for other uses ; and
e. Parking for residential use shall be separately provided with independent entry-exit.
This type of development pattern is termed as Model-II Type Development.
Intermixture of these two models of development shall not be permissible.
The classification of different land uses and different uses permissible in a specific land use, clusters and independent plots are given below.
24.1Model-I Type Development
24.1.1 The following uses and accessory uses to the principal use of residences shall be permitted in buildings or premises in Residential Zone :
(i) Customary Home occupations, i.e. occupations customarily carried out by the members of a household without employing hired labour and includes stitching embroidery, button making etc. with or without motive power. If motive power is used, the total electricity load should not exceed 1 H. P.
(ii) Accessory uses customarily incidental to use of a residence including storage space, up to 50 percent of the total floor area used for the residence.
24.1.2 Clusters of Facilities in Neighbourhood Centres, Sub-City Centres and City Centre: - Clusters for Class A Service Industries within different levels of Centres shall be planned independently of the uses like shops for day-to-day needs, other types of shops, offices and other facilities required by residents. The hierarchical type and levels of activities to be arranged within different Centres is indicated below: -
(可.何..)--
Note: The main fire station may be located in the industrial area.
C2
HERT T, - , T R, 3 3-, RO/ R-, T 3
Hierarchical System of Centres
Criteria for Essential Activities
Neighbourhood Centre
Sub-City Centre
City Centre
Accessibility (km)
0.5 to 1.0
2.0 to 3.0
Minimum Area (ha)
0.5
2.0
5.0
Social and Commercial Activities
Retail Shopping, Professional/ Commercial Offices, Local level service outlets. Note: Individual activity outlet not to occupy area more than 20 sqm.
Retail Shopping, Professional/ Commercial and other Offices, Cinema/ Multiplexes, Hotels, Restaurants, Banquet Halls, Socio-Cultural activities, Recreational activities, Police Post, Fire Sub-Station. Telephone Exchange, Post and Telegraph Sub-Office, Petrol Pump/ CNG station, Bus Shelter, Parking.
Retail Shopping, Professional/ Commercial and other Offices, Cinema/ Multiplexes, Hotels, Restaurants, Banquet Halls, Socio-Cultural activities / Recreational activities/ Club, Police Station, Fire Station. Telephone Exchange, Post and Telegraph Office, Radio Broadcasting Station and Studios, Petrol Pump/ CNG station, Bus Terminal, Multi level Parking.
Health Activities
Clinical Laboratory, Clinic.
Clinical/ other Laboratory, Clinic/ Polyclinic, Maternity, surgical and other hospitals (below 20 beds).
Clinical/ other Laboratory, Clinic/ Polyclinic, Maternity, surgical and other hospitals.
Service Industries Class-A.
Segregated cluster of service industries Note: Individual activity outlet not to occupy area more than 20 sqm.
Segregated cluster of service industries Note: Individual activity outlet not to occupy area more than 50 sqm.
Segregated cluster of service industries Note: Individual activity outlet not to occupy area more than 50 sqm.
Note: (i) The Authority shall exercise judgment while deciding the nature and level of activities to be permitted from the point of view of compatibility with other activities and the level of the centre.
(iii) Such centres shall not accommodate any residential use.
The norms for provision of Fire Services Establishment shall be on the following lines : -
Type
Distance Norm (km)
Area Norm (ha)
(i) Fire Station with essential residential accommodation
5 to 7
1.0
(ii) Sub Fire Station with essential residential accommodation
1 to 3
0.6
24.1.3 The activities that are not covered in the Clusters for Class A Service Industries or in different levels of Centres shall be arranged in to earmarked uses and in independent plots as given in Error! Not a valid bookmark self-reference. below.
ER , - , , 3 3-, R/ -, 3
C3
Table 14Facilities in Earmarked and Independent Plots
Earmarked Uses
Independent Plots
Primary and nursery schools including students' hostels, Colleges, Secondary Schools, Trade or other similar schools.
Veterinary dispensaries and Veterinary hospitals
Parks, gardens, Playgrounds and Fair and Exhibition Grounds
Religious Buildings
Burial grounds, cremation grounds
Electric sub-stations, Pumping stations and Water Installations, essential Public Utilities
Animal pounds
Star category Hotels
Notes :--
(a) As roads with 24 m width and above along with classified roads (except village roads) are treated as arterial roads, uses other than residences on such roads will conflict with the mobility function of these roads. No such Centres of other uses shall, therefore, be permitted on these roads. However, if frontage/service roads are provided along side such arterial roads to facilitate access to adjoining properties, the aforesaid Centres of other uses may then be allowed to front on such service roads, locally widened to 15 m to accommodate both, the increased pedestrian activity and vehicular parking of visitors in a parking lay-by.
