The plot size and requirements for various use occupancies shall be as follows.
| Sl. | Use Occupancies | Min. Plot Size (sq.m.) | Min. Existing Road width (m) |
| I | Residential | See Chapter-4 for details | |
| 1 | Plotted - Single/Multi Unit | 40 (Row Housing - Single Unit) No minimum plot size in built-up area | 7.5 (plots on one side) 9 (plots on both sides) 4.0 m (Built-up area) |
| 1 | Plotted - Single/Multi Unit | 150 (Row Housing - Multi Unit) | 9 |
| 1 | Plotted - Single/Multi Unit | 500 (Semi-detached) | 9 |
| 1 | Plotted - Single/Multi Unit | 1200 (Detached) | 9 |
| 2 | Group Housing | 1000 (Built-up) 1500 (Non-built-up) | 9 (Built-up area) 12 (Non-Built-up area) |
| II | Commercial/ Office Buildings | See Chapter-5 for details | |
| 1a | Retail Shops | >10 to 100 | 6 (Built-up) 9 (Non-built-up) |
| 1b | Convenient Shopping / Commercial Units | >100 - 300 | 12 |
| 2 | Commercial Complex | >300 - 3000 | 12 |
| 3 | Shopping mall | > 3000 | 18 |
| 4a | Hotels (<20 rooms) | Not defined | 6 (Built-up) 9 (Non-built-up) |
| 4b | Hotels (>20 rooms) | 500 | 12 |
| 5a | Single Screen Cinema | 500 | 12 |
| 5b | Miniplex | 700 | 12 |
| 5c | Multiplex | 3000 | 18 |
| 6a | Petrol Pump/ Filling Station without service station | 224 (16 x 14) -2w/3w 510 (30 x 17) | 12 (Built-up) 24 (Non-Built-up) |
| Sl. | Use Occupancies | Min. Plot Size (sq.m.) | Min. Existing Road width (m) |
| (CNG/PNG/EV) | |||
| 6b | Petrol Pump/ Filling Station with service station (CNG/PNG/EV) | 1080 (36 x 30) | 12 (Built-up) 24 (Non-Built-up) |
| 7 | LPG / Gas Godown | 520 (26 x20) | 18 |
| 8 | Service Apartment | Not defined | 12 |
| 9 | Cold Storage | 1000 | 18 |
| 10 | Warehousing/ Storage Godown | Not defined | 12 |
| 11 | Wholesale Market | Not defined | 12 |
| 12 | Office Buildings | Not defined | 12 |
| 13 | Other Commercial | Not defined | 9m (Built-up area) 12m (Non-built-up area) |
| III | Community Facilities/ PSP | See Chapter-6 for details | |
| A | Healthcare Facilities | ||
| 1 | Non-Bedded Medical Establishments (Diagnostic Centre/ OPD clinics/ dispensary/ Pathology Lab/ Veterinary Clinics) | 100 | 9 |
| 2 | Nursing Homes / Veterinary Hospitals / Maternity Hospitals/ Small Hospitals (Up to 50 beds) | 300 | 12 |
| 3 | Hospitals (> 50 beds) | 3000 | 18 |
| 4 | Nursing Institutes | 2000 | 18 |
| 5 | Medical College | As per NMC/ MCI norms | 24 |
| B | Education Facilities | ||
| 1 | Nursery | 500 | 9 |
| 2 | Primary | 1000 | 9m (Built-up area) 12m (Non-built-up area) |
| 3 | Secondary/High School/Inter College | 2000 | 12 |
| 4 | Degree College/Technical Institution | 5000 | 18 |
| 5 | Universities | 20000 | 24 |
| C | Public Amenity buildings | ||
| 1 | 750 (Built-up area) | 18 | |
| Sl. | Use Occupancies | Min. Plot Size (sq.m.) | Min. Existing Road width (m) |
| Marriage Hall/ Banquet/ Multipurpose Hall | 1000 - 3000 (Non-built up area) | 18 | |
| Marriage Hall/ Banquet/ Multipurpose Hall | >3000 | 24 | |
| 2 | Auditorium / Convention Centre | 1500 | 18 |
| 2 | Auditorium / Convention Centre | 2000 | 24 |
| D | Other Community Facilities | ||
| 1 | Religious Buildings | Not defined | 12 |
| 2 | Guest House | 400 | 12 |
| 3 | Utilities & Services | Not defined | 12 |
| 4 | Other institutional | Not defined | 12 |
| IV | Agriculture | ||
| 1 | Farmhouse | 4000 | 7 |
| 2 | Dairy Farms | 2000 | 7 |
| V | Industrial | ||
| 1 | Industrial Buildings | Not defined | 9 |
| 2 | Flatted factories | Not defined | 12 |
| 3 | Data Centers | Not defined | 12 |
| 4 | MSME | Not defined | 9 |
| VI | Mixed Use | Refer Chapter-8 | 24 |
| VII | Recreational | ||
| 1 | Stadium/ Sports Complex | Not defined | 18 |
| 2 | Amusement Park | Not defined | 18 |
| 3 | Memorial | Not defined | 9 |
| VIII | Transportation | ||
| 1 | Multi-level Parking | 800 for built-up area 1000 for non-built-up area | 12 |
| 2 | Bus Terminal | Not defined | 12 |
| 3 | Transportation Hub | Not defined | 12 |
Note: For Petrol Pump/Filling Station, in case any amendment is issued by MoPNG or any competent authority, it shall automatically prevail.
