4.3.1 Requirements
For all housing projects (except affordable housing schemes) having more than one unit, a 10% each of the total units shall be mandatorily reserved for Economically Weaker Section (EWS) and Lower Income Group (LIG) housing respectively. For plots less than 4 Ha, provision to deposit shelter fee shall be applicable.
4.3.2 Eligibility of EWS and LIG
Eligibility of EWS and LIG shall be determined based on annual income limit. For being eligible under EWS, the current limit is an annual income of rupees 3 lakhs and for being eligible under LIG, the current limit is an annual income of rupees 3-6 lakhs or as amended by State Government as per the guidelines issued from time to time.
4.3.3 Minimum Plot Size
The minimum plot size for EWS and LIG housing (in plotted development) and minimum carpet area (in group housing) shall be as follows.
| EWS | LIG | |
|---|---|---|
| Plotted (Plot size in sqm) | =>35 - 40 | >40 - 50 |
| Group Housing (Carpet area in sqm) | =>30 - 35 | >35 - 45 |
4.3.4 Means of Access
For EWS and LIG housing in plotted development, the minimum width of the access road shall be 4.0 meters in built-up areas and 6-meters in in non-built-up areas. For EWS and LIG housing in group housing, the minimum width of the access road shall be 9.0 meters.
4.3.5 Ground Coverage and FAR
(i) After ensuring minimum setback and mandatory open space requirements, maximum ground coverage shall be permissible on plotted development and group housing.
(ii) The maximum permissible FAR for EWS and LIG housing in plotted development shall be 2.0.
(iii) The maximum permissible FAR for EWS and LIG housing in group housing shall be the same as in paragraph 4.2.8. The FAR consumed in mandatory EWS/LIG units in group housing shall not be counted in the overall FAR which can be consumed in the rest of the scheme.
(iv) For plots less than 4 Ha, in case EWS/LIG plots/units are not constructed and shelter fee is deposited, then in lieu of the same, equivalent FAR in proportion to the number of units corresponding to which the shelter fee has been deposited can be consumed in the rest of the scheme.
4.3.6 Minimum Setback
The minimum setbacks for EWS and LIG housing in plotted development and group housing shall be as per paragraph 3.2.4 of the building byelaws.
4.3.7 Maximum Building Height
(i) For plotted development, the maximum height of the building shall be 17.5 meters including stilt floor for multi-unit. Construction of stilts and three floors shall be permissible. Further, the height of a residential building in plotted development shall be governed by its distance from the protected monument/ heritage site, airport funnel zone and other statutory restrictions, if any.
(ii) For EWS and LIG in group housing scheme, there shall be no restriction on building height in non-built-up area, however, in built-up area the maximum building height shall be 17.5 meters. However, the height of the building in group housing project shall be governed by its distance from the protected monument/heritage site, airport funnel zone and other statutory restrictions if any.
4.3.8 Parking Requirements
(i) The parking requirements for EWS and LIG housing shall be as follows.
| EWS | LIG |
|---|---|
| 2.0 sqm / DU | 4.0 sqm / DU |
(ii) In both group housing and plotted development projects, stilts shall be permissible for parking arrangements as per paragraph 3.3.4 of the building byelaws, which shall not be counted in FAR. Only open parking shall be allowed on stilts, if covered parking is made (covered on more than two sides), it shall be counted in FAR.
(iii) For plots of area above 4000 sqm, a separate block for parking is permissible, within the plot. Within the parking block, 10% of ground floor may be utilized for ancillary purposes (free from FAR) incidental to the principal use.
(iv) If separate parking block is built above the ground level, then the distance between the main building and seperate parking block shall be the minimum setback required as per the height of
the highest block or 6-meters whichever is higher.
4.3.9 Basement
The permissibility of basement for EWS and LIG in plotted development and group housing scheme shall be as per paragraph 3.3.3 of the building byelaws.
4.3.10 Cost Ceiling of Buildings
The ceiling cost of EWS and LIG units shall be as below:
| Category | Ceiling Cost |
|---|---|
| EWS | Rs. 4,50,000/- |
| LIG | Rs. 9,00,000/- |
For cities with more than 10 lakh population, the ceiling cost may be enhanced by 20 percent.
The above ceiling cost as amended by the state government from to time shall prevail.
4.3.11 Calculation of Shelter Fee
The shelter fee payable shall be calculated according to the following formula.
Shelter Fees =
10% of [(total number of dwelling units) X (minimum EWS dwelling unit carpet area + minimum LIG dwelling unit carpet area) X Circle Rate]