(b) The Centrsshall be segregated from surrounding residential zone by 15 m wide roads or layout open spaces.
(c) All goods offered for sale and brought for repair shall be displayed and kept within the building and shall not be kept in the passages or footpaths or roads.
(d) Stores, trade and business involving any danger of fire, explosion, offensive noise, vibrations, smoke, dust glare heat or other objectionable influence may be allowed with the approval of the Authority.
(e) Any other use may be allowed in consultation with the Director of Town Planning, Maharashtra State in accordance with the intent and spirit of these Regulations.
24.1.4 Clusters of Class A Service Industries : - The units of Class A Service Industries may be permitted in independent clusters within the Centres with limitation of area, maximum number of persons to be employed, maximum permissible power and special conditions, if any, as given in Error! Reference source not found. for Class A Service Industries.
24.1.5 Industries and Class B Service Industries : - Industries and Service Industries Class-B shall be those as appear in ‘Principal Regulations’ and shall be permitted according to those regulations in industrial zone.
7 (.何..)----3
∠2
महाराष्ट्र श्रामन राजर्ण, भाग एक-नोकॉष विश्तानोपे पूरवाधी, पृथ्यार से तुकृमां, अभिकर 13-29, 2024/आयण 22-25, एजो 19936
Table 15Schedule for Class A Service industries
Sr. No.
Category of industry
Service Industry Class -A (Permitted in Independent Clusters In Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(in H.P.)
Max.Permissible employment(in persons)
Max.Permissible floor area(in sq. m.)
Special Conditions, If any
(1)
(2)
(3)
(4)
(5)
(6)
1.
Food Products
1.
Preservation of meat,canning, preserving andprocessing of fishcrustaceous and similartfoods.
Not Included
2.
Manufacture of milk anddairy products such asbutter, ghee etc.
10
9
50
3.
Canning & preservationof Fruits & Vegetablesincluding production ofJam, Jelly, Sauce, etc.
Not Included
4.
(a) rice nuller
10
9
50
(b) Groundnutdecorricators
10
9
50
(c) Grain Mill forproduction of flour
10
9
50
पाह्ट्रेष्ट्र शनम राजन, भाग एक-रोलगण विभारीय पुरुदापी, पूरुषार से चुष्कार, प्रोगनट १३-१९, ६०१५/श्राणा १३-२८, जोके १९२७
४१
Sr. No.(1)
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(in H.P.)
Max Permissible employment(in persons)
Max.Permissible floor area(in sq. m.)
Special Conditions, if any
(2)
(3)
(4)
(5)
(6)
(d) Manufacture of superi and Masala grinding (in separate building)
10
9
50
-
(e) Baby oil expellers
10
9
50
-
5.
Manufacture of bakery products with no Floor above
10
9
75
(i) Fuel used shall be electricity, gas or smokeless coal.(ii) Where only electric oven is used, an additional heating load of 24 KVA permitted per establishment.
6.
Manufacture of cocoa, chocolate, Sugar confectionary
Not Included
7.
Coffee, curing roasting and grinding
2
9
50
-
8.
Cashew nut processing like drying, decorticating, roasting, salting etc.
Manufacture of leather or leather processing not permitted.
29.
Manufacture of wearing apparel like coats, gloves etc.
5
9
50
महानाष्ट्र जसमर राजन्द्र, भाग एक-कोकण विमायोय पूरुपानी, मुचनार ते कुंगोराग, ऑस्टल १३-११, २०२५/माश्रण २२-२८, सर्ट १९३६
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(in H.P.)
Max Permissible employment(in persons)
Max.Permissible floor area(in sq. m.)
Special Conditions, if any
(1)
(2)
(3)
(4)
(5)
(6)
30.
Manufacture of leather consumers goods such as upholstery suitscases pocket books, cigarette and key cases, purses etc.
5
9
50
31.
Repair of footwear and other leather
5
9
50
VII.
RUBBER AND PLASTIC
32.
Re-treading and vulcanizing works
2
9
50
33.
Manufacture of rubber balloons, hand gloves and allied products
2
9
50
VIII.
NON-METALLIC MINERAL PRODUCTS
34.