The calculation of floor area shall be conducted telescopically, beginning from one level below the area of the proposed plot.
For example, for a plot size of 100 square meters, permissible FAR is 2.0 and for plot size 100 -300 sqm, the permissible FAR is 1.75.
Calculation of FAR for a plot size of 280 square meters, shall be done as below:
a. Plot area of 280 square meters to be divided into two parts, i.e. 100 sqm + 180 sqm
b. For 100 sqm, as per applicable FAR, allowable floor area shall be 100*2.0 = 200 sqm
c. For remaining 180 sqm, as per applicable FAR, allowable floor area shall be 180*1.75 = 315 sqm
d. Hence, total allowable floor area shall be 515 sqm
The ground coverage and FAR for various use occupancies shall be as follows.
3.2.2.1 Residential – Plotted Development including EWS/ LIG/ Affordable Housing
| Sl. | Use Types | Ground Coverage (%) | Plot Area (sq.m.) | Base FAR | Max. FAR |
| 1 | Plotted Development - Single Unit/Multi-Unit (Built-up/Non-Built-up) | Max. coverage after ensuring setbacks | Up to 150 | 2.0 | 2.0 |
| >150 to 300 | 1.8 | 2.0 | |||
| >300 to 500 | 1.75 | 2.0 | |||
| >500 to 1200 | 1.5 | 2.0 | |||
| >1200 | 1.25 | 2.0 |
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9.
3.2.2.2 Residential – Group Housing including EWS/ LIG/ Affordable Housing
| Sl. | Use Types | Ground Coverage (%) | Road Width (m) | Base FAR | Max. FAR |
| 2(a) | Group Housing (Built up) | Max. coverage after ensuring setbacks | 9 - 12m | 1.5 | 2.0 |
| >12 - 18m | 1.5 | 3.0 | |||
| >18 - 24m | 1.5 | 3.0 | |||
| >24 - 45m | 1.5 | 5.25 | |||
| > 45m | 1.5 | Unrestricted | |||
| 2(b) | Group Housing (Non-Built up) | Max. coverage after ensuring setbacks | >12 - 18m | 2.5 | 5.0 |
| >18 - 24m | 2.5 | 5.0 | |||
| >24 - 45m | 2.5 | 8.75 | |||
| > 45m | 2.5 | Unrestricted |
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9
3.2.2.3 Commercial – Shops / Convenience Shopping / Other Commercial
| Sl. | Use Types | Ground Coverage (%) | Road Width (m) | Base FAR | Max. FAR |
|---|---|---|---|---|---|
| 3(a) | Shops / Convenience Shopping / Commercial Units (Built-up) | Max. coverage after ensuring setbacks | Up to 12m | 1.5 | 2.1 |
| >12 - 24m | 1.5 | 3 | |||
| >24 - 45m | 1.5 | 5 | |||
| >45m | 1.5 | Unrestricted | |||
| 3(b) | Shops / Convenience Shopping / Commercial Units (Non-Built up) | Max. coverage after ensuring setbacks | Up to 12m | 1.75 | 2.45 |
| >12 - 24m | 1.75 | 3.5 | |||
| >24 - 45m | 1.75 | 6 | |||
| >45m | 1.75 | Unrestricted | |||
| 4(a) | Commercial Complex (Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 1.5 | 3 |
| >24 - 45m | 1.5 | 5 | |||
| >45m | 1.5 | Unrestricted | |||
| 4(b) | Commercial Complex (Non-Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 1.75 | 3.5 |
| >24 - 45m | 1.75 | 6 | |||
| > 45m | 1.75 | Unrestricted | |||
| 5(a) | Shopping malls (Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 | |||
| > 45m | 2 | Unrestricted | |||
| 5(b) | Shopping malls (Non-Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 3 | 6 |
| >24 - 45m | 3 | 9 | |||
| > 45m | 3 | Unrestricted | |||
| 6(a) | Hotels (Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 | |||
| > 45m |
3.2.2.4 Community Facilities – Healthcare Buildings
| Sl. | Use Types | Ground Coverage (%) | Road Width (m) | Base FAR | Max. FAR |
| 1 | Non-Bedded Medical Establishments (Diagnostic Centre / OPD clinics / dispensary / Pathology Lab / Veterinary Clinics) | Max. coverage after ensuring setbacks | Up to 12m | 1.5 | 2.1 |
