13.1.1 Common hot rolled and built-up steel members used for carrying axial compression, usually fail by
flexural buckling. The buckling strength of these members is affected by residual stresses, initial bow and accidental eccentricities of load. To account for all these factors, the strength of members subjected to axial compression is defined by buckling class a, b, c, or d as given Table 7.
13.1.2 The factored design compression, P in members shall satisfy the following requirement:
∣P<Pd∣
where
Pd=Aefcd
where
Ae = effective sectional area as defined in 13.3.2, and
fcd = design compressive stress, obtained as per 13.1.2.1.
13.1.2.1 The design compressive strength, fcd of axially loaded compression members shall be calculated using the following equation:
fcd=ϕ+[ϕ2−λ2]0.5fy/γm0=χfy/γm0≤fy/γm0
where
ϕ=0.5[1+α(λ−0.2)+λ2]
λ= non-dimensional effective slenderness ratio
=fy/fcc=fy(rKL)2/π2E
fcc=Euler buckling stress=(KL/r)2π2E
where
KL/r = effective slenderness ratio or ratio of effective length, KL to appropriate radius of gyration, r;
α = imperfection factor given in Table 7;
χ = stress reduction factor (see Table 8) for different buckling class, slenderness ratio and yield stress
=[ϕ+(ϕ2−λ2)0.5]1
γm0 = partial safety factor for material strength.
NOTE — Calculated values of design compressive stress, fcd for different buckling classes are given in Table 9.
13.1.2.2 The classification of different sections under different buckling class a, b, c or d, is given in Table 10.
The stress reduction factor χ , and the design compressive stress fcd , for different buckling class, yield stress, and effective slenderness ratio is given in Table 8 for convenience. The curves corresponding to different buckling class are presented in non-dimensional form, in Fig. 8.
Table 7 Imperfection Factor, α
(Clauses 13.1.1 and 13.1.2.1)
Buckling Class(1)
a(2)
b(3)
c(4)
d(5)
α
0.21
0.34
0.49
0.76
13.2Effective Length of Compression Members
13.2.1 The effective length KL, is calculated from the actual length L, of the member, considering the rotational and relative translational boundary conditions at the ends. The actual length shall be taken as the length from centre-to-centre of its intersections with the supporting members in the plane of the buckling deformation. In the case of a member with a free end, the free standing length from the centre of the intersecting member at the supported end, shall be taken as the actual length.
13.2.2 Effective Length
Where the boundary conditions in the plane of buckling can be assessed, the effective length, KL can be calculated on the basis of Table 11. Where frame analysis does not consider the equilibrium of a framed structure in the deformed shape (second-order analysis
or advanced analysis), the effective length of compression members in such cases can be calculated using the procedure given in C-1. The effective length of stepped column in single storey buildings can be calculated using the procedure given in C-2.
13.2.3 Eccentric Beam Connection
In cases where the beam connections are eccentric in plan with respect to the axes of the column, the same conditions of restraint as in concentric connection shall be deemed to apply, provided the connections are carried across the flange or web of the columns as the case may be, and the web of the beam lies within, or in direct contact with the column section. Where practical difficulties prevent this, the effective length shall be taken as equal to the distance between points of restraint, in non-sway frames.
13.2.4 Compression Members in Trusses
In the case of bolted, riveted or welded trusses and braced frames, the effective length, KL, of the compression members shall be taken as 0.7 to 1.0 times the distance between centres of connections, depending on the degree of end restraint provided. In the case of members of trusses, buckling in the plane perpendicular to the plane of the truss, the effective length, KL shall be taken as the distance between the centers of intersection. The design of angle struts shall be as specified in 13.5.