Manufacture of structural stone goods, stone dressing, stone crushing and polishing
Not Included
35.
Manufacture of carthen & plaster states and images, toys and art wares.
Not Included
गण रत्त (कां.नि गु.)-12
0
माराताष्ट्र शालनं (भोभू, भाप एक-आकृष दिगारिव पुरुद्धी, गुणवार से जुपकास, ऑस्ट ६३-२९, २०९९/आभग ६२-२८, शके ११३७.
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(in H.P.)
Max Permissible employment(in persons)
Max.Permissible floor area(in sq. m.)
Special Conditions, If any
(1)
(2)
(3)
(4)
(5)
(6)
36.
Manufacture of cement concrete building components, concrete grills, septic tank, Plaster of Paris work, lime mortar etc.
Not Included
37.
METAL PRODUCTS
38.
Plating, Polishing and buffing of metal products
Not Included
39
Manufacture of metal building components such as grills, gates, Doors and window frames, water tanks, wire nets, etc.
5
9
50
नुपान्द्र असने संचना, भाग एक-कोरूज विभगीव मुख्यों, गुल्तार ने मुख्यार, औरमट १६-१९; २०५९.अकाणा २३-२८, शके १९३०
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(in H.P.)
MaxPermissible employment(in persons)
Max.Permissible floor area(In sq. m.)
Special Conditions, if any
(1)
(2)
(3)
(4)
(5)
(6)
40.
Manufacture and repair of sundry ferrous engineering products done by jabbing concerns such as mechanical works, shops with lathes, drills, grinders, welding equipment etc.
No. Included
41.
Tool sharpening and razor sharpening works
1
6
23
X.
ELECTRICAL GOODS
42.
Repairs of household electrical appliances such as radio set, Television set, tape recorders, heaters, irons, shavers, vacuum cleaners, refrigerators, air-conditioners, washing machines, electric cooking ranges, motor rewinding works, etc.
3
9
50
(i) No spray painting permitted.
གྲུ་རེ (ཞོ་ཞེ་ཀྱོ) — འཕྲས
?
महालन्द्र जोलन राजस्थ, ५३१ एक-शिकभ विभानीय पुरुतामी, मुल्लार ने कृथवार: ऑमट २३-१९, २०१५/आगमा २३-२८, असे २१३६
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(In H.P.)
Max Permissible employment(in persons)
Max.Permissible floor area(in sq. n.)
Special Conditions, if any
(1)
(2)
(3)
(4)
(5)
(6)
XL
TRANSPORT EQUIPMENT
43.
Manufacturing of push cart, hand cart, etc.
Not Included
44.
(a) Servicing of motor vehicles and motor cycles.
10
9
50
(b) Repair of motor vehicles and motor cycles.
10
9
50
(i) No spray painting permitted
(c) Battery charging and repairs.
5
6
23
45.
Repairs of bicycles and cycle rickshaws.
5
6
50
XII.
OTHER MANUFACTURING AND REPAIR INDUSTRIES AND SERVICES
46.
Manufacture of jewellery and related articles
3
9
50
47.
Repairs of watches, clocks and jewellery
3
9
50
48.
Manufacture of sports and athletic goods
Not Included
49.
Manufacture of Musical instruments and their repair.
3
9
50
ष्टादाष्ट्र प्राकन नगत्तर, भाग एक-बोकण विभारीप पूल्यर्ष, पुरुकाह ने यृष्कास, औराष २४-११, ६०५९/स्वाणय १-०-८; सम्फे १२३७
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Max.Permissible Power(in H.P.)
Max Permissible employment(in persons)
Max.Pennissibl floor area(in sq. m.)
Special Conditions, if any
(1)
(2)
(3)
(4)
(5)
(6)
50.
Mass manufacture of miscellaneous products such as costume, jewellery, costume novelties, feather, plumes, artificial flowers, brooms, brushes, lamp shades, tobacco, pipes, cigarette holders, ivory goods, bandages, wigs and similar articles.
Not Included
51
(a) Repairs of locks, stoves, umbrellas, sewing machines, gas burners, buckets & other sundry household equipment.
3
9
50
(b) Optical glass grinding and repairs
3
8
50
52.
Manufacture of gas in gas work and distribution.
10
9
9Y
Sr. No.
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or In R2)Criteria for Classification and special conditions
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or In R2)Criteria for Classification and special conditions
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or In R2)Criteria for Classification and special conditions
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or In R2)Criteria for Classification and special conditions
Sr. No.