| >12 - 24m | 1.5 | 3.0 | |||
| >24 - 45m | 1.5 | 5.25 | |||
| > 45m | 1.5 | Unrestricted | |||
| 2(a) | Nursing Homes / Veterinary Hospitals / Maternity Hospitals / Small Hospitals (Up to 50 beds) (Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 1.5 | 3.0 |
| >24 - 45m | 1.5 | 5.25 | |||
| > 45m | 1.5 | Unrestricted | |||
| 2(b) | Nursing Homes / Veterinary Hospitals / Maternity Hospitals / Small Hospitals (Up to 50 beds) (Non-Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2.0 | 4.0 |
| >24 - 45m | 2.0 | 7.0 | |||
| > 45m | 2.0 | Unrestricted | |||
| 3(a) | Hospital > 50 beds (Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 1.5 | 3.0 |
| >24 - 45m | 1.5 | 5.25 | |||
| > 45m | 1.5 | Unrestricted | |||
| 4(b) | Hospital > 50 beds (Non-Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2.5 | 5.0 |
| >24 - 45m | 2.5 | 8.75 | |||
| > 45m | 2.5 | Unrestricted | |||
| 5(a) | Nursing college (Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 1.5 | 3.0 |
| >24 - 45m | 1.5 | 5.25 | |||
| > 45m | 1.5 | Unrestricted | |||
| 5(b) | Nursing college (Non-Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2.0 | 4.0 |
| >24 - 45m | 2.0 | 7.0 | |||
| > 45m | 2.0 |
3.2.2.5 Community Facilities – Education Buildings
| Use Types | Ground Coverage (%) | Road Width (m) | Base FAR | Max. FAR | |
| 1(a) | Schools (Nursery/Primary) (Built up) | Max. coverage after ensuring setbacks | Up to 12m | 1.0 | 1.4 |
| >12 - 24 m | 1.0 | 2.0 | |||
| >24 - 45 m | 1.0 | 3.0 | |||
| > 45 m | 1.0 | 3.0 | |||
| 2(b) | Schools (Nursery/Primary) (Non-Built up) | Max. coverage after ensuring setbacks | Up to 12m | 1.2 | 1.4 |
| >12 - 24 m | 1.2 | 2.4 | |||
| >24 - 45 m | 1.2 | 3.6 | |||
| > 45 m | 1.2 | 3.6 | |||
| 3(a) | Secondary/Intercollege/Degree Colleges / Universities (Built up) | Max. coverage after ensuring setbacks | =>12 - 24 m | 1.0 | 2.0 |
| >24 - 45 m | 1.0 | 3.5 | |||
| > 45 m | 1.0 | Unrestricted | |||
| 3(b) | Secondary/Intercollege/Degree Colleges / Universities (Non-Built up) | Max. coverage after ensuring setbacks | =>12 - 24 m | 2.0 | 4.0 |
| >24 - 45 m | 2.0 | 7.0 | |||
| > 45 m | 2.0 | Unrestricted |
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9
3.2.2.6 Community Facilities – Public Amenities
| Sl. | Use Types | Ground Coverage (%) | Road Width (m) | Base FAR | Max. FAR |
| 1(a) | Marriage Hall/ Banquet/ Multipurpose Hall/ Religious Building (Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2.0 | 4.0 |
| Marriage Hall/ Banquet/ Multipurpose Hall/ Religious Building (Built up) | Max. coverage after ensuring setbacks | >24 - 45m | 2.0 | 7.0 | |
| Marriage Hall/ Banquet/ Multipurpose Hall/ Religious Building (Built up) | Max. coverage after ensuring setbacks | More than 45m | 2.0 | Unrestricted | |
| 1(b) | Marriage Hall/ Banquet/ Multipurpose Hall/ Religious Building (Non-Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 3.0 | 6.0 |
| 1(b) | Marriage Hall/ Banquet/ Multipurpose Hall/ Religious Building (Non-Built up) | Max. coverage after ensuring setbacks | =>24 - 45m | 3.0 | 10.5 |
| 1(b) | Marriage Hall/ Banquet/ Multipurpose Hall/ Religious Building (Non-Built up) | Max. coverage after ensuring setbacks | More than 45m | 3.0 | Unrestricted |
| 2 (a) | Auditorium / Convention Centre (Built-up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2.0 | 4.0 |