13.3Design Details
13.3.1 Thickness of Plate Elements
Classification of members on the basis of thickness of
FIG. 8 COLUMN BUCKLING CURVES
PART 6 STRUCTURAL DESIGN — SECTION 6 STEEL
Table 8(a) Stress Reduction Factor, \chi for Column Buckling Class a (Clauses 13.1.2.1 and 13.1.2.2)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
20
1.000
0.999
0.998
0.997
0.995
0.994
0.993
0.993
0.990
0.988
0.986
0.984
0.983
0.981
0.979
0.977
0.975
0.972
0.970
30
0.977
0.975
0.974
0.972
0.970
0.969
0.967
0.965
0.961
0.957
0.954
0.951
0.948
0.946
0.943
0.938
0.934
0.930
0.925
40
0.952
0.949
0.947
0.944
0.942
0.939
0.937
0.934
0.926
0.921
0.916
0.911
0.906
0.901
0.896
0.888
0.881
0.873
0.865
50
0.923
0.919
0.915
0.911
0.908
0.904
0.900
0.896
0.884
0.876
0.867
0.859
0.851
0.842
0.834
0.820
0.807
0.794
0.780
60
0.888
0.883
0.877
0.871
0.865
0.859
0.853
0.847
0.828
0.816
0.803
0.790
0.777
0.763
0.750
0.730
0.710
0.690
0.671
70
0.846
0.837
0.829
0.820
0.811
0.803
0.794
0.785
0.758
0.740
0.722
0.703
0.686
0.668
0.651
0.626
0.602
0.579
0.557
80
0.793
0.781
0.769
0.757
0.746
0.734
0.722
0.710
0.675
0.653
0.631
0.610
0.589
0.570
0.551
0.525
0.501
0.478
0.458
90
0.730
0.715
0.700
0.685
0.671
0.657
0.643
0.628
0.590
0.565
0.542
0.520
0.500
0.481
0.463
0.439
0.416
0.396
0.377
100
0.661
0.644
0.627
0.610
0.594
0.579
0.564
0.549
0.510
0.486
0.463
0.443
0.424
0.407
0.390
0.368
0.348
0.331
0.314
110
0.591
0.573
0.555
0.538
0.522
0.507
0.492
0.478
0.440
0.418
0.397
0.379
0.362
0.346
0.332
0.312
0.295
0.279
0.265
120
0.525
0.507
0.489
0.473
0.458
0.443
0.429
0.416
0.381
0.361
0.343
0.326
0.311
0.297
0.284
0.267
0.252
0.238
0.226
130
0.466
0.448
0.432
0.416
0.402
0.388
0.376
0.364
0.332
0.314
0.298
0.283
0.269
0.257
0.246
0.231
0.217
0.206
0.195
140
0.413
0.397
0.382
0.368
0.355
0.342
0.331
0.320
0.291
0.275
0.260
0.247
0.235
0.224
0.214
0.201
0.189
0.179
0.170
150
0.368
0.353
0.339
0.326
0.314
0.303
0.293
0.283
0.257
0.243
0.229
0.218
0.207
0.197
0.189
0.177
0.166
0.157
0.149
160
0.329
0.316
0.303
0.291
0.280
0.270
0.261
0.252
0.229
0.215
0.204
0.193
0.184
0.175
0.167
0.157
0.147
0.139
0.132
170
0.296
0.283
0.272
0.261
0.251
0.242
0.233
0.225
0.204
0.192
0.182
0.172
0.164
0.156
0.149
0.140
0.131
0.124
0.117
180
0.267
0.255
0.245
0.235
0.226
0.218
0.210
0.203
0.184
0.173
0.163
0.155
0.147
0.140
0.134
0.125
0.118
0.111
0.105
190
0.242
0.231
0.222
0.213
0.205
0.197
0.190
0.183
0.166
0.156
0.147
0.140
0.133
0.126
0.121
0.113
0.106
0.100
0.095
200
0.220
0.210
0.202
0.193
0.186
0.179
0.172
0.166
0.151
0.142
0.134
0.127
0.120
0.115
0.109
0.102
0.096
0.091
0.086
210
0.201
0.192
0.184
0.177
0.170
0.163
0.157
0.152
0.137
0.129
0.122
0.115
0.110
0.104
0.099
0.093
0.087
0.083
0.078
220
0.184
0.176
0.169
0.162
0.155
0.149
0.144
0.139
0.126
0.118
0.111
0.106
0.100
0.095
0.091
0.085
0.080
0.075
0.071
230
0.170
0.162
0.155
0.149
0.143
0.137
0.132
0.128
0.115
0.108
0.102
0.097
0.092
0.088
0.083
0.078
0.073
0.069
0.065
240
0.157
0.149
0.143
0.137
0.132
0.127
0.122
0.118
0.106
0.100
0.094
0.089
0.085
0.081
0.077
0.072
0.068
0.064
0.060
250
0.145
0.138
0.132
0.127
0.122
0.117
0.113
0.109
0.098
0.092
0.087
0.082
0.078
0.074
0.071
0.066
0.062
0.059
0.056
Table 8(b) Stress Reduction Factor, \chi for Column Buckling Class b (Clauses 13.1.2.1 and 13.1.2.2)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
20
1.000
0.998
0.996
0.994
0.993
0.991
0.990
0.986
0.983
0.981
0.978
0.975
0.972
0.970
0.967
0.963
0.960
0.956
0.953
30
0.963
0.961
0.958
0.955
0.953
0.950
0.948
0.943
0.938
0.933
0.929
0.924
0.920
0.915
0.911
0.904
0.898
0.892
0.886
40
0.925
0.921
0.917
0.913
0.909
0.906
0.902
0.895
0.887
0.880
0.873
0.866
0.859
0.852
0.845
0.835
0.825
