The objective of design is the achievement of an acceptable probability that structures will perform
satisfactorily for the intended purpose during the design life. With an appropriate degree of safety, they should sustain all the loads and deformations, during construction and use and have adequate resistance to certain expected accidental loads and fire. Structure should be stable and have alternate load paths to prevent disproportionate overall collapse under accidental loading.
9.1.2 Methods of Design
9.1.2.1 Structure and its elements shall normally, be designed by the limit state method. Account should be taken of accepted theories, experimental information and experience and the need to design for durability. Calculations alone may not produce safe, serviceable and durable structures. Suitable materials, quality control, adequate detailing and good supervision are equally important.
9.1.2.2 Where the limit states method cannot be conveniently adopted; the working stress design [see Section 6(m)] may be used.
9.1.3 Design Process
Structural design, including design for durability, construction and use should be considered as a whole. The realization of design objectives requires compliance with clearly defined standards for materials, fabrication, erection and in-service maintenance.
9.2Loads and Forces
9.2.1 For the purpose of designing any element, member or a structure, the following loads (actions) and their effects shall be taken into account, where applicable, with partial safety factors and combinations (see 11.3.3).
f) Accidental loads such as those due to blast, impact of vehicles, etc; and
g) Secondary effects due to contraction or expansion resulting from temperature changes, differential settlements of the structure as a whole or of its components, eccentric connections, rigidity of joints differing from design assumptions.
9.2.1.1 Dead loads should be assumed in design as specified in 2 of Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’ of the Code.
PART 6 STRUCTURAL DESIGN — SECTION 6 STEEL
Table 1Tensile Properties of Structural Steel Products (Clauses 2.113, 2.119 and 8.2.4.2)
Sl No.
Accepted Standard
Grade / Classification
Properties
Yield Stress MPa Min (4)
Ultimate Tensile Stress MPa Min (5)
Elongation Percent Min (6)
(1)
(2)
(3)
i)
[6-6(24)]
O
—
—
—
D
280
270-410
28
DD
250
270-370
32
EDD
220
270-350
35
ii)
[6-6(18)]
Ex40xx
330
410-540
16
Ex41xx
330
410-540
20
Ex42xx
330
410-540
22
Ex43xx
330
410-540
24
Ex44xx
330
410-540
24
Ex50xx
360
510-610
16
Ex51xx
360
510-610
18
Ex52xx
360
510-610
18
Ex53xx
360
510-610
20
Ex54xx
360
510-610
20
Ex55xx
360
510-610
20
Ex56xx
360
510-610
20
iii)
[6-6(25)]
O
—
—
—
D
—
240-400
25
DD
—
260-390
28
EDD
—
260-380
32
iv)
[6-6(26)]
3.6
180
330
25
4.6
240
400
22
4.8
320
420
—
5.6
300
500
20
5.8
400
520
—
6.8
480
600
—
8.8(d≤16mm)
6401)
800
12
8.8(d>16mm)
6601)
830
12
9.8
7201)
900
10
10.9
9401)
1040
9
12.9
11001)
1220
8
v)
[6-6(27)]
1
200
370
26
1A
220
410
25
2
230
430
24
2A
250
460
22
3
270
490
21
3A
280
540
20
4
320
620
15
5
350
710
13
6
370
740
10
vi)
[6-6(28)]
S137S142
≤20220250>20200240
360-440
26
410-500
23
t
t
t
≤16
>16 and ≤40
>40 and ≤60
>60 and ≤100
>100 and ≤350
≤60
>60 and ≤350
vii)
[6-6(29)]
1
235
225
215
200
185
360-480
360-480
350-480
2
265
255
245
215
200
410-530
410-530
400-530
3
290
285
280
255
230
460-580
450-570
440-570
Table 1 — (Concluded)
(1)
(2)
(3)
(4)
(5)
(6)
d or t
<20
20-40
>40
410
23
E250 (A, BR, B0, C)
250
240
230
430
22
viii)
[6-6(6)]
E275 (A, BR, B0, C)
275
265
255
440
22
E300 (A, BR, B0, C)
300
290
280
490
22
E350 (A, BR, B0, C)
350
330
320
540
20
E410 (A, BR, B0, C)
410
390
380
570
20
E450 (A, BR)
450
430
420
d or t
≤ 25
>25 and ≤ 50
ix)
[6-6(30)]
I
230
220
400-490
22
II
235
235
400-490
22
III
235
235
400-490
22
x)
[6-6(31)]
Grade 1
240
350-450
25
Grade 2
245
360-450
34
xi)
[6-6(10)]
Annealed Condition
160
330 - 410
30
As-Drawn Condition
190
410 - 490
20
xii)
[6-6(32)]
HFC 210/CDS 210/ERW210
210
330
20
HFC 240/CDS 240/ERW240
240
410
18
HFC 310/CDS 310/ERW310
310
450
15
xiii)
[6-6(33)]
1
170
290
30
2
210
330
28
3
240
410
25
4
275
430
20
5
310
490
15
NOTES
1 Percentage of elongation shall be taken over the gauge length of 5.65 S0 , where S0 = original cross-sectional area of the test specimen.2 Abbreviations: O = Ordinary, D = Drawing, DD = Deep Drawing, EDD = Extra Deep Drawing.
1) Stress at 0.2 percent non-proportional elongation, Min.
9.2.1.2 Imposed loads for different types of occupancy and function of structures shall be taken as recommended in 3 of Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’ of the Code. Imposed loads arising from equipment, such as cranes and machines should be assumed in design as per manufacturers/suppliers data (see 9.5.4). Snow load shall be taken as per in 6 of Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’ of the Code.
9.2.1.3 Wind loads on structures shall be taken as per the provisions of 4 of Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’ of the Code.
9.2.1.3.1 Wind pressure
In calculating the effective wind pressure on exposed circular tube members of a structure, the effective area
shall be taken as 0.6 times the projected area of the member (see 4 of Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’).
9.2.1.4 Earthquake loads shall be assumed as per the recommendations of 5 of Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’ of the Code.
9.2.1.5 The erection loads and temperature effects shall be considered as specified in 9.3 and 9.4, respectively.
9.3Erection Loads
All loads required to be carried by the structure or any part of it due to storage or positioning of construction material and erection equipment, including all loads due to operation of such equipment shall be considered as erection loads. Proper provision shall be made,
PART 6 STRUCTURAL DESIGN — SECTION 6 STEEL
including temporary bracings, to take care of all stresses developed during erection. Dead load, wind load and also such parts of the imposed load as would be imposed on the structure during the period of erection shall be taken as acting together with the erection loads. The structure as a whole and all parts of the structure in conjunction with the temporary bracings shall be capable of sustaining these loads during erection.