| 2 (a) | Auditorium / Convention Centre (Built-up) | Max. coverage after ensuring setbacks | >24 - 45m | 2.0 | 7.0 |
| 2 (a) | Auditorium / Convention Centre (Built-up) | Max. coverage after ensuring setbacks | More than 45m | 2.0 | Unrestricted |
| 2 (b) | =>24 - 45m | 3.0 | 10.5 | ||
| Sl. | Use Types | Ground Coverage (%) | Road Width (m) | Base FAR | Max. FAR |
| Auditorium / Convention Centre (Non-built-up area) | Max. coverage after ensuring setbacks | More than 45m | 3.0 | Unrestricted | |
| 3 | Guest House | Max. coverage after ensuring setbacks | =>12 - 24m | 1.5 | 3.0 |
| 3 | Guest House | Max. coverage after ensuring setbacks | >24 - 45m | 1.5 | 5.25 |
3.2.2.7 Other Uses
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9
| Sl. | Use Types | Ground Coverage (%) | Road width (m) | Base FAR | Max. FAR |
| Agriculture | |||||
| 1 | Farmhouse | 20% for non-farm activities | =>7 | 0.2 | 0.2 |
| 2 | Dairy Farms | 20% | =>7 | 0.2 | 0.2 |
| Industrial | |||||
| 1 | Industrial Buildings | Max. coverage after ensuring setbacks | Up to 12m | 1.5 | 1.5 |
| 1 | Industrial Buildings | Max. coverage after ensuring setbacks | >12 - 24 m | 2.5 | 5.0 |
| 1 | Industrial Buildings | Max. coverage after ensuring setbacks | >24 - 45 m | 2.5 | 8.75 |
| 1 | Industrial Buildings | Max. coverage after ensuring setbacks | > 45 m | 2.5 | Unrestricted |
| 2 | Flatted factories/ MSME | Max. coverage after ensuring setbacks | Up to 12m | 3.0 | 3.0 |
| 2 | Flatted factories/ MSME | Max. coverage after ensuring setbacks | >12 - 24 m | 3.0 | 6.0 |
| 2 | Flatted factories/ MSME | Max. coverage after ensuring setbacks | >24 - 45 m | 3.0 | 9.0 |
| 2 | Flatted factories/ MSME | Max. coverage after ensuring setbacks | > 45 m | 3.0 | Unrestricted |
| 3 | Data Centers | Max. coverage after ensuring setbacks | Up to 12m | 3.0 | 3.0 |
| 3 | Data Centers | Max. coverage after ensuring setbacks | >12 - 24 m | 3.0 | 6.0 |
| 3 | Data Centers | Max. coverage after ensuring setbacks | >24 - 45 m | 3.0 | 9.0 |
| 3 | Data Centers | Max. coverage after ensuring setbacks | > 45 m | 3.0 | Unrestricted |
| Mixed Use | As per 8.1 | As per 8.1 | As per 8.1 | As per 8.1 | |
| Recreational | |||||
| 1 | Stadium/ Sports Complex | 20% |
3.2.2.8 Exemptions from FAR calculations
| Sl. | Q: Is the structure included in FAR calculation? Key: Y= Yes, included in calculation N = No, not included in calculation NA = Not permitted thus not applicable | t i n u-ilMtu/legn<sup>i</sup>S-<sup>l</sup>i<sup>a</sup> <sup>t</sup>n diees R | g n <sup>i</sup>H<sup>sou</sup> poru G-<sup>l</sup>i<sup>a</sup> <sup>t</sup>n diees R | U<sup>es</sup> diex M/l<sub>i</sub><sup>a</sup>c e<sup>r</sup> mmo C | s <sup>g</sup>n <sup>i</sup>d <sup>l</sup><sub>i</sub>u B iffec O | l <sup>a</sup>n i<sup>o</sup> <sub>i</sub><sup>t</sup><sub>tt</sub>s<sup>u</sup> I<sup>n</sup> | l i<sup>a</sup> dtrsu I<sup>n</sup> | hter O |
|---|---|---|---|---|---|---|---|---|
| 1 | Mezzanine | Y | Y | Y | Y | Y | Y | Y |
| 2 | Pergola (if closed from three or more sides) | Y | Y | Y | Y | Y | Y | Y |
| 3a | Lift Machine Room | N | N | N | N | N | N | N |
| 3b | Lift Shafts (to be counted as covered area only once i.e. on ground floor) | Y | Y | Y | Y | Y | Y | Y |
| 3c | Lift Lobby up to 10 square meters | N | N | N | N | N | N | N |
| 4 | Meter Room (as per electricity authority norms) | N | N | N | N | N | N | N |