0.815
0.805
50
0.883
0.877
0.872
0.866
0.861
0.855
0.850
0.839
0.829
0.818
0.808
0.798
0.787
0.777
0.767
0.752
0.737
0.722
0.708
60
0.835
0.827
0.820
0.812
0.805
0.798
0.790
0.775
0.761
0.746
0.732
0.718
0.704
0.691
0.677
0.657
0.638
0.620
0.602
70
0.781
0.771
0.761
0.751
0.742
0.732
0.722
0.703
0.685
0.667
0.649
0.632
0.615
0.599
0.584
0.561
0.540
0.520
0.502
80
0.721
0.709
0.697
0.685
0.673
0.661
0.650
0.627
0.606
0.585
0.566
0.547
0.529
0.512
0.496
0.474
0.453
0.434
0.416
90
0.657
0.643
0.629
0.615
0.602
0.589
0.576
0.552
0.530
0.508
0.488
0.470
0.452
0.436
0.421
0.400
0.380
0.363
0.346
100
0.593
0.577
0.562
0.548
0.534
0.520
0.507
0.483
0.461
0.440
0.421
0.403
0.387
0.372
0.358
0.339
0.321
0.306
0.291
110
0.531
0.515
0.500
0.485
0.471
0.458
0.445
0.422
0.401
0.381
0.364
0.348
0.333
0.319
0.306
0.289
0.274
0.260
0.247
120
0.474
0.458
0.443
0.429
0.416
0.403
0.391
0.370
0.350
0.332
0.316
0.301
0.288
0.276
0.265
0.249
0.236
0.223
0.212
130
0.423
0.408
0.394
0.380
0.368
0.356
0.345
0.325
0.307
0.291
0.276
0.263
0.251
0.240
0.230
0.217
0.204
0.194
0.184
140
0.378
0.364
0.350
0.338
0.327
0.316
0.306
0.287
0.271
0.256
0.243
0.231
0.221
0.211
0.202
0.190
0.179
0.169
0.161
150
0.339
0.325
0.313
0.302
0.291
0.281
0.272
0.255
0.241
0.227
0.215
0.205
0.195
0.186
0.178
0.167
0.158
0.149
0.142
160
0.305
0.292
0.281
0.271
0.261
0.252
0.243
0.228
0.215
0.203
0.192
0.182
0.174
0.166
0.158
0.149
0.140
0.133
0.126
170
0.275
0.264
0.253
0.244
0.235
0.227
0.219
0.205
0.193
0.182
0.172
0.163
0.155
0.148
0.142
0.133
0.125
0.118
0.112
180
0.249
0.239
0.229
0.220
0.212
0.205
0.198
0.185
0.174
0.164
0.155
0.147
0.140
0.133
0.128
0.120
0.113
0.106
0.101
190
0.227
0.217
0.208
0.200
0.193
0.186
0.179
0.168
0.157
0.148
0.140
0.133
0.127
0.121
0.115
0.108
0.102
0.096
0.091
200
0.207
0.198
0.190
0.183
0.176
0.169
0.163
0.153
0.143
0.135
0.128
0.121
0.115
0.110
0.105
0.098
0.092
0.087
0.083
210
0.190
0.182
0.174
0.167
0.161
0.155
0.149
0.140
0.131
0.123
0.117
0.110
0.105
0.100
0.096
0.090
0.084
0.080
0.075
220
0.174
0.167
0.160
0.154
0.148
0.142
0.137
0.128
0.120
0.113
0.107
0.101
0.096
0.092
0.088
0.082
0.077
0.073
0.069
230
0.161
0.154
0.147
0.141
0.136
0.131
0.126
0.118
0.111
0.104
0.098
0.093
0.088
0.084
0.080
0.075
0.071
0.067
0.063
240
0.149
0.142
0.136
0.131
0.126
0.121
0.117
0.109
0.102
0.096
0.091
0.086
0.082
0.078
0.074
0.070
0.065
0.062
0.058
250
0.138
0.132
0.126
0.121
0.117
0.112
0.108
0.101
0.095
0.089
0.084
0.080
0.076
0.072
0.069
0.064
0.060
0.057
0.054
Table 8(c) Stress Reduction Factor, \chi for Column Buckling Class c (Clauses 13.1.2.1 and 13.1.2.2)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
20
0.999
0.997
0.994
0.992
0.990
0.987
0.985
0.981
0.976
0.972
0.968
0.964
0.961
0.957
0.953
0.948
0.943
0.938
0.933
30
0.948
0.944
0.941
0.937
0.933
0.930
0.926
0.920
0.913
0.907
0.901
0.895
0.889
0.883
0.877
0.869
0.861
0.853
0.845
40
0.896
0.891
0.885
0.880
0.875
0.870
0.866
0.856
0.847
0.838
0.829
0.820
0.812
0.803
0.795
0.783
0.771
0.760
0.748
50
0.841
0.834
0.827
0.821
0.814
0.807
0.801
0.788
0.776
0.763
0.752
0.740
0.729
0.717
0.706
0.690
0.675
0.660
0.645
60
0.783
0.774
0.765
0.757
0.748
0.740
0.732
0.716
0.700
0.685
0.670
0.656
0.642
0.628
0.615
0.596
0.578
0.561
0.544
70
0.722
0.711
0.700
0.690
0.680
0.670
0.660
0.641
0.623
0.605
0.588
0.572
0.557
0.542
0.528
0.508
0.489
0.471
0.454
80
0.659
0.646
0.634
0.622
0.611
0.600
0.589
0.568
0.548
0.529
0.512
0.495
0.479
0.464
0.450
0.430
0.412
0.395
0.379
90
0.596
0.583
0.569
0.557
0.544
0.533
0.521
0.499
0.479
0.460
0.443
0.426
0.411
0.397
0.383
0.365
0.348
0.332
0.318
100
0.536
0.522
0.508
0.495
0.483
0.471
0.459
0.438
0.418
0.400
0.384
0.368
0.354
0.341
0.328
0.311
0.296
0.282
0.269
110
0.480
0.466
0.453
0.440
0.428
0.416
0.405
0.385
0.366
0.349
0.333
0.319
0.306
0.294
0.283
0.268
0.254
0.242
0.230
120
0.430
0.416
0.403
0.391
0.379
0.368
0.358
0.339