Sr. No.
Category of Industry
Max.Permissible Power(in H.P.)
Max Permissible employment(in persons)
Max.Permissible floor area(in sq. m.)
Special Conditions, if any
(1)
(1)
(2)
(3)
(4)
(5)
(6)
53.
(i) Filling Stations of Petrol, Diesel, Compressed Natural Gas stations and/or any other motor vehicle fuel in plot size of 30.5 m x 16.75 m
(i) Filling Stations of Petrol, Diesel, Compressed Natural Gas stations and/or any other motor vehicle fuel in plot size of 30.5 m x 16.75 m
(a) 15(b) 30 per compress or (not more than 3 compressors)(c)150 per compress or (not more than 3 compressors)
(a) 9
No Limit
Plot size to be in line with L.R.C. recommendations depending on service bay or not for Petrol and Diesel Filling or Filling cum Service Centre.(i) Quantities in (b) or (c) of columns (3) and (4) will be permitted for daughter booster pumping station and on-line pumping station respectively over (a).(ii) Permissible power mentioned in (b) & (c) in column (3) will be used exclusively for compressing and filing gas in vehicles.(iii) Special permission from Authority is necessary after clearance by the Maharashtra Pollution Control Board from noise pollution point of view and controller of Explosive and Chief Fire Officer and observance of such conditions as they may prescribe.
53.
(ii) Filling and Service Stations, of Petrol, Diesel, Compressed Natural Gas Stations and/or any other motor vehicle fuel in plot size of 36.5 m x 30.5 m
(ii) Filling and Service Stations, of Petrol, Diesel, Compressed Natural Gas Stations and/or any other motor vehicle fuel in plot size of 36.5 m x 30.5 m
(a) 15(b) 30 per compress or (not more than 3 compressors)(c)150 per compress or (not more than 3 compressors)
(b) 6
No Limit
Plot size to be in line with L.R.C. recommendations depending on service bay or not for Petrol and Diesel Filling or Filling cum Service Centre.(i) Quantities in (b) or (c) of columns (3) and (4) will be permitted for daughter booster pumping station and on-line pumping station respectively over (a).(ii) Permissible power mentioned in (b) & (c) in column (3) will be used exclusively for compressing and filing gas in vehicles.(iii) Special permission from Authority is necessary after clearance by the Maharashtra Pollution Control Board from noise pollution point of view and controller of Explosive and Chief Fire Officer and observance of such conditions as they may prescribe.
HER , - , T , 3 3-, R0/ R-, T 39
53.
(iii) Filling stations of only Compressed Natural Gas Minimum area of plot 300 sqm
(iii) Filling stations of only Compressed Natural Gas Minimum area of plot 300 sqm
(a) 15(b) 30 per compress or (not more than 3 compressors)(c)150 per compress or (not more than 3 compressors)
(c) 6
No Limit
Plot size to be in line with L.R.C. recommendations depending on service bay or not for Petrol and Diesel Filling or Filling cum Service Centre.(i) Quantities in (b) or (c) of columns (3) and (4) will be permitted for daughter booster pumping station and on-line pumping station respectively over (a).(ii) Permissible power mentioned in (b) & (c) in column (3) will be used exclusively for compressing and filing gas in vehicles.(iii) Special permission from Authority is necessary after clearance by the Maharashtra Pollution Control Board from noise pollution point of view and controller of Explosive and Chief Fire Officer and observance of such conditions as they may prescribe.
54.
Laundries, Laundry service and cleaning, dyeing, bleaching and dry cleaning
Laundries, Laundry service and cleaning, dyeing, bleaching and dry cleaning
5
9
50
(i) Cleaning & dyeing fluid used shall not have flash point lower than 59°C.(ii) Machinery having dry load capacity of 20 kg and above.
55.
Photo processing laboratories
Photo processing laboratories
5
9
50
Sr. No.
Sr. No.
Category of Industry
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Service Industry Class -A (Permitted in Independent Clusters in Residential Zone or in R2)Criteria for Classification and special conditions
Sr. No.
Sr. No.
Category of Industry
Max. Permissible Power (in H.P.)
Max Permissible employment (in persons)
Max. Permissible floor area (in sq. m.)
Special Conditions, if any
(1)
(1)
(2)
(3)
(4)
(5)
(6)
56.
Electronic Industry of assembly type (and not of manufacturing type including heating lead).
Electronic Industry of assembly type (and not of manufacturing type including heating lead).