| 5 | Cantilever projection at any level (in setbacks) 0.75m width (no construction of any type or any material shall be permitted over projections) | N | N | N | N | N | N | N |
| 6 | Porch/ Portico (Maximum 4-meter x 8 meter). It shall not interfere with Fire tender movement. | Y | Y | Y | Y | Y | Y | Y |
| 7 | Basement(s) within the setback line, if used for: | |||||||
| 7a | Parking lot and garages | N | N | N | N | N | N | N |
| 7b | Air conditioning equipment and other machines | N | N | N | N | N | N | N |
| 7c | DG set room, meter room and electric panel room, Effluent Treatment Plant, suction tank, pump room |
The maximum building height for various use occupancies shall be as follows.
| Sl. | Use Occupancies | Max. Building Height (m) |
|---|---|---|
| I | Residential (Built-up/ Non-Built-up) | |
| 1 | Plotted - Single-Unit | 15 |
| 2 | Plotted - Multi-unit | 17.5 |
| 3 | Group Housing | No Restriction |
| II | Commercial | |
| 1 | Shops / Convenient Shopping / Commercial Units | No Restriction |
| 2 | Commercial Complex | No Restriction |
| 3 | Shopping mall | No Restriction |
| 4 | Hotels | No Restriction |
| 5 | Single screen cinema/ Miniplex/ Multiplex | No Restriction |
| 6 | Petrol Pump / Filling Station | 6 |
| t7 | LPG / Gas Go down | 6 |
| III | Community Facilities | |
| A | Healthcare Buildings | |
| 1 | Non-Bedded Medical Establishments (Diagnostic Centre / OPD clinics / dispensary / Pathology Lab / Veterinary Clinics) | No Restriction |
| 2 | Nursing Homes / Veterinary Hospitals / Maternity Hospitals / Small Hospitals (Up to 50 beds) | No Restriction |
| 3 | Hospitals (> 50 beds) | No Restriction |
| 4 | Nursing Institutes | No Restriction |
| 5 | Medical College | No Restriction |
| B | Educational Buildings | No Restriction |
| 1 | Nursery | No Restriction |
| 2 | Primary | No Restriction |
| 3 | High School | No Restriction |
| 4 | Technical Institution | No Restriction |
| 5 | Universities | No Restriction |
| C | Public Amenity buildings | |
| 1 | Marriage / Festival Hall | No Restriction |
| 2 | Auditorium / Convention Centre | No Restriction |
| IV | Agriculture | |
| 1 | Farmhouse | No restriction |
| 2 | Dairy Farms | No restriction |
| V | Industrial | |
| 1 | Industrial buildings | No Restriction |
| 2 | Flatted factories | No Restriction |
| 3 | Data Centers | No Restriction |
| VI | Mixed Use | No Restriction |
| VII | Recreational | |
| 1 | Stadium/ Sports Complex | No Restriction |
| 2 | Amusement Park | No Restriction |
| 3 | Memorial | No Restriction |
| VIII | Transportation | |
| 1 | Multi-level Parking | No Restriction |
| 2 | Bus Terminal | No Restriction |
| 3 | Transportation Hub | No Restriction |
Note:
(i) The maximum height of buildings shall be measured above the surrounding average road level and following supporting structures shall not be included in the height of the building: -
(ii) Rooftop tanks and their supporting structures not exceeding 2.0 m in height, rooftop structures required to capture alternative solar energy, ventilation, air conditioning equipment, lift rooms not exceeding 4.5 m in height and such other service equipment, ladders covered by mumty slab and not exceeding 3.0 m in height. Chimney, parapet wall and structures for enhancing the aesthetics of the building which are not more than 1.5 m height provided the total area of such structures including the ‘barsati’ do not exceed one third of the area of the roof of the building
on which it is constructed.