0.321
0.306
0.291
0.278
0.267
0.256
0.246
0.232
0.220
0.209
0.199
130
0.385
0.372
0.360
0.348
0.337
0.327
0.317
0.299
0.283
0.269
0.256
0.244
0.234
0.224
0.215
0.203
0.192
0.182
0.173
140
0.346
0.333
0.322
0.311
0.301
0.291
0.282
0.266
0.251
0.238
0.227
0.216
0.206
0.197
0.189
0.178
0.168
0.160
0.152
150
0.311
0.300
0.289
0.279
0.269
0.261
0.252
0.237
0.224
0.212
0.202
0.192
0.183
0.175
0.168
0.158
0.149
0.141
0.134
160
0.281
0.270
0.260
0.251
0.242
0.234
0.227
0.213
0.201
0.190
0.180
0.172
0.164
0.156
0.150
0.141
0.133
0.126
0.120
170
0.255
0.245
0.236
0.227
0.219
0.212
0.205
0.192
0.181
0.171
0.162
0.154
0.147
0.140
0.134
0.126
0.119
0.113
0.107
180
0.232
0.223
0.214
0.206
0.199
0.192
0.186
0.174
0.164
0.155
0.147
0.139
0.133
0.127
0.121
0.114
0.107
0.102
0.096
190
0.212
0.203
0.195
0.188
0.181
0.175
0.169
0.158
0.149
0.140
0.133
0.126
0.120
0.115
0.110
0.103
0.097
0.092
0.087
200
0.194
0.186
0.179
0.172
0.166
0.160
0.154
0.144
0.136
0.128
0.121
0.115
0.110
0.105
0.100
0.094
0.089
0.084
0.079
210
0.178
0.171
0.164
0.158
0.152
0.146
0.141
0.132
0.124
0.117
0.111
0.105
0.100
0.096
0.092
0.086
0.081
0.076
0.072
220
0.164
0.157
0.151
0.145
0.140
0.135
0.130
0.122
0.114
0.108
0.102
0.097
0.092
0.088
0.084
0.079
0.074
0.070
0.066
230
0.152
0.145
0.140
0.134
0.129
0.124
0.120
0.112
0.105
0.099
0.094
0.089
0.085
0.081
0.077
0.073
0.068
0.065
0.061
240
0.141
0.135
0.129
0.124
0.120
0.115
0.111
0.104
0.098
0.092
0.087
0.082
0.078
0.075
0.071
0.067
0.063
0.060
0.056
250
0.131
0.125
0.120
0.115
0.111
0.107
0.103
0.096
0.090
0.085
0.081
0.076
0.073
0.069
0.066
0.062
0.058
0.055
0.052
Table 8(d) Stress Reduction Factor, \chi for Column Buckling Class d (Clauses 13.1.2.1 and 13.1.2.2)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
20
0.999
0.995
0.991
0.988
0.984
0.980
0.977
0.970
0.964
0.958
0.952
0.946
0.940
0.935
0.930
0.922
0.915
0.908
0.901
30
0.922
0.916
0.911
0.906
0.901
0.896
0.891
0.881
0.872
0.863
0.855
0.847
0.839
0.831
0.823
0.813
0.802
0.792
0.782
40
0.848
0.841
0.834
0.828
0.821
0.815
0.808
0.796
0.784
0.773
0.762
0.751
0.741
0.731
0.721
0.707
0.694
0.681
0.668
50
0.777
0.768
0.760
0.752
0.744
0.736
0.728
0.713
0.699
0.685
0.672
0.659
0.647
0.635
0.624
0.608
0.592
0.577
0.563
60
0.707
0.697
0.687
0.678
0.668
0.659
0.651
0.634
0.617
0.602
0.587
0.573
0.560
0.547
0.535
0.517
0.501
0.486
0.471
70
0.640
0.629
0.618
0.607
0.597
0.587
0.578
0.559
0.542
0.526
0.510
0.496
0.482
0.469
0.456
0.439
0.423
0.408
0.394
80
0.576
0.564
0.553
0.542
0.531
0.521
0.511
0.492
0.474
0.458
0.442
0.428
0.414
0.402
0.390
0.373
0.358
0.344
0.330
90
0.517
0.505
0.493
0.482
0.471
0.461
0.451
0.432
0.415
0.399
0.384
0.370
0.357
0.345
0.334
0.319
0.304
0.292
0.280
100
0.464
0.451
0.440
0.428
0.418
0.408
0.398
0.380
0.363
0.348
0.334
0.321
0.309
0.298
0.288
0.274
0.261
0.249
0.239
110
0.416
0.404
0.392
0.381
0.371
0.361
0.352
0.335
0.319
0.305
0.292
0.281
0.270
0.259
0.250
0.237
0.226
0.215
0.206
120
0.373
0.361
0.350
0.340
0.330
0.321
0.313
0.297
0.282
0.269
0.257
0.246
0.236
0.227
0.219
0.207
0.197
0.187
0.179
130
0.336
0.325
0.314
0.305
0.295
0.287
0.279
0.264
0.251
0.239
0.228
0.218
0.209
0.200
0.193
0.182
0.173
0.164
0.157
140
0.303
0.292
0.283
0.274
0.265
0.257
0.250
0.236
0.224
0.213
0.203
0.194
0.185
0.178
0.171
0.161
0.153
0.145
0.138
150
0.274
0.264
0.255
0.247
0.239
0.231
0.224
0.212
0.201
0.190
0.181
0.173
0.165
0.159
0.152
0.144
0.136
0.129
0.123
160
0.249
0.240
0.231
0.223
0.216
0.209
0.203
0.191
0.181
0.171
0.163
0.155
0.149
0.142
0.137
0.129
0.122
0.116
0.110
170
0.227
0.218
0.210
0.203
0.196
0.190
0.184
0.173
0.164
0.155
0.147
0.140
0.134
0.128
0.123
0.116
0.110
0.104
0.099
180
0.207
0.199
0.192
0.185
0.179
0.173
0.167
0.157
0.149
0.141
0.134
0.127
0.122
0.116
0.111
0.105
0.099
0.094
0.089
190
0.190
0.183
0.176
0.169
0.164
0.158
0.153
0.144
0.136
0.128
0.122
0.116
0.111
0.106
0.101
0.095
0.090
0.085
0.081
200
0.175
0.168
0.162
0.156
0.150
0.145
0.140
0.132
0.124
0.118
0.112
0.106
0.101
0.097
0.093
0.087
0.082
0.078
0.074
210
0.161
0.155
0.149
0.143
0.138
0.134
0.129
0.121
0.114
0.108
0.102
0.097
0.093
0.089
0.085
0.080
0.075
0.071
0.068
220
0.149
0.143
0.138
0.133
0.128
0.123
0.119
0.112
0.105
0.100
0.094
0.090
0.086
0.082
0.078
0.074
0.069
0.066
0.062
230
0.138
0.133
0.128
0.123
0.118
0.114
0.110
0.104
0.097
0.092
0.087
0.083
0.079
0.075
0.072
0.068
0.064
0.061
0.058
240
0.129
0.123
0.119
0.114
0.110
0.106
0.103
0.096
0.090
0.085
0.081
0.077
0.073
0.070
0.067
0.063
0.059
0.056
0.053
250
0.120
0.115
0.110
0.106
0.102
0.099
0.095
0.089
0.084
0.079
0.075
0.071
0.068
0.065
0.062
0.058
0.055
0.052
0.049
PART 6 STRUCTURAL DESIGN — SECTION 6 STEEL
Table 9(a) Design Compressive Stress, f_{\mathrm{cd}} (MPa) For Column Buckling Class a (Clause 13.1.2.1)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
182
191
200
213
218
227
236
255
273
291
309
327
345
364
382
409
436
464
491
20
182
191
200
208
217
226
235
252
270
287
305
322
339
357
374
400
425
451
476
30
178
186
195
203
212
220
229
245
262
279
295
311
328
344
360
384
408
431
454
40
173
181
189
197
205
213
221
237
253
268
283
298
313
328
342
363
384
405
425
50
168
176
183
191
198
205
213
227
241
255
268
281
294
306
318
336
352
368
383
60
162
169
175
182
189
195
202
214
226
237
248
258
268
278
286
299
310
320
329
70
154
160
166
171
177
182
188
197
207
215
223
230
237
243
249
256
263
268
274
80
144
149
154
158
163
167
171
178
184
190
195
199
204
207
210
215
219
222
225
90
133
137
140
143
146
149
152
157
161
164
168
170
173
175
177
179
182
184
185
100
120
123
125
128
130
132
133
136
139
141
143
145
146
148
149
151
152
153
154
110
107
109
111
112
114
115
116
118
120
121
123
124
125
126
127
128
129
129
130
120
95.5
96.7
97.9
98.9
100
101
101
103
104
105
106
107
107
108
109
109
110
110
111
130
84.6
85.5
86.3
87
87.7
88.3
88.8
89.8
90.6
91.3
92.0
92.5
93.0
93.5
93.9
94.4
94.9
95.3
95.7
140
75.2
75.8
76.4
76.9
77.4
77.8
78.2
78.9
79.5
80.0
80.5
80.9
81.3
81.6
81.9
82.3
82.6
83.0
83.2
150
67.0
67.4
67.9
68.2
68.6
68.9
69.2
69.7
70.2
70.6
70.9
71.2
71.5
71.8
72.0
72.3
72.6
72.9
73.1
160
59.9
60.3
60.6
60.9
61.1
61.4
61.6
62.0
62.4
62.7
62.9
63.2
63.4
63.6
63.8
64.0
64.3
64.5
64.6
170
53.8
54.1
54.3
54.6
54.8
55.0
55.1
55.5
55.7
56.0
56.2
56.4
56.6
56.7
56.9
57.1
57.3
57.4
57.6
180
48.6
48.8
49.0
49.2
49.3
49.5
49.6
49.9
50.1
50.3
50.5
50.6
50.8
50.9
51.0
51.2
51.3
51.5
51.6
190
44.0
44.2
44.3
44.5
44.6
44.7
44.9
45.1
45.3
45.4
45.6
45.7
45.8
45.9
46.0
46.2
46.3
46.4
46.5
200
40.0
40.2
40.3
40.4
40.5
40.7
40.7
40.9
41.1
41.2
41.3
41.4
41.5
41.6
41.7
41.8
41.9
42.0
42.1
210
36.6
36.7
36.8
36.9
37.0
37.1
37.2
37.3
37.4
37.6
37.7
37.8
37.8
37.9
38.0
38.1
38.2
38.3
38.3
220
33.5
33.6
33.7
33.8
33.9
34.0
34.0
34.2
34.3
34.4
34.5
34.5
34.6
34.7
34.7
34.8
34.9
35.0
35.0
230
30.8
30.9
31.0
31.1
31.2
31.2
31.3
31.4
31.5
31.6
31.6
31.7
31.8
31.8
31.9
31.9
32.0
32.1
32.1
240
28.5
28.5
28.6
28.7
28.7
28.8
28.8
28.9
29.0
29.1
29.1
29.2
29.3
29.3
29.4
29.4
29.5
29.5
29.6
250
26.3
26.4
26.5
26.5
26.6
26.6
26.7
26.7
26.8
26.9
26.9
27.0
27.0
27.1
27.1
27.2
27.2
27.3
27.3
Table 9(b) Design Compressive Stress, f_{\mathrm{cd}} (MPa) for Column Buckling Class b (Clause 13.1.2.1)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
182
191
200
209
218
227
236
255
273
291
309
327
345
364
382
409
436
464
491
20
182
190
199
208
217
225
234
251
268
285
302
319
336
353
369
394
419
443
468
30
175
183
192
200
208
216
224
240
256
271
287
302
318
333
348
370
392
414
435
40
168
176
183
191
198
206
213
228
242
256
270
283
297
310
323
342
360
378
395
50
161
167
174
181
188
194
201
214
226
238
250
261
272
283
293
308
322
335
347
60
152
158
164
170
176
181
187
197
207
217
226
235
243
251
259
269
279
287
295
70
142
147
152
157
162
166
171
179
187
194
201
207
213
218
223
230
236
241
246
80
131