(iii) The height of buildings adjacent to the aerodrome/air-force stations shall be in accordance with the orders issued by the Government of India/ Ministry of Civil Aviation/ Ministry of Defence, Airport Authority of India, from time to time.
(iv) The maximum height of the building shall also be governed by the distance from the protected monument / heritage site, airport funnel zone and other statutory restrictions.
| 2 |
| Unrestricted |
| 6(b) | Hotels (Non-Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2.5 | 5 |
| >24 - 45m | 2.5 | 8.75 |
| > 45m | 2.5 | Unrestricted |
| 7 (a) | Single Screen Cinema (Built-up/Non-built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 |
| > 45m | 2 | Unrestricted |
| 7(b) | Miniplex (Built-up/Non-built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 |
| > 45m | 2 | Unrestricted |
| 7(c) | Multiplex (Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 |
| > 45m | 2 | Unrestricted |
| 7(d) | Multiplex (Non-Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 3 | 6 |
| >24 - 45m | 3 | 9 |
| > 45m | 3 | Unrestricted |
| 8(a) | Petrol Filling Station w/o service station (Built up) | 10% | =>12m | 0.1 | - |
| 8(b) | Petrol Filling Station w/o service station (Non Built up) | 10% | =>24m | 0.15 |
| 8(c) | Petrol Filling Station with service station (Built up) | 20% | =>12m | 0.2 | - |
| 8(d) | Petrol Filling Station with service station (Non-Built up) | 10% | =>24m | 0.1 |
| 9 | LPG / Gas Go down | 25% | =>18m | 0.25 | 0.25 |
| 10(a) | Service Apartment (Built-up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 |
| > 45m | 2 | Unrestricted |
| 10(b) | Service Apartment (Non-Built up) | Max. coverage after ensuring setbacks | =>12 - 24m | 2.5 | 5 |
| >24 - 45m | 2.5 | 8.75 |
| > 45m | 2.5 | Unrestricted |
| 11 | Cold Storage | 18m |
| 12(a) | Storage/Warehousing (Built up) | Max. coverage after ensuring setbacks | 12m | 0.8 | 0.8 |
| 12(b) | Storage/Warehousing (Non-Built up) | Max. coverage after ensuring setbacks | 12m | 1.2 | 1.2 |
| 13 | Fruit & Vegetable Market | Max. coverage after ensuring setbacks | 12m | 1 | 1 |
| 14(a) | Wholesale Business (Built) | Max. coverage after ensuring setbacks | 12m | 1.2 | 1.2 |
| 14(b) | Wholesale Business (Non-Built) | Max. coverage after ensuring setbacks | 12m | 1.5 | 1.5 |
| 15(a) | Office Buildings (Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2 | 4 |
| >24 - 45m | 2 | 7 |
| > 45m | 2 | Unrestricted |
| 15(b) | Office Buildings (Non-Built up) | Max. coverage after ensuring setbacks | =>18 - 24m | 2.5 | 5 |
| >24 - 45m | 2.5 | 8.75 |
| > 45m | 2.5 | Unrestricted |
| 16(a) | Other Commercial (Built up) | Max. coverage after ensuring setbacks | Up to 12m | 1.5 | 2.1 |
| >12 - 24m | 1.5 | 3.0 |
| >24 - 45m | 1.5 | 5.0 |
| >45m | 1.5 | Unrestricted |
| 16(b) | Other Commercial (Non-Built) | Max. coverage after ensuring setbacks | =>12 -24m | 1.75 | 3.5 |
| >24 -45m | 1.75 | 6.0 |
| >45m | 1.75 | Unrestricted |
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9
| Unrestricted |
| 6(a) | Medical College (Built up) | Max. coverage after ensuring setbacks | =>24 - 45m | 1.5 | 5.25 |
| > 45m | 1.5 | Unrestricted |
| 6(b) | Medical College (Non-Built up) | Max. coverage after ensuring setbacks | =>24 - 45m | 2.5 | 8.75 |
| > 45m | 2.5 | Unrestricted |
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9