135
139
143
147
150
154
160
165
170
175
179
183
186
190
194
198
201
204
90
120
123
126
129
131
134
136
141
144
148
151
154
156
159
161
163
166
168
170
100
108
110
112
114
116
118
120
123
126
128
130
132
134
135
137
139
140
142
143
110
96.5
98.3
100
101
103
104
105
107
109
111
112
114
115
116
117
118
119
121
121
120
86.2
87.5
88.6
89.7
90.7
91.7
92.5
94.1
95.4
96.6
97.7
98.6
100
100
101
102
103
104
104
130
76.9
77.8
78.7
79.5
80.3
81.0
81.6
82.7
83.7
84.6
85.4
86.1
86.8
87.3
87.9
88.6
89.2
89.8
90.3
140
68.7
69.4
70.1
70.7
71.3
71.8
72.3
73.1
73.9
74.6
75.2
75.7
76.2
76.6
77.1
77.6
78.1
78.5
78.9
150
61.6
62.1
62.6
63.1
63.6
64.0
64.3
65.0
65.6
66.1
66.6
67.0
67.4
67.7
68.1
68.5
68.9
69.2
69.5
160
55.4
55.8
56.2
56.6
56.9
57.3
57.5
58.1
58.5
59.0
59.3
59.7
60.0
60.3
60.5
60.9
61.2
61.5
61.7
170
50.0
50.3
50.7
51.0
51.2
51.5
51.7
52.2
52.5
52.9
53.2
53.5
53.7
53.9
54.1
54.4
54.7
54.9
55.1
180
45.3
45.6
45.9
46.1
46.3
46.5
46.7
47.1
47.4
47.7
47.9
48.1
48.3
48.5
48.7
48.9
49.2
49.3
49.5
190
41.2
41.5
41.7
41.9
42.1
42.2
42.4
42.7
42.9
43.2
43.4
43.6
43.7
43.9
44.0
44.2
44.4
44.6
44.7
200
37.6
37.8
38.0
38.2
38.3
38.5
38.6
38.9
39.1
39.3
39.5
39.6
39.8
39.9
40.0
40.2
40.3
40.5
40.6
210
34.5
34.7
34.8
35.0
35.1
35.2
35.3
35.5
35.7
35.9
36.0
36.2
36.3
36.4
36.5
36.6
36.8
36.9
37.0
220
31.7
31.9
32.0
32.1
32.2
32.3
32.4
32.6
32.8
32.9
33.0
33.1
33.2
33.3
33.4
33.6
33.7
33.8
33.9
230
29.2
29.4
29.5
29.6
29.7
29.8
29.9
30.0
30.1
30.3
30.4
30.5
30.6
30.7
30.7
30.8
30.9
31.0
31.1
240
27.1
27.2
27.3
27.3
27.4
27.5
27.6
27.7
27.8
27.9
28.0
28.1
28.2
28.3
28.3
28.4
28.5
28.6
28.7
250
25.1
25.2
25.3
25.3
25.4
25.5
25.6
25.7
25.8
25.9
26.0
26.0
26.1
26.2
26.2
26.3
26.4
26.5
26.5
Table 9(c) Design Compressive Stress, f_{\mathrm{cd}} (MPa) for Column Buckling Class c (Clause 13.1.2.1)
KL/r
Yield Stress, fy , (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
182
191
200
209
218
227
236
255
273
291
309
327
345
364
382
409
436
464
491
20
182
190
199
207
216
224
233
250
266
283
299
316
332
348
364
388
412
435
458
30
172
180
188
196
204
211
219
234
249
264
278
293
307
321
335
355
376
395
415
40
163
170
177
184
191
198
205
218
231
244
256
268
280
292
304
320
337
352
367
50
153
159
165
172
178
183
189
201
212
222
232
242
252
261
270
282
295
306
317
60
142
148
153
158
163
168
173
182
191
199
207
215
222
228
235
244
252
260
267
70
131
136
140
144
148
152
156
163
170
176
182
187
192
197
202
208
213
218
223
80
120
123
127
130
133
136
139
145
149
154
158
162
165
169
172
176
180
183
186
90
108
111
114
116
119
121
123
127
131
134
137
140
142
144
146
149
152
154
156
100
97.5
100
102
104
105
107
109
112
114
116
119
120
122
124
125
127
129
131
132
110
87.3
89.0
90.5
92.0
93.3
94.6
95.7
97.9
100
102
103
104
106
107
108
110
111
112
113
120
78.2
79.4
80.6
81.7
82.7
83.7
84.6
86.2
87.6
88.9
90.1
91.1
92.1
93.0
93.8
94.9
95.9
96.8
97.6
130
70.0
71.0
71.9
72.8
73.5
74.3
75.0
76.2
77.3
78.3
79.2
80.0
80.7
81.4
82.0
82.9
83.6
84.3
84.9
140
62.9
63.6
64.4
65.0
65.6
66.2
66.7
67.7
68.6
69.3
70.0
70.7
71.2
71.8
72.3
72.9
73.5
74.1
74.6
150
56.6
57.2
57.8
58.3
58.8
59.2
59.7
60.4
61.1
61.7
62.3
62.8
63.3
63.7
64.1
64.6
65.1
65.5
65.9
160
51.1
51.6
52.1
52.5
52.9
53.3
53.6
54.2
54.8
55.3
55.7
56.1
56.5
56.9
57.2
57.6
58.0
58.4
58.7
170
46.4
46.8
47.1
47.5
47.8
48.1
48.4
48.9
49.3
49.8
50.1
50.5
50.8
51.1
51.3
51.7
52.0
52.3
52.6
180
42.2
42.5
42.8
43.1
43.4
43.6
43.9
44.3
44.7
45.0
45.3
45.6
45.8
46.1
46.3
46.6
46.9
47.1
47.3
190
38.5
38.8
39.0
39.3
39.5
39.7
39.9
40.3
40.6
40.9
41.1
41.4
41.6
41.8
42.0
42.2
42.5
42.7
42.9
200
35.3
35.5
35.7
35.9
36.1
36.3
36.5
36.8
37.0
37.3
37.5
37.7
37.9
38.1
38.2
38.4
38.6
38.8
39.0
210
32.4
32.6
32.8
33.0
33.1
33.3
33.4
33.7
33.9
34.1
34.3
34.5
34.7
34.8
34.9
35.1
35.3
35.4
35.6
220
29.9
30.1
30.2
30.4
30.5
30.6
30.8
31.0
31.2
31.4
31.5
31.7
31.8
31.9
32.1
32.2
32.4
32.5
32.6
230
27.6
27.8
27.9
28.0