| 3 |
| Guest House |
| Max. coverage after ensuring setbacks |
| More than 45m |
| 1.5 |
| Unrestricted |
| 4 | Utilities & Services | 10% | 0.1 |
| 5 | Other institutional/ PSP | =>12 - 24m | 2.0 | 4.0 |
| 5 | Other institutional/ PSP | >24 - 45m | 2.0 | 7.0 |
| 5 | Other institutional/ PSP | More than 45m | 2.0 | Unrestricted |
| 12m |
| 0.4 |
| 0.4 |
| 2 | Amusement Park | 20% | 12m | 1.0 | 1.0 |
| Transportation |
| Sl. | Use Types | Ground Coverage (%) | Road width (m) | Base FAR | Max. FAR |
| 1 | Multi-level Parking/ Bus Terminal/ Transportation Hub | Max. coverage after ensuring setbacks | =>12 - 24 m | 1.5 | 3.0 |
| >24 - 45 m | 1.5 | 5.25 |
| > 45 m | 1.5 | Unrestricted |
| Parks and Open Spaces |
| Open spaces (Built-up area) | 5% | 0.1* |
| Open spaces (Non-Built-up area) | 5% | 0.1* |
Note: Maximum Permissible FAR (MFAR) is calculated as per the provisions of purchasable FAR in Chapter-9 *Note: Only for ancillary use.
| N |
| N |
| N |
| N |
| N |
| N |
| N |
| 7d | Storage of household goods or other goods or ordinarily non-combustible material incidental to principal use | N | N | N | N | N | N | N |
| 7e | Storage not incidental to principal use. | Y | Y | Y | Y | Y | Y | Y |
| 7f | Non-combustible storage rooms (stacking rooms) of libraries | Y | Y | Y | Y | Y | Y | Y |
| 7g | Strong rooms, bank lockers, safe deposit vaults, laundry room, radio/laser therapy, post-mortem room, mortuary, medical shop and cold storage for hospital building etc. | Y | Y | Y | Y | Y | Y | Y |
| 7h | Offices and commercial uses (if air-conditioned) | Y | Y | Y | Y | Y | Y | Y |
| 7i | Commercial use in first basement in case of shopping center/ shopping malls. | Y | Y | Y | Y | Y | Y | Y |
| Sl. | Q: Is the structure included in FAR calculation? Key: Y= Yes, included in calculation N = No, not included in calculation NA = Not permitted thus not applicable | t i n u-ilMtu/legn<sup>i</sup>S-<sup>l</sup>i<sup>a</sup> <sup>t</sup>n diees R | g n <sup>i</sup>H<sup>sou</sup> poru G-<sup>l</sup>i<sup>a</sup> <sup>t</sup>n diees R | U<sup>es</sup> diex M/l<sub>i</sub><sup>a</sup>c e<sup>r</sup> <sup>m</sup><sub>m</sub>o C | s <sup>g</sup>n <sup>i</sup>d <sup>l</sup><sub>i</sub>u B iffec O | l <sup>a</sup>n i<sup>o</sup> <sub>i</sub><sup>t</sup><sub>tt</sub>s<sup>u</sup> I<sup>n</sup> | l i<sup>a</sup> dtrsu I<sup>n</sup> | hter O |
| 7j | Nursing quarters as ancillary use to hospital in first basement, if proper ventilation is ensured. | Y | Y | Y | Y | Y | Y | Y |
| 7k | Any other use related to ancillary use, e.g. toilets, if proper requirements of lighting, ventilation and fire safety are adhered to | Y | Y | Y | Y | Y | Y | Y |
| 7l | In mixed use buildings, uses other than ancillary uses shall also be allowed after meeting lighting, ventilation and fire safety requirements. | Y | Y | Y | Y | Y | Y | Y |
| 8a | Stilt floor used for parking | N | N | N | N | N | N | N |
| 8b | Stilt Floor used for any purpose other than parking | Y | Y | Y | Y | Y | Y | Y |
| 9 | Podium Parking (with max. 10% of permissible land cover utilized for Driver Restroom, Store, Sanitary Block and other similar services) | N | N | N | N | N | N | N |
| 10 | Separate Parking Block for Plot Area above 4000 sqm. | N | N | N | N | N | N | N |
| 11 | Locked Garages in Rear Setback | N | Y | Y | Y | Y | Y | Y |
| 12a | Balconies up to 2.0 metres | N | N | Y | Y | Y | Y | Y |
| 12b | Balconies beyond 2.0 metres | Y | Y | Y | Y | Y | Y | Y |
| 13a | Staircase | Y | Y | Y | Y | Y | Y | Y |
| 13b | Fire Escape/ External Staircase | N | N | N | N | N | N | N |
| 14 | Planters and Sun Control Devices | N | N | N | N | N | N | N |
| 15 | Jali of any material to cover AC/cooler units | N | N | N | N | N | N | N |
| 16 | Rockery, well & well structures, water pool, uncovered swimming pool, tree platform, tank, fountain, bench, open-top & unenclosed chabutra, compound wall, gate, slide, swing, underground water tanks, overhead water tanks on top of buildings, open shafts, culverts on drain | N | N | N | N | N | N | N |
| 17 | Open ramps with no area enclosed below it of usable height. If used for approach to the entrance of the building, then the height as per requirement may be considered. The space under the ramp shall not be used for any commercial purpose, however it can be landscaped with approval of the Authority on case-to-case basis. | N | N | N | N | N | N | N |
| 18 | Open ramps for movement of vehicles in side setback only | N | N | N | N | N | N | N |
| 19a | Atriums in Commercial/ Office & PSP above 3000 sqm Plot Area | NA | NA | N | N | N | NA | NA |
| 19b | Temporary Counters maximum up to 20% of the area of Atrium | NA | NA | N | N | N | NA | NA |
| 20 | Service Floors (max. up to 3 floors), allowed on every 4<sup>th</sup> floor in a multistorey building | NA | NA | N | N | N | N | N |
| 21 | Any other feature purely ornamental in nature and not enclosing or covering space of commercial use may be permitted by Vice Chairman on case-to-case basis. | NA | N | N | N | N | N | N |
| 22 | Loft up to 30% of room area (max. 1.5 metre height) | N | N | N | N | N | N | N |
| 23 | Mumty | N | N | N | N | N | N | N |
| 24 | Bay Windows and Almirahs/ Niche | N | N | N | N | N | N | N |
| 25 | Refuge Area (As per fire norms) | N | N | N | N | N | N | N |
| Sl. | Q: Is the structure included in FAR calculation? Key: Y= Yes, included in calculation N = No, not included in calculation NA = Not permitted thus not applicable | t i n u-ilMtu/legn<sup>i</sup>S-<sup>l</sup>i<sup>a</sup> <sup>t</sup>n diees R | g n <sup>i</sup>H<sup>sou</sup> poru G-<sup>l</sup>i<sup>a</sup> <sup>t</sup>n diees R | U<sup>es</sup> diex M/l<sub>i</sub><sup>a</sup>c e<sup>r</sup> <sup>m</sup><sub>m</sub>o C | s <sup>g</sup>n <sup>i</sup>d <sup>l</sup><sub>i</sub>u B iffec O | l <sup>a</sup>n i<sup>o</sup> <sub>i</sub><sup>t</sup><sub>tt</sub>s<sup>u</sup> I<sup>n</sup> | l i<sup>a</sup> dtrsu I<sup>n</sup> | hter O |
| 26 | Service Duct | N | N | N | N | N | N | N |
| 27 | Services such as air conditioning equipment and other machines, DG set room, meter room and electric panel room, Effluent Treatment Plant, suction tank, pump room - maximum up to 5% of permissible FAR or 50sqm (incase of Plot Area <= 4000 sqm) / 100 sqm (in case of Plot Area > 4000 sqm) | N | N | N | N | N | N | N |
Note: A maximum of 5.0 percent of the permissible FAR shall be availed for various types of services like airconditioned plants, in front of the lift (except corridor outside the lift), up to10 square meters shall be allowed for lobby, machine room for lift, Mumty, shelves and windows (maximum 0.60-meter depth and 1.80-meters length), refuse area (as per NBC), service duct and community centre.