28.2
28.3
28.4
28.6
28.8
28.9
29.1
29.2
29.3
29.4
29.5
29.7
29.8
29.9
30.0
240
25.6
25.7
25.9
26.0
26.1
26.2
26.3
26.4
26.6
26.7
26.9
27.0
27.1
27.2
27.3
27.4
27.5
27.6
27.7
250
23.8
23.9
24.0
24.1
24.2
24.3
24.4
24.5
24.7
24.8
24.9
25.0
25.1
25.2
25.3
25.4
25.5
25.6
25.7
Table 9(d) Design Compressive Stress, f_{\mathrm{cd}} (MPa) for Column Buckling Class d (Clause 13.1.2.1)
KL/r
Yield Stress, fy (MPa)
↓
200
210
220
230
240
250
260
280
300
320
340
360
380
400
420
450
480
510
540
10
182
191
200
209
218
227
236
255
273
291
309
327
345
364
382
409
436
464
491
20
182
190
198
206
215
223
231
247
263
279
294
310
325
340
355
377
399
421
442
30
168
175
182
189
197
204
211
224
238
251
264
277
290
302
314
332
350
367
384
40
154
161
167
173
179
185
191
203
214
225
235
246
256
266
275
289
303
316
328
50
141
147
152
157
162
167
172
182
191
199
208
216
224
231
238
249
258
268
277
60
129
133
137
142
146
150
154
161
168
175
182
188
193
199
204
212
219
225
231
70
116
120
124
127
130
133
137
142
148
153
158
162
167
171
174
180
184
189
193
80
105
108
111
113
116
118
121
125
129
133
137
140
143
146
149
153
156
159
162
90
94.1
96.4
98.6
101
103
105
107
110
113
116
119
121
123
126
128
130
133
135
137
100
84.3
86.2
87.9
89.6
91.1
92.6
94.0
96.7
99.1
101
103
105
107
108
110
112
114
116
117
110
75.6
77.0
78.4
79.7
81.0
82.1
83.2
85.3
87.1
88.8
90.4
91.8
93.1
94.4
95.5
97.1
98.5
100
101
120
67.8
69.0
70.1
71.1
72.1
73.0
73.9
75.5
77.0
78.3
79.5
80.6
81.7
82.6
83.5
84.7
85.8
86.9
87.8
130
61.0
62.0
62.8
63.7
64.5
65.2
65.9
67.2
68.3
69.4
70.4
71.2
72.1
72.8
73.5
74.5
75.4
76.2
76.9
140
55.0
55.8
56.5
57.2
57.8
58.4
59.0
60.0
61.0
61.8
62.6
63.3
64.0
64.6
65.2
66.0
66.7
67.3
67.9
150
49.8
50.4
51.0
51.6
52.1
52.6
53.1
53.9
54.7
55.4
56.0
56.6
57.2
57.7
58.1
58.8
59.3
59.9
60.4
160
45.2
45.7
46.2
46.7
47.1
47.5
47.9
48.6
49.3
49.9
50.4
50.9
51.3
51.7
52.1
52.7
53.1
53.6
54.0
170
41.2
41.6
42.1
42.4
42.8
43.1
43.5
44.1
44.6
45.1
45.5
45.9
46.3
46.7
47.0
47.4
47.8
48.2
48.6
180
37.7
38.0
38.4
38.7
39.0
39.3
39.6
40.1
40.5
41.0
41.3
41.7
42.0
42.3
42.6
43.0
43.3
43.6
43.9
190
34.5
34.9
35.2
35.4
35.7
35.9
36.2
36.6
37.0
37.4
37.7
38.0
38.2
38.5
38.7
39.1
39.4
39.6
39.9
200
31.8
32.0
32.3
32.5
32.8
33.0
33.2
33.6
33.9
34.2
34.5
34.7
35.0
35.2
35.4
35.7
35.9
36.2
36.4
210
29.3
29.6
29.8
30.0
30.2
30.4
30.5
30.9
31.2
31.4
31.7
31.9
32.1
32.3
32.5
32.7
32.9
33.1
33.3
220
27.1
27.3
27.5
27.7
27.9
28.0
28.2
28.5
28.7
29.0
29.2
29.4
29.6
29.7
29.9
30.1
30.3
30.5
30.6
230
25.2
25.3
25.5
25.7
25.8
26.0
26.1
26.4
26.6
26.8
27.0
27.1
27.3
27.5
27.6
27.8
27.9
28.1
28.2
240
23.4
23.6
23.7
23.9
24.0
24.1
24.2
24.5
24.7
24.8
25.0
25.2
25.3
25.4
25.5
25.7
25.9
26.0
26.1
250
21.8
22.0
22.1
22.2
22.3
22.5
22.6
22.8
22.9
23.1
23.2
23.4
23.5
23.6
23.7
23.9
24.0
24.1
24.2
PART 6 STRUCTURAL DESIGN — SECTION 6 STEEL
Table 10Buckling Class of Cross-Sections (Clause 13.1.2.2)
Cross-Section(1)
Limits(2)
Buckling About Axis(3)
Buckling Class(4)
Rolled I-SectionsI-y
h/bf>1.2:tf≤40mm40mm<tf≤100mm
z−zy−yz−zy−y
a b b c
h/bf≤1.2:tf≤100mmtf>100mm
z−zy−yz−zy−y
b c d d
Welded I-Section
tf≤40mmtf>40mm
z−zy−yz−zy−y
b c c d
Hollow Section
Hot rolled
Any
a
Cold formed
Any
b
Welded Box Section
Generally(except as below)
Any
b
Thick welds and b/tf<30h/tw<30
z−zy−y
c c
Channel, Angle, T and Solid Sections
Any
b
Built-up Member
Any
c
Table 11Effective Length of Prismatic Compression Members (Clause 13.2.2)
Boundary Conditions
Schematic Representation
Effective Length
At One End
At the Other End
Translation(1)
Rotation(2)
Translation(3)
Rotation(4)
(5)
(6)
Restrained
Restrained
Free
Free
1
2.0L
Restrained
Free
Free
Restrained
Restrained
Free
Restrained
Free
1.0L
Restrained
Restrained
Free
Restrained
1.2L
Restrained
Restrained
Restrained
Free
0.8L
Restrained
Restrained
Restrained
Restrained
0.65L
NOTE — L is the unsupported length of the compression member (see 13.2.1).
PART 6 STRUCTURAL DESIGN — SECTION 6 STEEL
constituent plate elements shall satisfy the width-thickness ratio requirements specified in Table 2.
13.3.2 Effective Sectional Area, A{mathrm{e}}
Except as modified in 9.7.2 (Class 4), the gross sectional area shall be taken as the effective sectional area for all compression members fabricated by welding, bolting and riveting so long as the section is semi-compact or better. Holes not fitted with rivets, bolts or pins shall be deducted from gross area to calculate effective sectional area.
13.3.3Eccentricity for Stanchions and Columns
13.3.3.1 For the purpose of determining the stress in a stanchion or column section, the beam reactions or similar loads shall be assumed to be applied at an eccentricity of 100 mm from the face of the section or at the center of bearing whichever dimension gives the greater eccentricity, and with the exception of the following two cases:
a) In the case of cap connection, the load shall be assumed to be applied at the face of the column or stanchion section or at the edge of packing, if used towards the span of the beam.
b) In the case of a roof truss bearing on a cap, no eccentricity be taken for simple bearings without connections capable of developing any appreciable moment. In case of web member connection with face, actual eccentricity is to be considered.
13.3.3.2 In continuous columns, the bending moments due to eccentricities of loading on the columns at any floor may be divided equally between the columns above and below that floor level, provided that the moment of inertia of one column section, divided by its effective length does not exceed 1.5 times the corresponding value of the other column. Where this ratio is exceeded, the bending moment shall be divided in proportion to the moment of inertia of the column sections divided by their respective effective lengths.
13.3.4Splices
13.3.4.1 Where the ends of compression members are prepared for bearing over the whole area, they shall be spliced to hold the connected members accurately in position, and to resist bending or tension, if present. Such splices should maintain the intended member stiffness about each axis. Splices should be located as close to the point of inflection as possible. Otherwise their capacity should be adequate to carry magnified moment (see 15.3.2.2). The ends of compression members faced for bearing shall invariably be machined to ensure perfect contact of surfaces in bearing.
13.3.4.2 Where such members are not faced for complete bearing, the splices shall be designed to transmit all the forces to which the members are subjected.
13.3.4.3 Wherever possible, splices shall be proportioned and arranged so that the centroidal axis of the splice coincides as nearly as possible with the centroidal axes of the members being jointed, in order
to avoid eccentricity; but where eccentricity is present in the joint, the resulting stress shall be accounted for.
13.4Column Bases
13.4.1 General
Column bases should have sufficient stiffness and strength to transmit axial force, bending moments and shear forces at the base of the columns to their foundation without exceeding the load carrying capacity of the supports. Anchor bolts and shear keys should be provided wherever necessary. Shear resistance at the proper contact surface between steel base and concrete/grout may be calculated using a friction coefficient of 0.45.
The nominal bearing pressure between the base plate and the support below may be determined on the basis of linearly varying distribution of pressure. The maximum bearing pressure on concrete under the limit states design load should not exceed the bearing strength
equal to 0.45fck[(A1/A2)] and 0.9fck, whichever is smaller, where fck is the smaller of characteristic cube strength of concrete or bedding material, A1 is the area of concrete pedestal on which the base plate is sitting, and A2 is the surface area of the steel base plate transferring the load to the concrete pedestal.
13.4.1.1 If the size of the base plate is larger than that required to limit the bearing pressure on the base support, an equal projection c of the base plate beyond the face of the column and gusset may be taken as effective in transferring the column load as given in Fig. 9, such that bearing pressure on the effective area does not exceed bearing capacity of concrete base.
13.4.2 Gusseted Bases
For stanchion with gusseted bases, the gusset plates, angle cleats, stiffeners, fastenings, etc, in combination with the bearing area of the shaft, shall be sufficient to take the loads, bending moments and reactions to the base plate without exceeding specified strength. All the bearing surfaces shall be machined to ensure perfect contact.
13.4.2.1 Where the ends of the column shaft and the gusset plates are not faced for complete bearing, the welds, fastenings connecting them to the base plate shall be sufficient to transmit all the forces to which the base is subjected.
13.4.2.2 Column and base plate connections
Where the end of the column is connected directly to the base plate by means of full penetration butt welds, the connection shall be deemed to transmit to the base all the forces and moments to which the column is subjected.
13.4.3 Slab Bases
Columns with slab bases need not be provided with gussets, but sufficient fastenings shall be provided to retain the parts securely in place and to resist all moments and forces, other than direct compression, including those arising during transit, unloading and erection.
13.4.3.1 The minimum thickness, ts, of rectangular slab bases, supporting columns under axial compression shall be:
ts=2.5w(a2−0.3b2)γm0/fy>tf
where
w = uniform pressure from below on the slab base under the factored load axial compression;
a, b = larger and smaller projection, respectively of the slab base beyond the rectangle circumscribing the column; and
tf= flange thickness of compression member.
When only the effective area of the base plate is used as in 13.4.1.1, c2 may be used in the above equation (see Fig. 9) instead of (a2−0.3b2).
13.4.3.2 When the slab does not distribute the column load uniformly, due to eccentricity of the load etc, special calculation shall be made to show that the base is adequate to resist the moment due to the non-uniform pressure from below.
13.4.3.3 Bases for bearing upon concrete or masonry need not be machined on the underside.
13.4.3.4 In cases where the cap or base is fillet welded directly to the end of the column without boring and shouldering, the contact surfaces shall be machined to give a perfect bearing and the welding shall be sufficient to transmit the forces as required in 13.4.3. Where full strength butt welds are provided, machining of contact surfaces is not required.